DistributorSouthwire

Southwire

Southwire® Machine Flex® Power XLPE RW90

Southwire #
SPEC44069

Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry/Wet, -40°C. Flexible Bare Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (9) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)
3/0 AWG3/0 AWG11166616660.5331.35551.400.6031.53578860 45712699
4/0 AWG4/0 AWG11210921090.5201.32551.400.6421.637301086 45708499
250 KCMIL250 KCMIL116276270.6051.54651.650.7461.898501265 45708599
300 KCMIL300 KCMIL117417410.6381.62651.650.7781.9810201518 45708699
350 KCMIL350 KCMIL118938930.6701.70651.650.8102.0611791755 45708799
750 KCMIL750 KCMIL11185018501.0942.78802.031.2663.2225533799 13890699
3/0 AWG3/0 AWG0.0720.110.0870.130.0420.061342608.722.56.35200200225225 45712699
4/0 AWG4/0 AWG0.0570.080.0690.100.0410.061692767.482.66.60230230260260 45708499
250 KCMIL250 KCMIL0.0470.070.0570.080.0410.062000907.182.97.37255255290290 45708599
300 KCMIL300 KCMIL0.0390.060.0510.080.0410.0624001088.623.17.87285285320320 45708699
350 KCMIL350 KCMIL0.0330.050.0420.060.0400.0628001270.063.28.13310310350350 45708799
750 KCMIL750 KCMIL0.0160.020.0240.040.0380.0660002721.556.316.00475475535535 13890699

Part numbers in this family (9)

By size:
Southwire #DescriptionConstructionPackaging
3/0 AWG (3)
457126993/0-1672 CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER BLACK3/0 AWG 1C 1672SCUT TO LENGTH REEL
457128993/0-1672 CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER GREEN3/0 AWG 1C 1672SCUT TO LENGTH REEL
457127993/0-1672 CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER RED3/0 AWG 1C 1672SCUT TO LENGTH REEL
4/0 AWG (1)
457084994/0-2109 CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER BLACK4/0 AWG 1C 2109SCUT TO LENGTH REEL
250 kcmil (1)
45708599250-627 CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER BLACK250 KCMIL 1C 627SCUT TO LENGTH REEL
300 kcmil (1)
45708699300-741 CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER BLACK300 KCMIL 1C 741SCUT TO LENGTH REEL
350 kcmil (2)
45708799350-893 CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER BLACK350 KCMIL 1C 893SCUT TO LENGTH REEL
45714599350-893 CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER RED350 KCMIL 1C 893SCUT TO LENGTH REEL
750 kcmil (1)
13890699750-1850 CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER BLACK750 KCMIL 1C 1850SCUT TO LENGTH REEL

Application & features

Southwire Type XHHW-2 & RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 & RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible bare copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • CSA C22.2 No. 38 Thermoset-insulated wires and cables
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • CE/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011/65/EU) Directive
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661
  • Sunlight Resistance