Southwire® Machine Flex® Power XLPE RW90

Southwire #
SPEC44067

Type XHHW-2 600 Volts or 1000 Volts and Type RW90 600V. Rated 90°C Dry/Wet, -40°C. Flexible Tinned Copper Conductors. Cross-Linked Polyethylene (XLPE) Insulation. Rated High-Heat, Flame, Moisture, Gasoline, Oil and Sunlight Resistant.

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (6) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)
4/0 AWG4/0 AWG11210921090.5501.40551.400.6511.657131061 67296399
250 KCMIL250 KCMIL116086080.6051.54651.650.7461.898481262 67291299
350 KCMIL350 KCMIL118888880.6701.70651.650.8962.2811771752 67291199
500 KCMIL500 KCMIL11122112210.8582.18651.651.0362.6316342432 67290699
600 KCMIL600 KCMIL11148014800.9632.45802.031.1222.8520233011 67204299
750 KCMIL750 KCMIL11185018501.0942.78802.031.2623.2125823842 67204399
4/0 AWG4/0 AWG0.0570.080.0690.100.0410.061692767.482.66.60230230260260 67296399
250 KCMIL250 KCMIL0.0470.070.0570.080.0410.062000907.182.97.37255255290290 67291299
350 KCMIL350 KCMIL0.0330.050.0420.060.0400.0628001270.063.58.89310310350350 67291199
500 KCMIL500 KCMIL0.0230.030.0310.050.0390.0640001814.375.112.95380380430430 67290699
600 KCMIL600 KCMIL0.0190.030.0270.040.0390.0648002177.245.614.22420420475475 67204299
750 KCMIL750 KCMIL0.0160.020.0240.040.0380.0660002721.556.316.00475475535535 67204399

Part numbers in this family (6)

By size:
Southwire #DescriptionConstructionPackaging
672963994/0-2109 TINNED CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER BLACK4/0 AWG 1C 2109SCUT TO LENGTH REEL
67291299250-608 TINNED CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER BLACK250 KCMIL 1C 608SCUT TO LENGTH REEL
67291199350-888 TINNED CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER BLACK350 KCMIL 1C 888SCUT TO LENGTH REEL
67290699500-1221 TINNED CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER BLACK500 KCMIL 1C 1221SCUT TO LENGTH REEL
67204299600-1480 TINNED CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER BLACK600 KCMIL 1C 1480SCUT TO LENGTH REEL
67204399750-1850 TINNED CU XHHW-2 1000V RW90 600V MACHINE FLEXIBLE POWER BLACK750 KCMIL 1C 1850SCUT TO LENGTH REEL

Application & features

Southwire Type XHHW-2 & RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for service, feeders, and branch circuit wiring as specified in the National Electric Code (NEC) and the Canadian Electrical Code (CE Code). XHHW-2 & RW90 conductors may be used at conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Voltage rating for XHHW-2 conductors is 600 volts and 1000 volts. Voltage rating for RW90 conductors is 600 volts. Flexible tinned copper stranding allows for ease of installation in locations with limited space, as well as including for use in electrical equipment for industrial facilities with harsh chemical environments, telecommunications applications and data centers.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • CSA C22.2 No. 38 Thermoset-insulated wires and cables
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • CE/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011/65/EU) Directive
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661
  • Sunlight Resistance