DistributorSouthwire

Southwire

Southwire® Machine Flex® TCU 600/1000V XLPE Insulation Shielded Signal Pair TPE Jacket. RHH/RHW-2 Flexible Variable Frequency Drive (VFD). Silicone-Free

Southwire #
SPEC45441

Southwire® Machine Flex® Type TC-ER Variable Frequency Drive Cable, 600 Volts or 1000 Volts , Tinned Copper Conductors, Cross Linked Insulation Type RHH/RHW-2 With Shielded Pair, Thermoplastic Elastomer Jacket, Rated 90°C Dry or Wet, -40°C Cold Impact, Identification Method 4. 1000 Volts Flexible Motor Supply. CSA CIC/TC FT4 Flame. Sunlight Resistant, Direct Burial, Silicone Free.

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (6) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Drain WireDiameter Over Shield (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Copper Weight (lbs/1000')(kgs/km)Approx. Weight (lbs/1000')(kgs/km)
16 AWG16 AWG3326260.0590.15451.141x161x160.4801.22621.570.6041.5392137199296 64624199
14 AWG14 AWG3341410.0730.19451.141x141x140.5651.44621.570.6891.75128190242360 64624299
12 AWG12 AWG3365650.0940.24451.141x121x120.5951.51621.570.7191.83169251308458 64624399
10 AWG10 AWG331051050.1170.30451.141x101x100.6491.65621.570.7731.96233347370551 64624499
8 AWG8 AWG331681680.1530.39601.524x144x140.8702.21822.081.0342.63367546654973 67715699
6 AWG6 AWG332662660.1980.50601.524x124x120.9352.37822.081.0992.795197728291234 67715899
16 AWG16 AWG337.218.296127.674.4876.685.4068.050.0650.100.0330.05--1818 64624199
14 AWG14 AWG338.321.089844.452.8144.193.3915.050.0570.080.0580.0920202525 64624299
12 AWG12 AWG338.621.8415670.761.7742.642.1373.180.0470.070.0540.0825253030 64624399
10 AWG10 AWG339.323.62249112.941.1111.651.3391.990.0400.060.0500.0735354040 64624499
8 AWG8 AWG3312.431.50396179.620.7151.060.8611.280.0400.060.0520.0850505555 67715699
6 AWG6 AWG3313.233.53629285.310.4500.670.5410.810.0330.050.0510.0865657575 67715899
16161818
16161818
16161818
14141414
14141414

Part numbers in this family (6)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
6462419916/4 & 16/1PR FLEX VFD/TC-ER WTTC BLACK16 AWG 2C 26 STR1-ONE/2-TWO/3-THREECUT TO LENGTH REEL
6462429914/4 & 16/1PR FLEX VFD/TC-ER WTTC BLACK14 AWG 6C 41S1-ONE/2-TWO/3-THREECUT TO LENGTH REEL
6462439912/4 & 16/1PR FLEX VFD/TC-ER WTTC BLACK12 AWG 6C 65S1-ONE/2-TWO/3-THREECUT TO LENGTH REEL
6462449910/4 & 16/1PR FLEX VFD/TC-ER WTTC BLACK10 AWG 6C 105S1-ONE/2-TWO/3-THREECUT TO LENGTH REEL
677156998/4 & 14/1PR FLEX VFD/TC-ER WTTC BLACK8 AWG 8C 168SCUT TO LENGTH REEL
677158996/4 & 14/1PR FLEX VFD/TC-ER WTTC BLACK6 AWG 8C 266SCUT TO LENGTH REEL

Application & features

Applications and Features: Power supply cable for VFDs and motors, suitable for cable tray, conduit, raceways, (TC-ER) and machine tool wiring conforming to NFPA 79. Suitable for free air and direct burial. Its flexible design is ideal for use on operation processes in accordance with NEC® Articles 336, 501 and 502 including, but not limited to: fans, pumps, conveyors, compressors, elevators and lifts, extruders, crushers and presses, assembly lines, food and beverage, wind energy and data centers. Cable is rated for -40C Cold Bend and Impact. Multiple approvals for multiple applications. The additional shielded pair can be used for signal, temperature sensors or brake.

Standards & references

  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
  • ASTM B174 Standard Specification for Bunch-Stranded Copper
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 758 Standard for Appliance Wiring Material Style 20886
  • UL 1277 Type TC-ER Standard Power and Control Cables (1000V 14AWG and Larger)
  • UL 2277 Flexible Motor Supply & Type WTTC
  • CSA C22.2 No. 210 Appliance wiring material products I/II A/B (Sizes 16 - 8AWG)
  • CSA C22.2 No.230 Tray Cables - Rated TC
  • CSA C22.2 No. 239 Control and instrumentation cables
  • ICEA S-58-679 Control Cable Conductor Identification Method 4
  • Exceeds Ecolab PM-40-1 Material Resistance Test With 30-day Exposure, UL Verified V747862
  • CE/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011/65/EU) Directive
  • NFPA 79 Electrical Standard for Industrial Machinery
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661