TCU 600/1000V EPR Insulation XHHW-2 Thermoplastic CPE-TP Jacket. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free

Southwire #
SPEC45106

Type TC-ER Control Cable, 600/100 Volt Tinned Copper Conductors, Ethylene Propylene Rubber (EPR) Insulation XHHW-2, Thermoplastic Chlorinated Polyethylene (CPE-TP) Jacket with 1 Tinned Copper Ground, Control Cable Conductor Identification Method 1 Table 2, VW-1 Rated

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (3) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsInsulation Thickness (mils)(mm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Copper Weight (lbs/1000')(kgs/km)Approx. Weight (lbs/1000')(kgs/km)DC Resistance at 25C (ohms/1000')(ohms/km)AC Resistance at 75C (ohms/1000')(ohms/km)Min. Bend Radius (in)(cm)Allowable Ampacity Raceway 75CAllowable Ampacity Raceway 90C
14 AWG14 AWG3377300.76451.140.4411.1250741161732.6313.923.1704.721.84.5720202525 59194699
12 AWG12 AWG3377300.76451.140.4501.14811211432131.6622.472.0022.981.84.5725253030 59196199
10 AWG10 AWG3377300.76451.140.5111.301291922043041.0401.551.2531.862.05.0835354040 59197599

Part numbers in this family (3)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
5919469914-7 3/C TINNED CU XHHW/CPE BLACK/RED/BLUE/ 1x14 GW TYPE TC-ER 1000V BLACK14 AWG 3C 7 STRBLACK/RED/BLUECUT TO LENGTH REEL
5919619912-7 3/C TINNED CU XHHW/CPE BLACK/RED/BLUE 1x12 GW TYPE TC-ER 1000V BLACK12 AWG 3C 7SBLACK/RED/BLUECUT TO LENGTH REEL
5919759910-7 3/C TINNED CU XHHW/CPE BLACK/RED/BLUE 1x10 GW TYPE TC-ER 1000V BLACK10 AWG 3C 7 STRBLACK/RED/BLUECUT TO LENGTH REEL

Application & features

Southwire’s 600/1000 Volt Type TC-ER control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.

Standards & references

  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 44 VW-1 Vertical flame test on individual conductors
  • UL 1277 Electrical Power and Control Tray Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2
  • ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test