Southwire® Machine Flex® Power XLPE RW90
- Southwire #
- SPEC44067
Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry/Wet, -40°C. Flexible Tinned Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (6) ↓Available sizes & constructions
| Cond. Size | Conductor Number | Cond. Strands | Diameter Over Conductor (in)(cm) | Insulation Thickness (mils)(mm) | Approx. OD (inches)(cm) | Approx. Weight (lbs/1000')(kgs/km) | ||
|---|---|---|---|---|---|---|---|---|
| 4/0 AWG4/0 AWG | 11 | 21092109 | 0.5501.40 | 551.40 | 0.6511.65 | 7131061 | 67296399 | |
| 250 KCMIL250 KCMIL | 11 | 608608 | 0.6051.54 | 651.65 | 0.7461.89 | 8481262 | 67291299 | |
| 350 KCMIL350 KCMIL | 11 | 888888 | 0.6701.70 | 651.65 | 0.8962.28 | 11771752 | 67291199 | |
| 500 KCMIL500 KCMIL | 11 | 12211221 | 0.8582.18 | 651.65 | 1.0362.63 | 16342432 | 67290699 | |
| 600 KCMIL600 KCMIL | 11 | 14801480 | 0.9632.45 | 802.03 | 1.1222.85 | 20233011 | 67204299 | |
| 750 KCMIL750 KCMIL | 11 | 18501850 | 1.0942.78 | 802.03 | 1.2623.21 | 25823842 | 67204399 | |
| 4/0 AWG4/0 AWG | 0.0570.08 | 0.0690.10 | 0.0410.06 | 1692767.48 | 2.66.60 | 230230 | 260260 | 67296399 |
| 250 KCMIL250 KCMIL | 0.0470.07 | 0.0570.08 | 0.0410.06 | 2000907.18 | 2.97.37 | 255255 | 290290 | 67291299 |
| 350 KCMIL350 KCMIL | 0.0330.05 | 0.0420.06 | 0.0400.06 | 28001270.06 | 3.58.89 | 310310 | 350350 | 67291199 |
| 500 KCMIL500 KCMIL | 0.0230.03 | 0.0310.05 | 0.0390.06 | 40001814.37 | 5.112.95 | 380380 | 430430 | 67290699 |
| 600 KCMIL600 KCMIL | 0.0190.03 | 0.0270.04 | 0.0390.06 | 48002177.24 | 5.614.22 | 420420 | 475475 | 67204299 |
| 750 KCMIL750 KCMIL | 0.0160.02 | 0.0240.04 | 0.0380.06 | 60002721.55 | 6.316.00 | 475475 | 535535 | 67204399 |
Part numbers in this family (6)
| Southwire # | Description | Construction | Packaging | |
|---|---|---|---|---|
| 67296399 | 4/0-2109 TINNED CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER BLACK | 4/0 AWG 1C 2109S | CUT TO LENGTH REEL | |
| 67291299 | 250-608 TINNED CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER BLACK | 250 KCMIL 1C 608S | CUT TO LENGTH REEL | |
| 67291199 | 350-888 TINNED CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER BLACK | 350 KCMIL 1C 888S | CUT TO LENGTH REEL | |
| 67290699 | 500-1221 TINNED CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER BLACK | 500 KCMIL 1C 1221S | CUT TO LENGTH REEL | |
| 67204299 | 600-1480 TINNED CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER BLACK | 600 KCMIL 1C 1480S | CUT TO LENGTH REEL | |
| 67204399 | 750-1850 TINNED CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER BLACK | 750 KCMIL 1C 1850S | CUT TO LENGTH REEL |
Application & features
Southwire Type XHHW-2 & RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 & RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible tinned copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.
Standards & references
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
- ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
- UL 44 Thermoset-Insulated Wires and Cables
- UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
- CSA C22.2 No. 38 Thermoset-insulated wires and cables
- ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
- CE/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011/65/EU) Directive
- Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661
- Sunlight Resistance