DistributorSouthwire

Southwire

CU 600V PVC Insulation PVC Jacket Mini Split Type TC-ER-JP

Southwire #
SPEC10097

CU 600V PVC Insulation PVC Jacket Mini Split Type THHN/THWN Rated at 75ºC Wet 90ºC Dry

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (15) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsDiameter Over Conductor (in)(cm)ColorInsulation Thickness (mils)(mm)Ground SizeJacket Thickness (mils)(mm)Approx. OD (inches)(cm)Copper Weight (lbs/1000')(kgs/km)Approx. Weight (lbs/1000')(kgs/km)DC Resistance at 25C (ohms/1000')(ohms/km)AC Resistance at 75C (ohms/1000')(ohms/km)Min. Bend Radius (in)(cm)Allowable Ampacity Raceway 75CAllowable Ampacity Raceway 90C
16 AWG16 AWG442626BK, RD, WE, GNBK, RD, WE, GN200.51451.140.3430.873248721074.4876.685.4068.051.43.56--1818 58583501
14 AWG14 AWG44110.0640.16BK, RD, WE, GNBK, RD, WE, GN200.51451.140.3480.885074891322.6313.923.1704.721.43.5616162020 59540702
14 AWG14 AWG33770.0640.16BK, RD, GNBK, RD, GN200.511 x 141 x 14451.140.3370.863857751122.6313.923.1704.721.33.3020202525 13854301
14 AWG14 AWG44770.0700.18BK, RD, WE, GNBK, RD, WE, GN200.51451.140.3510.895176931382.6313.923.1704.721.43.5616162020 58225703
14 AWG14 AWG77770.0700.18BK, RD, BE, OE, YW, BN, RD/BKBK, RD, BE, OE, YW, BN, RD/BK200.51451.140.4291.09901341512252.6313.923.1704.721.74.3214141717 40863301

Part numbers in this family (15)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
16 AWG · 3 conductors (2)
5858350516-26 3/C CU TFFN/PVC BLACK/RED/WHITE 1x16 GG TYPE TC-ER-JP 600V BLACK 50 FT16 AWG 3C 26SBLACK/RED/WHITE50 FT COIL
5858350116-26 3/C CU TFFN/PVC BLACK/RED/WHITE 1x16 GG TYPE TC-ER-JP 600V BLACK 250 FT16 AWG 3C 26SBLACK/RED/WHITE250 FT REEL
14 AWG · 3 conductors (5)
1385430214-7 CU 3/C THHN/PVC MINISPLIT TYPE TC 600V BLACK 50 FT14 AWG 3C 7 STRBLACK/RED/GREEN50 FT COIL
1385430114-7 CU 3/C THHN/PVC MINISPLIT TYPE TC 600V BLACK 250 FT14 AWG 3C 7 STRBLACK/RED/GREEN250 FT SPOOL
5954070214 SOL CU 4/C THHN/PVC MINISPLIT TYPE TC 600V BLACK 50 FT14 AWG 3C SOLBLACK/RED/WHITE50 FT COIL
5954070314 SOL CU 4/C THHN/PVC MINISPLIT TYPE TC 600V BLACK 250 FT14 AWG 3C SOLBLACK/RED/WHITE250 FT SPOOL
5954070514 SOL CU 4/C THHN/PVC MINISPLIT TYPE TC 600V BLACK 2500 FT14 AWG 3C SOLBLACK/RED/WHITE2500 FT REEL
14 AWG · 4 conductors (4)
5822579914-7 CU 4/C THHN/PVC MINISPLIT TYPE TC 600V BLACK14 AWG 4C 7 STRBLACK/RED/WHITE/GREENCUT TO LENGTH REEL
5822570514-7 CU 4/C THHN/PVC MINISPLIT TYPE TC 600V BLACK 50 FT14 AWG 4C 7 STRBLACK/RED/WHITE/GREEN50 FT COIL
5822570314-7 CU 4/C THHN/PVC MINISPLIT TYPE TC 600V BLACK 250 FT14 AWG 4C 7 STRBLACK/RED/WHITE/GREEN250 FT SPOOL
5822570714-7 CU 4/C THHN/PVC MINISPLIT TYPE TC 600V BLACK 1000 FT14 AWG 4C 7 STRBLACK/RED/WHITE/GREEN1000 FT REEL
14 AWG · 7 conductors (4)
4086339914-7 7/C CU THHN/PVC BLACK/RED/BLUE/ORANGE/YELLOW/BROWN/RED-BLACK TYPE TC-ER-JP 600V BLACK14 AWG 7C 7SBLACK/RED/BLUE/ORANGE/YELLOW/BROWN/RED-BLACK STRIPECUT TO LENGTH REEL
4086330514-7 7/C CU THHN/PVC BLACK/RED/BLUE/ORANGE/YELLOW/BROWN/RED-BLACK TYPE TC-ER-JP 600V BLACK 50 FT14 AWG 7C 7SBLACK/RED/BLUE/ORANGE/YELLOW/BROWN/RED-BLACK STRIPE50 FT COIL
4086330114-7 7/C CU THHN/PVC BLACK/RED/BLUE/ORANGE/YELLOW/BROWN/RED-BLACK TYPE TC-ER-JP 600V BLACK 250 FT14 AWG 7C 7SBLACK/RED/BLUE/ORANGE/YELLOW/BROWN/RED-BLACK STRIPE250 FT SPOOL
4086330214-7 7/C CU THHN/PVC BLACK/RED/BLUE/ORANGE/YELLOW/BROWN/RED-BLACK TYPE TC-ER-JP 600V BLACK 1000 FT14 AWG 7C 7SBLACK/RED/BLUE/ORANGE/YELLOW/BROWN/RED-BLACK STRIPE1000 FT REEL

Application & features

Southwire’s 600 Volt Type TC-ER-JP control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 75°C in wet locations and 90°C in dry locations, 105°C for emergency overload, and 150°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. Sunlight Resistant - For Direct Burial - Silicone Free - VW-1 Rated.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 83 Thermoplastic Insulated Wire and Cables (sizes 14 AWG to 1000 kcmil)
  • UL 1277 Electrical Power and Control Tray Cables
  • RoHS-3 Complies with European Directive 2015/863