DistributorSouthwire

Southwire

TCU 2000V NLEPR Insulation Thermoset LSZH-TS Jacket. RHH/RHW-2

Southwire #
SPEC45503

Power Cable 2000 Volt Single Conductor Copper or Tinned Copper, Ethylene Propylene Rubber (EPR) insulation RHH/RHW-2 Thermoset SOLONON® (LSZH-TS) Jacket

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (8) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Copper Weight (lbs/1000')(kgs/km)Approx. Weight (lbs/1000')(kgs/km)
1/0 AWG1/0 AWG1119190.3620.92651.65451.140.5981.52326485428637 67218599
250 KCMIL250 KCMIL112592590.6101.551052.67651.650.9722.47811120710691591 66427899
500 KCMIL500 KCMIL112592590.8902.261052.67651.651.2523.181579235019242863 64941799
750 KCMIL750 KCMIL1161610.9682.46902.29651.651.2973.292316344726503944 56879899
750 KCMIL750 KCMIL111271270.9682.46902.29651.651.3003.302315344526523947 64388199
1000 KCMIL1000 KCMIL111271271.1182.84902.29651.651.4503.683088459534685161 65313299
2000 KCMIL2000 KCMIL111271271.5834.021152.92952.412.0315.1661759189690310273 55138001
1/0 AWG1/0 AWG114.711.94845383.290.1020.150.1220.180.0440.07150150170170 67218599
250 KCMIL250 KCMIL117.819.812000907.180.0430.060.0530.080.0410.06255255290290 66427899
500 KCMIL500 KCMIL1110.025.4040001814.370.0220.030.0290.040.0390.06380380430430 64941799
750 KCMIL750 KCMIL1110.225.9160002721.550.0140.020.0220.030.0380.06475475535535 56879899
750 KCMIL750 KCMIL1110.426.4260002721.550.0140.020.0220.030.0380.06475475535535 64388199
1000 KCMIL1000 KCMIL1111.629.4680003628.740.0110.020.0180.030.0370.06545545615615 65313299
2000 KCMIL2000 KCMIL1116.040.64100004535.920.0050.010.0160.020.0340.05665665750750 55138001

Part numbers in this family (8)

By size:
Southwire #DescriptionConstructionPackaging
1/0 AWG (1)
672185991/0-19 TINNED CU 65 NL-EPR/45 LSZH 2KV RHH/RHW-2 BLACK1/0 AWG 1C 19SCUT TO LENGTH REEL
250 kcmil (1)
66427899250-259 TINNED CU 105 NL-EPR/65 LSZH 2KV RHH/RHW-2 BLACK250 KCMIL 1C 259SCUT TO LENGTH REEL
500 kcmil (1)
64941799500-259 TINNED CU 105 NL-EPR/65 LSZH 2KV RHH/RHW-2 BLACK500 KCMIL 1C 259SCUT TO LENGTH REEL
750 kcmil (2)
64388199750-127 TINNED CU 90 NL-EPR/65 LSZH 2KV RHH/RHW-2 BLACK750 KCMIL 1C 127SCUT TO LENGTH REEL
56879899750-61 TINNED CU 90 NL-EPR/65 LSZH 2KV RHH/RHW-2 BLACK750 KCMIL 1C 61SCUT TO LENGTH REEL
1000 kcmil (1)
653132991000-127 TINNED CU 90 NL-EPR/65 LSZH 2KV RHH/RHW-2 BLACK1000 KCMIL 1C 127SCUT TO LENGTH REEL
2000 kcmil (2)
551380992000-127 CU 115 NL-EPR/95 LSZH 2KV RHH/RHW-2 BLACK2000 KCMIL 1C 127SCUT TO LENGTH REEL
551380012000-127 CU 115 NL-EPR/95 LSZH 2KV RHH/RHW-2 BLACK 500 FT2000 KCMIL 1C 127S500 FT REEL

Application & features

Southwire’s 2000 Volt power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502.

Standards & references

  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
  • ASTM B173 Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (250kcmil & Larger)
  • NFPA 502 Standard for Road Tunnels, Bridges, and Other Limited Access Highways (non-emergency circuits only)
  • AREMA 10.3.13 Recommended Design Criteria for Low-Smoke Halogen Free (LSHF) Polymeric Cable Jackets