Southwire® Machine Flex® CU 600/1000V THHN Insulation Black TPE Jacket. Silicone-Free
- Southwire #
- SPEC45047
Type TC-ER Machine Tray Power Cable 600/1000 Volt Copper Conductors, Polyvinyl Chloride (PVC) with nylon layer Insulation Thermoplastic Elastomer Jacket, 90°C Dry 75°C Wet -40°C Cold Impact Identification Method 4. Silicone-Free
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (11) ↓Available sizes & constructions
| Cond. Size | Conductor Number | Cond. Strands | Diameter Over Conductor (in)(cm) | Insulation Thickness (mils)(mm) | Jacket Thickness (mils)(mm) | Approx. OD (inches)(cm) | Copper Weight (lbs/1000')(kgs/km) | Approx. Weight (lbs/1000')(kgs/km) | AC Resistance at 75C (ohms/1000')(ohms/km) | Min. Bend Radius (in)(cm) | Allowable Ampacity Raceway 75C | Allowable Ampacity Raceway 90C | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 8 AWG8 AWG | 33 | 168168 | 0.1530.39 | 300.76 | 651.65 | 0.6271.59 | 157234 | 316470 | 0.8611.28 | 2.56.35 | 5050 | 5555 | 65367299 |
| 8 AWG8 AWG | 44 | 168168 | 0.1530.39 | 300.76 | 651.65 | 0.7001.78 | 210313 | 375558 | 0.8611.28 | 2.87.11 | 4040 | 4444 | 67732399 |
| 8 AWG8 AWG | 55 | 168168 | 0.1530.39 | 300.76 | 651.65 | 0.7661.95 | 263391 | 451671 | 0.8611.28 | 3.07.62 | 4040 | 4444 | 65300799 |
| 6 AWG6 AWG | 44 | 259259 | 0.1980.50 | 300.76 | 651.65 | 0.8172.08 | 358533 | 564839 | 0.5410.81 | 3.28.13 | 5252 | 6060 | 67732499 |
| 4 AWG4 AWG | 44 | 420420 | 0.2350.60 | 401.02 | 802.03 | 0.9692.46 | 532792 | 8321238 | 0.3400.51 | 3.89.65 | 6868 | 7676 | 67732599 |
| 2 AWG2 AWG | 33 | 651651 | 0.3020.77 | 401.02 | 1002.54 | 1.0642.70 | 637948 | 9871469 | 0.2160.32 | 5.313.46 | 115115 | 130130 | 65296899 |
| 2 AWG2 AWG | 44 | 651651 | 0.3020.77 | 401.02 | 1002.54 | 1.1963.04 | 8491263 | 12671886 | 0.2160.32 | 5.914.99 | 9292 | 104104 | 67732699 |
| 1/0 AWG1/0 AWG | 33 | 10641064 | 0.3540.90 | 601.52 | 802.03 | 1.3183.35 | 12301830 | 16942521 | 0.1260.19 | 6.616.76 | 150150 | 170170 | 67429899 |
| 2/0 AWG2/0 AWG | 33 | 13301330 | 0.4001.02 | 601.52 | 802.03 | 1.4183.60 | 14852210 | 20213008 | 0.1010.15 | 7.118.03 | 175175 | 195195 | 67430099 |
| 350 KCMIL350 KCMIL | 33 | 893893 | 0.8092.05 | 701.78 | 1102.79 | 2.0195.13 | 34975204 | 44616639 | 0.0410.06 | 12.130.73 | 310310 | 350350 | 67757399 |
| 600 KCMIL600 KCMIL | 33 | 14801480 | 1.1252.86 | 802.03 | 1403.56 | 2.7096.88 | 58418692 | 720710725 | 0.0260.04 | 16.341.40 | 420420 | 475475 | 67757699 |
Part numbers in this family (11)
| Southwire # | Description | Construction | Conductor Color | Packaging | |
|---|---|---|---|---|---|
| 65367299 | 8-168 3/C CU PVC/NYLON CDRS/TPE PHASE ID TYPE TC-ER/WTTC/MTW FLEXING/DP-1 AWM 2587 600V BLACK | 8 AWG 3C 168 STR | 1-ONE/2-TWO | CUT TO LENGTH REEL | |
| 67732399 | 8-168 4/C CU PVC/NYLON CDRS/TPE PHASE ID TYPE TC-ER/WTTC/MTW FLEXING/DP-1 AWM 2587 600V BLACK | 8 AWG 4C 168S | BLACK/BLACK/BLACK/GREEN-YELLOWOW | CUT TO LENGTH REEL | |
| 65300799 | 8-168 5/C CU PVC/NYLON CDRS/TPE PHASE ID TYPE TC-ER/WTTC/MTW FLEXING/DP-1 AWM 2587 600V BLACK | 8 AWG 5C 168S | 1-ONE/2-TWO/3-THREE/4-FOUR/GREEN-YELLOW STRIPE/- | CUT TO LENGTH REEL | |
| 67732499 | 6-259 4/C CU PVC/NYLON CDRS/TPE PHASE ID TYPE TC-ER/WTTC/MTW FLEXING/DP-1 AWM 2587 600V BLACK | 6 AWG 4C 259S | BLACK/BLACK/BLACK/GREEN-YELLOWOW | CUT TO LENGTH REEL | |
