MC-PCS Duo™ Power & Control/Signal Cable GSIA
- Southwire #
- SPEC60165
Copper THHN/THWN Insulated Singles. UL Listed 600 Volts. Rated VW-1. Galvanized Steel Interlocked Armor. Signal: 16 AWG Copper TFN insulated singles.
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (3) ↓Available sizes & constructions
| Cond. Size | Conductor Number | Color | Diameter Over Conductor (in)(cm) | Cond. Strands | Insulation Thickness (mils)(mm) | Ground Size | Diameter Over Armor (in)(cm) | Approx. Weight (lbs/1000')(kgs/km) | |
|---|---|---|---|---|---|---|---|---|---|
| 12 AWG12 AWG | 22 | BK,WEBK,WE | 0.0800.20 | SolidSolid | 200.51 | 1x121x12 | 0.6081.54 | 214318 | 59939601 |
| 12 AWG12 AWG | 33 | BK,OE,GYBK,OE,GY | 0.0800.20 | SolidSolid | 200.51 | 1x121x12 | 0.6501.65 | 249371 | 64752202 |
| 12 AWG12 AWG | 22 | 4.310.92 | 1.6622.47 | 2.0022.98 | 0.0540.08 | 2525 | 3030 | 59939601 | |
| 12 AWG12 AWG | 33 | 4.611.68 | 1.6622.47 | 2.0022.98 | 0.0540.08 | 2525 | 3030 | 64752202 |
Part numbers in this family (3)
| Southwire # | Description | Construction | Conductor Color | Packaging | |
|---|---|---|---|---|---|
| 12 AWG · 2 conductors (2) | |||||
| 59939601 | 12-2 SOL CU THHN B/W/G 16-2 SOL TFN PR W/ LT BLUE PVC JKT STEEL MC-PCS 250 FT | 12 AWG 2C SOL | BLK/WHT/GRN | 250 FT COIL | |
| 59939602 | 12-2 SOL CU THHN B/W/G 16-2 SOL TFN PR W/ LT BLUE PVC JKT STEEL MC-PCS 1000 FT | 12 AWG 2C SOL | BLK/WHT/GRN | 1000 FT REEL | |
| 12 AWG · 3 conductors (1) | |||||
| 64752202 | 12-3 SOL CU THHN N/O/A/G 16-2 SOL TFN PR W/ LT BLUE PVC JKT STEEL MC-PCS 1000 FT | 12 AWG 3C SOL | BRN/ORG/GRY/GRN | 1000 FT REEL | |
Application & features
Southwire MC PCS Duo™ Power & Control/Signal Galvanized Steel Armor cable is suitable for use as follows:
• Branch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings
• Fished or embedded in plaster
• Concealed or exposed installations
• LED lighting with 0-10V dimming
• Environmental air-handling spaces per NEC 300.22 (C)
• Places of Assembly per NEC 518.4 and theaters per NEC 520.5
• Installation in cable tray and approved raceways
• Under raised floors for information technology equipment conductors and cables per NEC 645
• Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations
• Binder tape with print legend wrapped around assembly
• Type THHN/THWN rated 90ºC dry
• Unjacketed Type MC cables are rated for dry, indoor locations only per NEC 330.10(A)(10)
• Anti-Short bushing not required
Southwire MC PCS Duo™ Type MC Cable meets or exceeds the following requirements:
• UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )
• Federal Specification A-A59544 (formerly J-C-30B)
• NFPA 70 (National Electrical Code), Article 330
• Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems
Standards & references
- ASTM B3 Soft or Annealed Copper Wire
- UL 83 Thermoplastic Insulated Wires and Cables
- UL 1569 Metal-Clad Cables
- UL 1479 Standard for Safety Fire Tests of Penetration Firestops
- UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
- IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
- Buy American: Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j); specify “Made in the USA Only!” when ordering to ensure your project receives American made products.