MC-PCS HCF Duo™ Power & Control/Signal Cable 277/480V Colors
- Southwire #
- SPEC60157
Copper THHN/THWN Insulated Singles. Green Insulated Copper Grounding Conductor. UL Listed 600 Volts. Rated VW-1. Lightweight Interlocked Armor. Signal: 16 AWG Copper TFN insulated singles.
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (13) ↓Available sizes & constructions
| Cond. Size | Conductor Number | Color | Diameter Over Conductor (in)(cm) | Cond. Strands | Insulation Thickness (mils)(mm) | Ground Size | Diameter Over Armor (in)(cm) | Approx. Weight (lbs/1000')(kgs/km) | |
|---|---|---|---|---|---|---|---|---|---|
| 12 AWG12 AWG | 22 | OE,GYOE,GY | 0.0800.20 | SolidSolid | 200.51 | 1x121x12 | 0.6321.61 | 164244 | 59766101 |
| 12 AWG12 AWG | 22 | BN,GYBN,GY | 0.0800.20 | 1919 | 200.51 | 1x121x12 | 0.6511.65 | 170253 | 59767501 |
| 12 AWG12 AWG | 33 | BN,OE,GYBN,OE,GY | 0.0800.20 | SolidSolid | 200.51 | 1x121x12 | 0.6741.71 | 193287 | 59766701 |
| 12 AWG12 AWG | 22 | 4.411.18 | 1.6622.47 | 2.0022.98 | 0.0540.08 | 2525 | 3030 | 59766101 | |
| 12 AWG12 AWG | 22 | 4.611.68 | 1.6622.47 | 2.0022.98 | 0.0540.08 | 2525 | 3030 | 59767501 | |
| 12 AWG12 AWG | 33 | 4.711.94 | 1.6622.47 | 2.0022.98 | 0.0540.08 | 2525 | 3030 | 59766701 |
Part numbers in this family (13)
| Southwire # | Description | Construction | Conductor Color | Packaging | |
|---|---|---|---|---|---|
| 12 AWG · 2 conductors (12) | |||||
| 59767501 | 12-2 STR CU THHN N/A/G 16-2 SOL TFN PR W/ LT BLUE PVC JKT 10 SOL BARE AL GRND AIA MCAP-HCF MC-PCS 250 FT | 12 AWG 2C 19 STR | BRN/GRY/GRN | 250 FT COIL | |
| 59812901 | 12-2 SOL CU THHN N/A/G 16-2 SOL TFN PR W/ LT BLUE PVC JKT 10 SOL BARE AL GRND AIA MCAP-HCF MC-PCS 250 FT | 12 AWG 2C SOL | BRN/GRY/GRN | 250 FT COIL | |
| 59767502 | 12-2 STR CU THHN N/A/G 16-2 SOL TFN PR W/ LT BLUE PVC JKT 10 SOL BARE AL GRND AIA MCAP-HCF MC-PCS 1000 FT | 12 AWG 2C 19 STR | BRN/GRY/GRN | 1000 FT REEL | |
| 59812902 | 12-2 SOL CU THHN N/A/G 16-2 SOL TFN PR W/ LT BLUE PVC JKT 10 SOL BARE AL GRND AIA MCAP-HCF MC-PCS 1000 FT | 12 AWG 2C SOL | BRN/GRY/GRN | 1000 FT REEL | |
| 59812903 | 12-2 SOL CU THHN N/A/G 16-2 SOL TFN PR W/ LT BLUE PVC JKT 10 SOL BARE AL GRND AIA MCAP-HCF MC-PCS 1000 FT | 12 AWG 2C SOL | BRN/GRY/GRN | 1000 FT DRUM | |
| 59812904 | 12-2 SOL CU THHN N/A/G 16-2 SOL TFN PR W/ LT BLUE PVC JKT 10 SOL BARE AL GRND AIA MCAP-HCF MC-PCS 2500 FT | 12 AWG 2C SOL | BRN/GRY/GRN | 2500 FT BOX | |
| 59766101 | 12-2 SOL CU THHN O/A/G 16-2 SOL TFN PR W/ LT BLUE PVC JKT 10 SOL BARE AL GRND AIA MCAP-HCF MC-PCS 250 FT | 12 AWG 2C SOL | ORG/GRY/GRN | 250 FT COIL | |
| 59766102 | 12-2 SOL CU THHN O/A/G 16-2 SOL TFN PR W/ LT BLUE PVC JKT 10 SOL BARE AL GRND AIA MCAP-HCF MC-PCS 1000 FT | 12 AWG 2C SOL | ORG/GRY/GRN | 1000 FT REEL | |