| 67732599 | 4-420 4/C CU PVC/NYLON CDRS/TPE PHASE ID TYPE TC-ER/WTTC/MTW FLEXING/DP-1 AWM 2587 600V BLACK | 4 AWG 4C 420S | 1-ONE/2-TWO/3-THREE/GREEN-YELLOW STRIPE | CUT TO LENGTH REEL | |
| 65296899 | 2-651 3/C CU PVC/NYLON CDRS/TPE PHASE ID TYPE TC-ER/WTTC/MTW FLEXING/DP-1 AWM 2587 600V BLACK | 2 AWG 3C 651S | 1-ONE/2-TWO/GREEN-YELLOW STRIPE/- | CUT TO LENGTH REEL | |
| 67732699 | 2-651 4/C CU PVC/NYLON CDRS/TPE PHASE ID TYPE TC-ER/WTTC/MTW FLEXING/DP-1 AWM 2587 600V BLACK | 2 AWG 4C 651S | 1-ONE/2-TWO/3-THREE/GREEN-YELLOW STRIPE | CUT TO LENGTH REEL | |
| 67429899 | 1/0-1064 3/C CU THHN/TPE PHASE ID 1X#2 GG TYPE TC-ER/WTTC/MTW FLEXING/DP-1 AWM 20886 CSA AWM I/II A/B 600V BLACK | 1/0 AWG 3C 1064S | 1-ONE/2-TWO/3-THREE/GREEN-YELLOW STRIPE | CUT TO LENGTH REEL | |
| 67430099 | 2/0-1330 3/C CU THHN/TPE PHASE ID 1X#2 GG TYPE TC-ER/WTTC/MTW FLEXING/DP-1 AWM 20886 CSA AWM I/II A/B 600V BLACK | 2/0 AWG 3C 1330S | 1-ONE/2-TWO/3-THREE | CUT TO LENGTH REEL | |
| 67757399 | 350-893 3/C CU THHN/TPE PHASE ID 1X#2 GG TYPE TC-ER/WTTC/MTW FLEXING/DP-1 AWM 20886 CSA AWM I/II A/B 600V BLACK | 350 KCMIL 3C 893S | 1-ONE/2-TWO/3-THREE/GREEN-YELLOW STRIPE | CUT TO LENGTH REEL | |
| 67757699 | 600-1480 3/C CU THHN/TPE PHASE ID 1X#2 GG TYPE TC-ER/WTTC/MTW FLEXING/DP-1 AWM 20886 CSA AWM I/II A/B 600V BLACK | 600 KCMIL 3C 1480S | 1-ONE/2-TWO/3-THREE/GREEN-YELLOW STRIPE | CUT TO LENGTH REEL |
Application & features
Southwire’s Machine Flex® tray power cables 600/1000 Volt conform to NFPA 79 and are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial and where superior electrical properties are desired. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC® 336.10. These cables are capable of operating continuously at the conductor temperature not in excess of 75°C in wet locations and 90°C in dry locations, 130°C for emergency overload, and 150°C for short circuit conditions. For uses in Class I, II, Division 2 hazardous locations per NEC® Article 501 and 502. Southwire’s machine tray cable is ideal to power CNC machines, grinding, cutting, metal forming, buffing, bottling equipment, conveyors, processing & packaging equipment, assembly lines, control panels, food and beverage, oil sands, plant expansion, wind energy and data centers. Multiple approvals for multiple applications. Cable is rated for -40°C cold impact. Two conductor cables contain no green/yellow ground.
Standards & references
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
- ASTM B174 Standard Specification for Bunch-Stranded Copper
- UL 13 Power-Limited Circuit Cables
- UL 83 Thermoplastic Insulated Wires and Cables
- UL 758 AWM Style 2587
- UL 1277 TC-ER
- UL 1690 Data Processing Cable (DP-1)
- UL 2250 Instrumentation Tray Cable
- UL 2277 Type WTTC
- CSA C22.2 No. 210 Appliance wiring material products I/II A/B (Sizes 16 - 8AWG)
- CSA C22.2 No.230 Tray Cables - Rated TC
- CSA C22.2 No. 239 Control and instrumentation cables
- ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
- IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
- Exceeds Ecolab PM-40-1 Material Resistance Test With 30-day Exposure, UL Verified V747862
- CE/RoHS-2 – The CE Marking has been applied solely to express the conformance to the material restrictions identified in the RoHS-2 (2011/65/EU) Directive
- NFPA 79 Electrical Standard for Industrial Machinery
- Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661