DistributorSouthwire

Service Wire

VFD JACKETED MC (ACWU90) RHW-2/CPE 2,000 Volt Copper

Service Wire #
SW-SERVICE-DRIVE-MC-2KV-CPE

Three copper conductors, stranded and insulated with heat and moisture resistant, chemically crosslinked polyethylene (type RHW-2) , phase identified and cabled together with suitable fillers and three symmetrical bare copper ground conductors. Cable core shielded with 5-mil copper tape, helically applied with 50% overlap for 100% coverage and double tape thickness throughout the cable. Shielded core covered with galvanized steel interlocked armor with overall black CPE jacket. Available with aluminum armor or PVC or EnviroPlus ® (LSZH) jacket. Available with 50% grounds*.

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (18) ↓

Available sizes & constructions

Size (AWG or Kcmil)(AWG or Kcmil)Strand (no.)(no.)Insulation Thickness (mils)(mm)Grounding Conductors (AWG)(AWG)Diameter Over Armor (in.)(mm)Jacket Thickness (mils)(mm)Approx. Diameter Overall (in.)(mm)Approx. Net Weight (lb./1000')(kg/km)Ampacity (30°C ambient) 90°C Wet/Dry
14†14†77601.52(3) #14(3) #140.6316.0501.270.7318.53765602525 VFD2KGC14/3
12†12†77601.52(3) #14(3) #140.6717.0501.270.7719.64266343030 VFD2KGC12/3
10†10†77601.52(3) #14(3) #140.7318.5501.270.8321.14967384040 VFD2KGC10/3
8†8†77802.03(3) #14(3) #140.8722.1501.270.9724.66589795555 VFD2KGC8/3
6677802.03(3) #12(3) #120.9524.1501.271.0526.78361,2447575 VFD2KGC6/3
4477802.03(3) #12(3) #121.0727.2501.271.1729.71,0641,5839595 VFD2KGC4/3
3377802.03(3) #10(3) #101.1128.2501.271.2130.71,2341,836110110 VFD2KGC3/3
2277802.03(3) #10(3) #101.2331.2501.271.3333.81,4162,107130130 VFD2KGC2/3
111919952.41(3) #10(3) #101.3734.8501.271.4737.31,8062,688150150 VFD2KGC1/3
1/01/01919952.41(3) #10(3) #101.4737.3601.521.5739.92,0933,115170170 VFD2KGC1/03
2/02/01919952.41(3) #10(3) #101.5739.9601.521.6942.92,4703,676195195 VFD2KGC2/03
3/03/01919952.41(3) #8(3) #81.6742.4601.521.7945.52,9454,383225225 VFD2KGC3/03
4/04/01919952.41(3) #8(3) #81.8146.0601.521.9349.03,4785,176260260 VFD2KGC4/03
25025037371102.79(3) #8(3) #81.9349.0601.522.0552.14,0886,084290290 VFD2KGC250/3
35035037371102.79(3) #6(3) #62.1755.1601.522.2958.25,3597,975350350 VFD2KGC350/3
50050037371102.79(3) #6(3) #62.4161.2751.912.5665.07,12610,605430430 VFD2KGC500/3
60060061611253.17(3) #6(3) #62.6567.3751.912.8071.18,37212,459475475 VFD2KGC600/3
75075061611253.17(3) #4(3) #42.8572.4751.913.0076.210,14415,096535535 VFD2KGC750/3

Part numbers in this family (18)

