DistributorSouthwire

Southwire

CU Compressed 15kV NLEPR Insulation 133% IL AIA Black CPE Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46469

3 Conductor, 220 Mils No Lead Ethylene Propylene Rubber NL EPR, 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armor (AIA), Thermoplastic Chlorinated Polyethylene (CPE) Jacket. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (4) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Ground SizeInner Jacket Thickness (mils)(mm)Diameter Over Armor (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
2/0 AWG2/0 AWG19190.4051.030.8842.252205.590.9442.403x63x6601.522.5366.44751.912.6946.843878577131941448.7718.948.01 66866099
4/0 AWG4/0 AWG19190.5121.300.9902.512205.591.0502.673x13x1751.912.7677.03751.912.9257.435019746959782711.5720.552.07 66866699
500 KCMIL500 KCMIL37370.7892.001.2523.182205.591.3123.333x13x1751.913.3638.54902.293.5439.00923213739120005443.1024.862.99 66867099
750 KCMIL750 KCMIL61610.9682.461.4643.722205.591.5243.873x1/03x1/0852.163.8419.76902.294.02110.211258218724180008164.6628.071.12 66867399
2/0 AWG2/0 AWG0.0810.120.1020.150.0350.050.0420.060.472 + j0.4120.472 + j0.4120.102 + j0.0420.102 + j0.04229522952220220235235245245275275 66866099
4/0 AWG4/0 AWG0.0510.080.0650.100.0310.050.0410.060.432 + j0.3720.432 + j0.3720.066 + j0.0390.066 + j0.03932843284285285305305325325360360 66866699
500 KCMIL500 KCMIL0.0220.030.0300.040.0220.030.0340.050.378 + j0.2890.378 + j0.2890.030 + j0.0350.030 + j0.03541674167450450485485535535600600 66867099
750 KCMIL750 KCMIL0.0140.020.0230.030.0190.030.0340.050.355 + j0.2470.355 + j0.2470.024 + j0.0330.024 + j0.03347524752545545585585670670745745 66867399

Part numbers in this family (4)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
668660992/0-19 3/C CU 220 NL-EPR T/S PVC INNER JKT AIA BLACK CPE-TP JACKET 15KV133% UL2/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-/-/-CUT TO LENGTH REEL
668666994/0-19 3/C CU 220 NL-EPR T/S PVC INNER JKT AIA BLACK CPE-TP JACKET 15KV133% UL4/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-/-/-CUT TO LENGTH REEL
66867099500-37 3/C CU 220 NL-EPR T/S PVC INNER JKT AIA BLACK CPE-TP JACKET 15KV133% UL 0 FT500 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-/-/-CUT TO LENGTH REEL
66867399750-61 3/C CU 220 NL-EPR T/S PVC INNER JKT AIA BLACK CPE-TP JACKET 15KV133% UL750 KCMIL 3C 61SBLACK-/BLACK-/BLACK-/-/-/-CUT TO LENGTH REEL

Application & features

Southwire’s 15KV Teck type cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -40°C for cold bend and cold impact and marked with "LTGG" when CSA listed or dual UL/CSA listed. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs./ FT maximum sidewall pressure. The ground is sized to equal 50% of the phase conductor. Silicone free cable.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661