Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)Conduit Size (in)(cm)
2 AWG2 AWG770.2820.720.5701.451253.18250.640.7461.89413615530240.405.914.992.56.35 60745799
1 AWG1 AWG19190.3220.820.6101.551253.18852.160.7862.00484720669303.456.215.752.56.35 60746599
1/0 AWG1/0 AWG19190.3610.920.6501.651253.18852.160.8262.10568845844382.836.616.762.56.35 60722699
2/0 AWG2/0 AWG19190.4051.030.6951.771253.18852.160.8712.216719991064482.626.917.532.56.35 60723499
3/0 AWG3/0 AWG19190.4561.160.7451.891253.181052.670.9552.4383012351342608.727.619.303.07.62 60724299
4/0 AWG4/0 AWG19190.5121.300.7851.991253.181052.670.9952.5397814551692767.487.920.073.07.62 60725999
250 KCMIL250 KCMIL37370.5581.420.8702.211403.561203.051.1122.82117917552000907.188.822.353.58.89 60726799
350 KCMIL350 KCMIL37370.6611.680.9652.451403.561203.051.2073.071531227828001270.069.624.383.58.89 60728399
500 KCMIL500 KCMIL37370.7892.001.0902.771403.561203.051.3223.362052305440001814.3710.526.674.010.16 60730999
750 KCMIL750 KCMIL61610.9682.461.3353.391553.941353.431.6114.093038452160002721.5512.832.514.511.43 60711999
1000 KCMIL1000 KCMIL61611.1172.841.4853.771553.941353.431.7614.473893579380003628.7414.035.565.012.70 60732599
2 AWG2 AWG0.1620.240.2040.300.0430.06145145--190190-- 60745799
1 AWG1 AWG0.1280.190.1620.240.0420.06170170--225225-- 60746599
1/0 AWG1/0 AWG0.1020.150.1280.190.0400.06195195--260260-- 60722699
2/0 AWG2/0 AWG0.0810.120.1020.150.0390.06220220--300300-- 60723499
3/0 AWG3/0 AWG0.0640.100.0810.120.0380.06250250--345345-- 60724299
4/0 AWG4/0 AWG0.0510.080.0650.100.0370.05290290--400400-- 60725999
250 KCMIL250 KCMIL0.0430.060.0560.080.0370.06320320--445445-- 60726799
350 KCMIL350 KCMIL0.0310.050.0410.060.0360.05385385--550550-- 60728399
500 KCMIL500 KCMIL0.0220.030.0300.040.0340.05470470--695695-- 60730999
750 KCMIL750 KCMIL0.0140.020.0230.030.0330.05585585--900900-- 60711999
1000 KCMIL1000 KCMIL0.0110.020.0190.030.0320.05670670--10751075-- 60732599
#2#2
500500601484601484

Part numbers in this family (11)

By size:
Southwire #DescriptionConstructionPackaging
607457992-7 CU 125 MILS NL-EPR/SIMpull PVC JKT 2400V N/S W/D2 AWG 1C 7SCUT TO LENGTH REEL
607465991-19 CU 125 MILS NL-EPR 2400V N/S WET/DRY PVC JACKET1 AWG 1C 19SCUT TO LENGTH REEL
607226991/0-19 CU 125 MILS NL-EPR 2400V N/S WET/DRY PVC JACKET1/0 AWG 1C 19SCUT TO LENGTH REEL
607234992/0-19 CU 125 MILS NL-EPR 2400V N/S WET/DRY PVC JACKET2/0 AWG 1C 19SCUT TO LENGTH REEL
607242993/0-19 CU 125 MILS NL-EPR 2400V N/S WET/DRY PVC JACKET3/0 AWG 1C 19SCUT TO LENGTH REEL
607259994/0-19 CU 125 MILS NL-EPR 2400V N/S WET/DRY PVC JACKET4/0 AWG 1C 19SCUT TO LENGTH REEL
60726799250-37 CU 140 MILS NL-EPR 2400V N/S WET/DRY PVC JACKET250 KCMIL 1C 37SCUT TO LENGTH REEL
60728399350-37 CU 140 MILS NL-EPR 2400V N/S WET/DRY PVC JACKET350 KCMIL 1C 37SCUT TO LENGTH REEL
60730999500-37 CU 140 MILS NL-EPR 2400V N/S WET/DRY PVC JACKET500 KCMIL 1C 37SCUT TO LENGTH REEL
60711999750-61 CU 155 MILS NL-EPR 2400V N/S WET/DRY PVC JACKET750 KCMIL 1C 61SCUT TO LENGTH REEL
607325991000-61 CU 155 MILS NL-EPR 2400V N/S WET/DRY PVC JACKET1000 KCMIL 1C 61SCUT TO LENGTH REEL

Application & features

Southwire’s 2.4KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation, 130°C for emergency overload, and 250°C for short circuit conditions. Cable can be installed in conduit without the aid of lubrication. Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-96-659 (NEMA WC 71) 2001-5000 V Nonshielded Cables
  • CT USE Sizes 1/0 AWG and Larger
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661