PantoFLEX™ DC Power Cable 2/C CU 1000V XLPE Insulation PVC Jacket. TC-ER XHHW-2 with Green Ground
- Southwire #
- SPEC48050
Type TC-ER Control Cable 1000 Volt Copper Conductors, Cross-Linked Polyethylene Insulation XHHW-2, Polyvinyl Chloride (PVC) Jacket, Sunlight Resistant - For Direct Burial - Silicone Free
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (3) ↓Available sizes & constructions
| Cond. Size | Conductor Number | Cond. Strands | Diameter Over Conductor (in)(cm) | Insulation Thickness (mils)(mm) | Jacket Thickness (mils)(mm) | Approx. OD (inches)(cm) | Copper Weight (lbs/1000')(kgs/km) | Approx. Weight (lbs/1000')(kgs/km) | |
|---|---|---|---|---|---|---|---|---|---|
| 4/0 AWG4/0 AWG | 22 | 532532 | 0.5301.35 | 551.40 | 802.03 | 1.4903.78 | 14452150 | 18792796 | 66591299 |
| 250 KCMIL250 KCMIL | 22 | 627627 | 0.6051.54 | 651.65 | 802.03 | 1.6664.23 | 17132549 | 22113290 | 66593499 |
| 350 KCMIL350 KCMIL | 22 | 893893 | 0.6701.70 | 651.65 | 1102.79 | 1.8604.72 | 23603512 | 30374520 | 66591499 |
| 4/0 AWG4/0 AWG | 22 | 7.519.05 | 33851535.41 | 0.0550.08 | 0.0670.10 | 0.0410.06 | 230230 | 260260 | 66591299 |
| 250 KCMIL250 KCMIL | 22 | 8.321.08 | 40001814.37 | 0.0470.07 | 0.0570.08 | 0.0410.06 | 255255 | 290290 | 66593499 |
| 350 KCMIL350 KCMIL | 22 | 9.323.62 | 56002540.12 | 0.0330.05 | 0.0420.06 | 0.0400.06 | 310310 | 350350 | 66591499 |
Part numbers in this family (3)
| Southwire # | Description | Construction | Conductor Color | Packaging | |
|---|---|---|---|---|---|
| 66591299 | 4/0-532 2/C CU XHHW/PVC BLACK/RED 1x4 GG TYPE TC-ER 1000V BLACK PantoFLEX(TM) | 4/0 AWG 2C 532S | BLACK/RED | CUT TO LENGTH REEL | |
| 66593499 | 250-627 2/C CU XHHW/PVC BLACK/RED 1x3 GG TYPE TC-ER 1000V BLACK PantoFLEX(TM) | 250 KCMIL 2C 627S | BLACK/RED | CUT TO LENGTH REEL | |
| 66591499 | 350-893 2/C CU XHHW/PVC BLACK/RED 1x3 GG TYPE TC-ER 1000V BLACK PantoFLEX(TM) | 350 KCMIL 2C 893S | BLACK/RED | CUT TO LENGTH REEL |
Application & features
Southwire’s 1000 Volt Type TC-ER PantoFLEX™ DC Power Cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Type (TC-ER) per NEC 336.10. Silicone free.
Standards & references
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
- UL 44 Thermoset-Insulated Wires and Cables
- UL 1277 Type TC-ER Standard Power and Control Cables (1000V 14AWG and Larger)
- ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy