DistributorSouthwire

Southwire

AL Compact 15kV NLEPR Insulation 133% IL AIA Red PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46459

Type MV-105 Three Conductor Aluminum, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Aluminum Interlocked Armor (AIA), Polyvinyl Chloride (PVC) Jacket. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (6) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Ground SizeDiameter Over Armor (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
1/0 AWG1/0 AWG10100.3360.850.8142.072205.590.8742.221x61x62.2595.74751.912.4096.12233534751900861.8216.842.67 57768899
2/0 AWG2/0 AWG12120.3760.960.8542.172205.590.9142.321x41x42.3455.96802.032.5116.382620389923951086.3517.544.45 59778199
4/0 AWG4/0 AWG18180.4741.200.9532.422205.591.0132.571x41x42.5596.50802.032.7256.923089459738081727.2819.048.26 57773899
250 KCMIL250 KCMIL22220.5201.321.0062.562205.591.0662.711x3/01x3/02.6746.79802.032.8407.213734555745002041.1619.850.29 59756199
500 KCMIL500 KCMIL34340.7351.871.2443.162205.591.3043.311x11x13.1888.10902.293.3768.585019746990004082.3323.659.94 57768799
750 KCMIL750 KCMIL58580.9082.311.4163.602205.591.4763.751x11x13.5609.04902.293.7479.5261279118135006123.4926.266.55 64704299
1/0 AWG1/0 AWG0.1680.250.2110.310.0460.070.0440.070.379 + j0.2610.379 + j0.2610.047 + j0.0420.047 + j0.04227382738150150165165170170185185 57768899
2/0 AWG2/0 AWG0.1330.200.1670.250.0420.060.0430.060.379 + j0.3020.379 + j0.3020.031 + j0.0380.031 + j0.03828622862170170185185190190215215 59778199
4/0 AWG4/0 AWG0.0840.130.1050.160.0360.050.0400.060.381 + j0.2780.381 + j0.2780.042 + j0.0420.042 + j0.04231663166220220240240255255285285 57773899
250 KCMIL250 KCMIL0.0710.110.0900.130.0340.050.0390.060.381 + j0.2780.381 + j0.2780.042 + j0.0420.042 + j0.04233333333245245265265280280315315 59756199
500 KCMIL500 KCMIL0.0350.050.0460.070.0260.040.0350.050.382 + j0.2810.382 + j0.2810.040 + j0.0370.040 + j0.03739993999355355385385425425475475 57768799
750 KCMIL750 KCMIL0.0240.040.0330.050.0220.030.0330.050.382 + j0.3090.382 + j0.3090.031 + j0.0350.031 + j0.03545664566440440475475540540600600 64704299

Part numbers in this family (6)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
577688991/0-10 3/C 3E AL 220 NL-EPR T/S 1X6 CU GW AIA RED PVC JACKET 15KV 133%UL1/0 AWG 3C 10 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
597781992/0-12 3/C 3E AL 220 NL-EPR T/S 1X4 CU GW AIA RED PVC JACKET 15KV 133%UL2/0 AWG 3C 12 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
577738994/0-18 3/C 3E AL 220 NL-EPR T/S 1X4 CU GW AIA RED PVC JACKET 15KV 133%UL4/0 AWG 3C 18SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
59756199250-22 3/C 3E AL 220 NL-EPR T/S 1X3/0 CU GW AIA RED PVC JACKET 15KV 133% UL250 KCMIL 3C 22 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
57768799500-34 3/C 3E AL 220 NL-EPR T/S 1X1 CU GW AIA RED PVC JACKET 15KV 133%UL500 KCMIL 3C 34SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
64704299750-53 3/C 3E AL 220 NL-EPR T/S 1X1 CU GW AIA RED PVC JACKET 15KV 133%UL750 KCMIL 3C 53SBLACK/BLACK/BLACKCUT TO LENGTH REEL

Application & features

Southwire’s 15KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -40°C for cold bend and cold impact and marked with "LTGG" when CSA listed or dual UL/CSA listed. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
  • ASTM B836 Compact Rounded Stranded Aluminum Conductors
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661