Computer Blue Liquidtight Flexible Metal Conduit. Easy to Identify Blue Jacket for Computer Applications. UL/CSA Listed. Oil-Resistant. Sunlight-Resistant. Temperature Rated -55°C to 80°C.

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (12) ↓

Available sizes & constructions

Cond. SizeDia. Over Inner Jacket (in)(cm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Min. Bend Radius (in)(cm)
1/2 Inch1/2 Inch0.6221.580.8202.0830456.516.51 55093402
3/4 Inch3/4 Inch0.8202.081.0302.6238578.521.59 55093502
1 Inch1 Inch1.0412.641.2903.28608913.033.02 55093603
1-1/4 Inch1-1/4 Inch1.3803.511.6304.148011916.040.64 55280901
1-1/2 Inch1-1/2 Inch1.5754.001.8654.7411316818.045.72 55281103
2 Inch2 Inch2.0205.132.3405.9414922222.356.64 55281203
InchInchInchInchInchInchLb/100ftLb/100ftInchInch
3/83/80.484/0.5040.484/0.5040.690/0.7100.690/0.71023233*3*
1/21/20.622/0.6420.622/0.6420.820/0.8400.820/0.840303044
3/43/40.820/0.8400.820/0.8401.030/1.0501.030/1.050383855
111.041/1.0661.041/1.0661.290/1.3151.290/1.315606088
1-1/41-1/41.380/1.4101.380/1.4101.630/1.6601.630/1.66080801010
1-1/21-1/21.575/1.6001.575/1.6001.865/1.9001.865/1.9001131131212
222.020/2.0452.020/2.0452.340/2.3752.340/2.3751491491616
2-1/22-1/22.480/2.5052.480/2.5052.840/2.8752.840/2.8751881882020
333.070/3.1003.070/3.1003.460/3.5003.460/3.5002352352424
3-1/23-1/23.500/3.5403.500/3.5403.960/4.0003.960/4.0003013012828
444.000/4.0404.000/4.0404.460/4.5004.460/4.5003103103232
3/83/855290701552907015529070255290702
1/21/2
3/43/4
11
1-1/41-1/45528090355280903
1-1/21-1/25528110155281101
225528120155281201
2-1/22-1/255281303552813035528130155281301
335516990355169903
3-1/23-1/25528540355285403
445528550355285503

Part numbers in this family (12)

By size:
Southwire #DescriptionSizeLengthColor
1/2" (3)
550934021/2" TITAN METAL-FLEX CONDUIT TYPE CB BLUE 1000 FT1/21000BLUE
550934031/2" TITAN METAL-FLEX CONDUIT TYPE CB BLUE 100 FT1/2100BLUE
550934041/2" TITAN METAL-FLEX CONDUIT TYPE CB BLUE 500 FT1/2500BLUE
3/4" (3)
550935023/4" TITAN METAL-FLEX CONDUIT TYPE CB BLUE 1000 FT3/41000BLUE
550935043/4" TITAN METAL-FLEX CONDUIT TYPE CB BLUE 500 FT3/4500BLUE
550935053/4" TITAN METAL-FLEX CONDUIT TYPE CB BLUE 100 FT3/4100BLUE
1" (2)
550936031" TITAN METAL-FLEX CONDUIT TYPE CB BLUE 100 FT1100BLUE
550936041" TITAN METAL-FLEX CONDUIT TYPE CB BLUE 400 FT1400BLUE
1-1/4" (2)
552809011-1/4" TITAN METAL-FLEX CONDUIT TYPE CB BLUE 250 FT1-1/4250BLUE
552809991-1/4" TITAN METAL-FLEX CONDUIT TYPE CB BLUE1-1/4Cut to LengthBLUE
1-1/2" (1)
552811031-1/2" TITAN METAL-FLEX CONDUIT TYPE CB BLUE 50 FT1-1/250BLUE
2" (1)
552812032" TITAN METAL-FLEX CONDUIT TYPE CB BLUE 50 FT250BLUE

Application & features

Titan2™ Type CB Liquidtight Flexible Metal Conduit is suitable for the following installations:

  • Under raised floors in data processing areas per NEC 645.5(D) & 645.5(D)(2)
  • For the installation and protection of electrical conductors in circuits of 600 Volts nominal, or less.
  • Where the conditions of installation, operation, or maintenance require flexibility or protection from liquids, vapors, solids, or weather
  • Used in industrial and commercial applications for conveyors, blowers, cranes, air conditioners, machine tooling and lubrication equipment
  • Applications requiring movement, crossover connections, or tight bends
  • Exposed or concealed locations
  • For flexible connections to swimming pool, spa, and hot tub motors per NEC 680.21(A)(3) & 680.42(A)(1)
  • Electric signs and outline lighting supply and secondary-circuit per NEC 600.31 (1000 Volts or less) & NEC 600.32 (over 1000 Volts).
  • Permitted for equipment grounding in sizes 3/8" through 1-1/4" in lengths not exceeding 6 feet per NEC 250.118(6)
  • Floating building feeders and services per NEC 553.7(B)
  • Boatyards & Marinas in accordance with NEC 555.13
  • Cranes & Hoists in accordance with NEC 610.11(C)
  • For Elevator, Dumbwaiters, Escalators, Moving Walks, Wheel Chair Lifts & Stairway Chair Lifts in accordance with NEC 620.21 (where expressly permitted)
  • In Hazardous Locations - where necessary for flexible connections within hazardous locations in accordance with the following:

  • Class I, Div. 2 - NEC 501.10(B)(2) & 501.30(B)
  • Class II, Div. 1 - NEC 502.10(A)(2) & 502.30(B)
  • Class II, Div. 2 - NEC 502.10(B)(2)
  • Class III, Div. 1 - NEC 503.10(A)(2) & 503.30(B)
  • Class III, Div. 2 - NEC 503.10(A)(2)

  • Titan2™ Type CB Liquidtight Flexible Metal Conduit meets or exceeds the following requirements:
  • NFPA 70 (National Electrical Code), Article 350 - Liquidtight Flexible Metal Conduit
  • UL Listed to Underwriters Laboratories Standard ANSI / UL-360 for Liquidtight Flexible Steel Conduit
  • CSA Listed to CSA 22.2 No.56 for use per the Canadian Electrical Code C22.1 Section 12-1300
  • REACH/RoHS-2 (Chemical Limit) Compliant

  • Features
  • Blue color easily identifies raceways for uninterrupted computer power circuits
  • A protective thermoplastic outer jacket which seals out water, liquids, abrasives, alcohol, coolants, corrosive fumes and gases, dirt, grease, mineral acids, non-concentrated fixed alkalines, petroleum oils, salt air and spray, and weather
  • Smooth metal interior for easy wiring pulling
  • UV sunlight resistant jacket
  • Rated for temperature range of -55°C to 80°C , 60°C Oil (-22°F to +176°F, 140°F Oil)
  • Accepts standard metallic liquid-tight fittings
  • Rated for direct burial applications
  • Standards & references

    • UL 360 Liquidtight Flexible Steel Conduit
    • CSA 22.2 No. 56 Flexible metal conduit and liquid-tight flexible metal conduit
    • NFPA 70 (National Electrical Code), Article 350 - Liquidtight Flexible Metal Conduit