Southwire® Machine Flex® TCU 1000V XLPE Insulation Three Symmetrical Grounds Shielded TPE Jacket. XHHW-2 Flexible Variable Frequency Drive (VFD). Silicone-Free
- Southwire #
- SPEC45443
Reduced Diameter Type TC-ER Variable Frequency Drive Cable 600 Volt Tinned Copper Conductors, Crosslinked Insulation Type XHHW-2. Thermoplastic Elastomer Jacket. Rated 90C Dry or Wet, -40C Cold Impact, Identification Method 4, 1000 Volt Flexible Motor Supply. CSA CIC/TC FT4 Flame. Silicone-Free
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (2) ↓Available sizes & constructions
| Cond. Size | Conductor Number | Cond. Strands | Diameter Over Conductor (in)(cm) | Insulation Thickness (mils)(mm) | Ground Size | Jacket Thickness (mils)(mm) | Approx. OD (inches)(cm) | Copper Weight (lbs/1000')(kgs/km) | Approx. Weight (lbs/1000')(kgs/km) | |
|---|---|---|---|---|---|---|---|---|---|---|
| 12 AWG12 AWG | 33 | 6565 | 0.0940.24 | 300.76 | 3x163x16 | 451.14 | 0.4701.19 | 112167 | 173257 | 67095701 |
| 12 AWG12 AWG | 33 | 5.614.22 | 15670.76 | 1.7742.64 | 2.1373.18 | 0.0540.08 | 2525 | 3030 | 67095701 | |
| (AWG/Kcmil)(AWG/Kcmil) | 230V(HP)230V(HP) | 460V(HP)460V(HP) | 475V(HP)475V(HP) | (mils)(mils) | ||||||
| 1616 | -- | 55 | 55 | 0.5350.535 | ||||||
| 1414 | 55 | 7.57.5 | 1010 | 0.5670.567 | ||||||
| 1212 | 55 | 1010 | 1010 | 0.6080.608 | ||||||
| 1010 | 7.57.5 | 1515 | 2020 | 0.6710.671 | ||||||
| 88 | 7.57.5 | 3030 | 3030 | 0.8370.837 | ||||||
| 66 | 1515 | 4040 | 5050 | 0.8980.898 | ||||||
| 44 | 2020 | 5050 | 6060 | 0.9950.995 | ||||||
| 22 | 3030 | 6060 | 7575 | 1.1351.135 | ||||||
| 11 | 4040 | 7575 | 100100 | 1.221.22 |
Part numbers in this family (2)
| Southwire # | Description | Construction | Conductor Color | Packaging | |
|---|---|---|---|---|---|
| 12 AWG (2) | |||||
| 67095799 | 12-65 3/C TINNED CU XHHW-2 3x16 GW T/S TPE JKT TC-ER 600V VFD | 12 AWG 3C 65 STR | 1-ONE/2-TWO/3-THREE | CUT TO LENGTH REEL | |
| 67095701 | 12-65 3/C TINNED CU XHHW-2 3x16 GW T/S TPE JKT TC-ER 600V VFD 1000 FT | 12 AWG 3C 65 STR | 1-ONE/2-TWO/3-THREE | 1000 FT REEL | |
Application & features
Power supply cable for VFDs and motors, suitable for cable tray (TC-ER rated), conduit, raceways, and machine tool wiring conforming to NFPA 79 2018. Suitable for free air and direct burial. It's flexible design is ideal or use on operation processes in accordance with he NEC® Articles 336, 501 and 502 including, but not limited to: fans, pumps, conveyors, compressors, elevators and lifts, extruders, crushers and presses, assembly lines, food and beverage, wind energy and data centers. Cable is rated for -40C Cold Bend and Impact. Multiple approvals for multiple applications.
Standards & references
- ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
- ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
- ASTM B174 Standard Specification for Bunch-Stranded Copper
- UL 44 Thermoset-Insulated Wires and Cables
- UL 1277 Type TC-ER Standard Power and Control Cables (1000V 14AWG and Larger)
- UL 2277 Flexible Motor Supply Cable and Wind Turbine Tray Cable
- CSA C22.2 No. 210 Appliance wiring material products I/II A/B (Sizes 16 - 8AWG)
- CSA C22.2 No.230 Tray Cables - Rated TC
- CSA C22.2 No. 239 Control and instrumentation cables
- ICEA S-138-738 Power Cables Rated 2000 Volts or Less for use Between Variable Frequency Drives and Motors
- CE/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011/65/EU) Directive
- Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661