Cable de Potencia XLPE Corrugado 345 kV
- Núm. Southwire
- HVUD22
Cable SW de pared estándar con conductor de cobre XLPE y cubierta corrugada, disponible hasta 6,000 kcmil.
Precio bajo cotización — el cobre cambia a diario (COMEX), por eso cotizamos con el precio vigente.
Tamaños y construcciones disponibles
| Tamaño (kcmil¹)(mm^2) | Diámetro del Conductor (inches)(mm) | Espesor del Aislamiento (inch)(cm) | Diámetro Sobre Aislamiento (inch)(cm) | Diámetro de Cubierta General (inch)(cm) | Radio de Curvatura Mín. (inch)(inch) | Capacitancia | Corriente de Carga (A/kft) | Peso del Cable² (lbs/ft) | Forro de 30 mil Cortocircuito @ 0.5s (kA) | Peso del Cable² (lbs/ft) | Forro de 30 mil Cortocircuito @ 0.5s (kA) | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 125031.75 | 1.193.02 | 12603200.40 | 3.889.86 | 4.9112.47 | 89/5989/59 | 38.3738.37 | 3.373.37 | 11.7311.73 | 56.6056.60 | 00 | 00 | |
| 150038.10 | 1.323.35 | 11812999.74 | 3.859.78 | 5.0012.70 | 90/6090/60 | 42.7542.75 | 3.723.72 | 12.4112.41 | 57.7057.70 | 00 | 00 | |
| 175044.45 | 1.433.63 | 11422900.68 | 3.889.86 | 5.0312.78 | 91/6191/61 | 45.7345.73 | 3.983.98 | 13.1713.17 | 58.0058.00 | 00 | 00 | |
| 200050.80 | 1.503.81 | 11422900.68 | 3.9510.03 | 5.1213.00 | 93/6293/62 | 47.3247.32 | 4.124.12 | 14.1714.17 | 59.1059.10 | 00 | 00 | |
| 250063.50 | 1.734.39 | 10632700.02 | 4.0510.29 | 5.2313.28 | 95/6395/63 | 54.5854.58 | 4.754.75 | 15.7815.78 | 60.3060.30 | 00 | 00 | |
| 300076.20 | 1.894.80 | 10632700.02 | 4.2810.87 | 5.5013.97 | 99/6699/66 | 59.1359.13 | 5.155.15 | 17.8917.89 | 63.4063.40 | 00 | 00 | |
| 350088.90 | 2.075.26 | 10632700.02 | 4.3811.13 | 5.6214.27 | 102/68102/68 | 61.2461.24 | 5.335.33 | 19.7019.70 | 64.9064.90 | 00 | 00 | |
| 4000101.60 | 2.175.51 | 10632700.02 | 4.4811.38 | 5.7414.58 | 104/69104/69 | 63.1963.19 | 5.505.50 | 21.4821.48 | 66.2066.20 | 00 | 00 | |
| 5000127.00 | 2.486.30 | 10632700.02 | 4.7912.17 | 6.1015.49 | 110/74110/74 | 69.3269.32 | 6.046.04 | 26.0426.04 | 70.5070.50 | 00 | 00 | |
| 6000152.40 | 2.676.78 | 10632700.02 | 4.9912.67 | 6.3316.08 | 114/76114/76 | 73.1373.13 | 6.376.37 | 28.9328.93 | 73.2073.20 | 00 | 00 | |
| 125031.75 | 900900 | 624624 | 760760 | 527527 | 720720 | 499499 | 610610 | 423423 | ||||
| 150038.10 | 990990 | 686686 | 820820 | 568568 | 790790 | 547547 | 660660 | 457457 | ||||
| 175044.45 | 10601060 | 734734 | 880880 | 610610 | 860860 | 596596 | 710710 | 492492 | ||||
| 200050.80 | 11101110 | 769769 | 920920 | 637637 | 910910 | 630630 | 760760 | 527527 | ||||
| 250063.50 | 13101310 | 908908 | 10701070 | 741741 | 10601060 | 734734 | 870870 | 603603 | ||||
| 300076.20 | 14301430 | 991991 | 11601160 | 804804 | 11701170 | 811811 | 950950 | 658658 | ||||
| 350088.90 | 15201520 | 10531053 | 12201220 | 845845 | 12601260 | 873873 | 10201020 | 707707 | ||||
| 4000101.60 | 16001600 | 11091109 | 12901290 | 894894 | 13401340 | 928928 | 10801080 | 748748 | ||||
| 5000127.00 | 17401740 | 12061206 | 13801380 | 956956 | 15101510 | 10461046 | 12001200 | 831831 | ||||
| 6000152.40 | 18201820 | 12611261 | 14401440 | 998998 | 16201620 | 11221122 | 12901290 | 894894 |
Aplicación y características
Se utiliza predominantemente para transmisión subterránea en sistemas de tubo conduit, adecuado para uso en lugares húmedos o secos, enterramiento directo, ductos subterráneos y donde esté expuesto a la luz solar. Debe utilizarse a 345,000 voltios o menos y a temperaturas del conductor que no excedan 90°C para operación normal.
Normas y referencias
- Max Voltage Rating: 362 kV
- BIL Rating: 1300 kV
- Nominal Conductor: 90 °C
- Max. Emergency Conductor: 105 °C
- Short Circuit Conductor: 250 °C
- Minimum Installation: -10 °C
- Design Standards: AEIC, ICEA, IEC
- Factory Test Voltages: 440 kV / 60 min.
- XLPE Loss Factor: 0.0005
- Relative Permittivity: 2.3