| 64109402 | 12-2 STR CU THHN O/A/G 16-2 SOL TFN PR W/ LT BLUE PVC JKT 10 SOL BARE AL GRND AIA MCAP-HCF MC-PCS 1000 FT | 12 AWG 2C 19 STR | ORG/GRY/GRN | 1000 FT REEL | |
| 59766301 | 12-2 SOL CU THHN Y/A/G 16-2 SOL TFN PR W/ LT BLUE PVC JKT 10 SOL BARE AL GRND AIA MCAP-HCF MC-PCS 250 FT | 12 AWG 2C SOL | YLW/GRY/GRN | 250 FT COIL | |
| 59766302 | 12-2 SOL CU THHN Y/A/G 16-2 SOL TFN PR W/ LT BLUE PVC JKT 10 SOL BARE AL GRND AIA MCAP-HCF MC-PCS 1000 FT | 12 AWG 2C SOL | YLW/GRY/GRN | 1000 FT REEL | |
| 64109602 | 12-2 STR CU THHN Y/A/G 16-2 SOL TFN PR W/ LT BLUE PVC JKT 10 SOL BARE AL GRND AIA MCAP-HCF MC-PCS 1000 FT | 12 AWG 2C 19 STR | YLW/GRY/GRN | 1000 FT REEL | |
| 12 AWG · 3 conductors (1) | |||||
| 59766701 | 12-3 SOL CU THHN N/O/A/G 16-2 SOL TFN PR W/ LT BLUE PVC JKT 10 SOL BAREAL GRND AIA MCAP-HCF MC-PCS 250 FT | 12 AWG 3C SOL | BRN/ORG/GRY/GRN | 250 FT COIL | |
Application & features
Southwire MC-PCS HCF Duo™ Type MC All Purpose Hospital Care Facility Cable is suitable for use as follows:
• Branch-circuit wiring for patient care areas of hospitals, medical centers, and other health care facilities (when installed in accordance with NEC® Articles 517 and 330, and mechanically protected per Article 300.4). Such areas include nursing homes, dental offices, clinics, and outpatient facilities. Use in hazardous anesthetizing areas is prohibited
• Applications requiring redundant, dedicated or isolated grounding paths
• Fished or embedded in plaster.
• Concealed or exposed installations
• Environmental air-handling spaces per NEC 300.22 (C)
• Places of Assembly per NEC 518.4 and theaters per NEC 520.5
• Power, lighting, control, and signal circuits
• Installation in cable tray and approved raceways
• Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2)
• Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations
• Use with UL Listed MCI-A fittings
• Binder tape with print legend wrapped around assembly
• Type THHN/THWN rated 90ºC dry
• Unjacketed Type MC cables are rated for dry, indoor locations only per NEC 330.10(A)(10)
Southwire MC-PCS HCF Duo™ Type MC Cable meets or exceeds the following requirements:
• UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )
• Federal Specification A-A59544 (formerly J-C-30B)
• NFPA 70 (National Electrical Code), Article 330
• Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems
Standards & references
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- ASTM B800 8000 Series Aluminum Alloy Wire
- UL 83 Thermoplastic Insulated Wires and Cables
- UL 1569 Metal-Clad Cables
- UL 1479 Standard for Safety Fire Tests of Penetration Firestops
- UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
- IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
- Buy American: Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j); specify “Made in the USA Only!” when ordering to ensure your project receives American made products.