750-61 3/C CU 220 NL-EPR T/S PVC INNER JKT AIA BLACK CPE-TP JACKET 15KV133% UL
- Southwire #
- 66867399
3 Conductor, 220 Mils No Lead Ethylene Propylene Rubber NL EPR, 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armor (AIA), Thermoplastic Chlorinated Polyethylene (CPE) Jacket. Silicone Free
Part of the family: CU Compressed 15kV NLEPR Insulation 133% IL AIA Black CPE Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Application & features
Southwire’s 15KV Teck type cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -40°C for cold bend and cold impact and marked with "LTGG" when CSA listed or dual UL/CSA listed. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs./ FT maximum sidewall pressure. The ground is sized to equal 50% of the phase conductor. Silicone free cable.
Specifications
| Cond. Size | 750 KCMIL750 KCMIL |
|---|---|
| Cond. Strands | 6161 |
| Diameter Over Conductor | 0.968 inch2.46 cm |
| Diameter Over Insulation | 1.464 inch3.72 cm |
| Insulation Thickness | 220 mils5.59 mm |
| Diameter Over Shield | 1.524 inch3.87 cm |
| Ground Size | 3x1/03x1/0 |
| Inner Jacket Thickness | 85 mils2.16 mm |
| Diameter Over Armor | 3.841 inch9.76 cm |
| Jacket Thickness | 90 mils2.29 mm |
| Approx. OD | 4.021 inch10.21 cm |
| Approx. Weight | 12582 lbs/1000'18724 kgs/km |
| Max Pull Tension | 18000 lbs8164.66 kg |
| Min. Bend Radius | 28.0 inch71.12 cm |
Standards & references
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
- UL 1072 Medium-Voltage Power Cables
- UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
- ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
- AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
- Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661