By size:
Southwire #DescriptionConstructionStrandInsulation ThicknessGrounding ConductorsDiameter Over ArmorJacket ThicknessApprox. Diameter OverallApprox. Net WeightAmpacity (30°C ambient) 90°C Wet/Dry
VFD2KGC14/3VFD2KGC14/3 VFD JACKETED MC (ACWU90) RHW-2/CPE 2,000 Volt Copper 14 AWG 3C14 AWG 3C760(3) #140.63500.7337625
VFD2KGC12/3VFD2KGC12/3 VFD JACKETED MC (ACWU90) RHW-2/CPE 2,000 Volt Copper 12 AWG 3C12 AWG 3C760(3) #140.67500.7742630
VFD2KGC10/3VFD2KGC10/3 VFD JACKETED MC (ACWU90) RHW-2/CPE 2,000 Volt Copper 10 AWG 3C10 AWG 3C760(3) #140.73500.8349640
VFD2KGC8/3VFD2KGC8/3 VFD JACKETED MC (ACWU90) RHW-2/CPE 2,000 Volt Copper 8 AWG 3C8 AWG 3C780(3) #140.87500.9765855
VFD2KGC6/3VFD2KGC6/3 VFD JACKETED MC (ACWU90) RHW-2/CPE 2,000 Volt Copper 6 AWG 3C6 AWG 3C780(3) #120.95501.0583675
VFD2KGC4/3VFD2KGC4/3 VFD JACKETED MC (ACWU90) RHW-2/CPE 2,000 Volt Copper 4 AWG 3C4 AWG 3C780(3) #121.07501.171,06495
VFD2KGC3/3VFD2KGC3/3 VFD JACKETED MC (ACWU90) RHW-2/CPE 2,000 Volt Copper 3 AWG 3C3 AWG 3C780(3) #101.11501.211,234110
VFD2KGC2/3VFD2KGC2/3 VFD JACKETED MC (ACWU90) RHW-2/CPE 2,000 Volt Copper 2 AWG 3C2 AWG 3C780(3) #101.23501.331,416130
VFD2KGC1/3VFD2KGC1/3 VFD JACKETED MC (ACWU90) RHW-2/CPE 2,000 Volt Copper 1 AWG 3C1 AWG 3C1995(3) #101.37501.471,806150
VFD2KGC1/03VFD2KGC1/03 VFD JACKETED MC (ACWU90) RHW-2/CPE 2,000 Volt Copper 1/0 AWG1/0 AWG1995(3) #101.47601.572,093170
VFD2KGC2/03VFD2KGC2/03 VFD JACKETED MC (ACWU90) RHW-2/CPE 2,000 Volt Copper 2/0 AWG2/0 AWG1995(3) #101.57601.692,470195
VFD2KGC3/03VFD2KGC3/03 VFD JACKETED MC (ACWU90) RHW-2/CPE 2,000 Volt Copper 3/0 AWG3/0 AWG1995(3) #81.67601.792,945225
VFD2KGC4/03VFD2KGC4/03 VFD JACKETED MC (ACWU90) RHW-2/CPE 2,000 Volt Copper 4/0 AWG4/0 AWG1995(3) #81.81601.933,478260
VFD2KGC250/3VFD2KGC250/3 VFD JACKETED MC (ACWU90) RHW-2/CPE 2,000 Volt Copper 250 kcmil 3C250 kcmil 3C37110(3) #81.93602.054,088290
VFD2KGC350/3VFD2KGC350/3 VFD JACKETED MC (ACWU90) RHW-2/CPE 2,000 Volt Copper 350 kcmil 3C350 kcmil 3C37110(3) #62.17602.295,359350
VFD2KGC500/3VFD2KGC500/3 VFD JACKETED MC (ACWU90) RHW-2/CPE 2,000 Volt Copper 500 kcmil 3C500 kcmil 3C37110(3) #62.41752.567,126430
VFD2KGC600/3VFD2KGC600/3 VFD JACKETED MC (ACWU90) RHW-2/CPE 2,000 Volt Copper 600 kcmil 3C600 kcmil 3C61125(3) #62.65752.808,372475
VFD2KGC750/3VFD2KGC750/3 VFD JACKETED MC (ACWU90) RHW-2/CPE 2,000 Volt Copper 750 kcmil 3C750 kcmil 3C61125(3) #42.85753.0010,144535

Application & features

Application

For use in VFD applications. Suitable for use in hazardous locations: Class I - Div 2, Class II - Div 2, Class III - Div 1 and 2 *Patented for use with ServiceDrive ® connector and termination kit.

Specifications

Voltage Rating2 kV (2,000 V)2 kV
CertificationsMade in the USA, REACH, ROHS, Rockwell, ULMade in the USA, REACH, ROHS, Rockwell, UL

Standards & references

  • UL 1569, CSA C22.2 #51
  • ICEA S-95-658/NEMA WC-70
  • Flame Rated: IEEE 383 (70,000 BTU), IEEE 1202/CSA FT-4,
  • UL 1685, Two-hour Firewall
  • Temperature Rated at 90°C Wet/Dry, Cold Temperature Rated at -40°C
  • Sunlight Resistant
  • Direct Burial
  • Color Code: Black and Numbered
  • RoHS Compliant
  • NEMA BABA 70901-2-2024 WC-02-03, WC-02-04, WC-02-05
  • *U.S. Patent No. 7,309,835