MC-AP™ HCF Type MC All Purpose Health Care Facility THHN/THWN Circuit Size Copper Conductor 120/208V Colors Green Aluminum Armor PVC Jacketed

Southwire #
SPEC60266

Copper THHN Insulated Conductors. Full-Sized Aluminum Equipment Grounding/Bonding Conductor. UL Listed 600 Volt. Rated VW1. Lightweight Aluminum Interlocked Armor is Part of Equipment Bonding/Grounding Path. PVC Jacketed

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (3) ↓

Available sizes & constructions

Cond. SizeConductor NumberColorDiameter Over Conductor (in)(cm)Cond. StrandsInsulation Thickness (mils)(mm)Ground SizeDiameter Over Armor (in)(cm)Jacket Thickness (mils)(mm)Approx. Weight (lbs/1000')(kgs/km)
12 AWG12 AWG22BK,WEBK,WE0.0800.20SolidSolid200.511x121x120.5121.30501.27186277 58495001
12 AWG12 AWG33BK,RD,WEBK,RD,WE0.0800.20SolidSolid200.511x121x120.5441.38501.27218324 59911101
12 AWG12 AWG224.310.921.6622.472.0022.980.0540.0825253030 58495001
12 AWG12 AWG334.511.431.6622.472.0022.980.0540.0825253030 59911101

Part numbers in this family (3)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
12 AWG · 2 conductors (2)
5849500112-2 SOL CU THHN BLACK/WHITE/GREEN GRND/10 AL GRND MCAP HCF JACKET BLACK PVC JACKET 250 FT12 AWG 2C SOLBLK/WHT/GRN250 FT COIL
5849500212-2 SOL CU THHN BLACK/WHITE/GREEN GRND/10 AL GRND MCAP HCF JACKET BLACK PVC JACKET 1000 FT12 AWG 2C SOLBLK/WHT/GRN1000 FT REEL
12 AWG · 3 conductors (1)
5991110112-3 SOL CU THHN BLACK/RED/WHITE/GREEN GRND/10 AL GRND MCAP HCF JACKET BLACK PVC JACKET 250 FT12 AWG 3C SOLBLK/RED/WHT/GRN250 FT COIL

Application & features

Southwire MC-AP HCF Type MC All Purpose Health Care Facility Cable is suitable for use as follows:

  • Branch-circuit wiring for patient care areas of hospitals, medical centers, and other health care facilities (when installed in accordance with NEC® Articles 517 and 330, and mechanically protected per Article 300.4). Such areas include nursing homes, dental offices, clinics, and outpatient facilities. Use in hazardous anesthetizing areas is prohibited.
  • Applications requiring redundant, dedicated or isolated grounding paths.
  • Fished or embedded in plaster.
  • Concealed or exposed installations.
  • Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
  • Installation in cable tray and approved raceways.
  • Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2)
  • Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.
  • Use with UL Listed MCI-A fittings.
  • Binder tape with print legend wrapped around assembly.
  • Type THHN/THWN rated 75ºC Wet 90ºC Dry.
  • Armor is in contact with aluminum grounding/bonding conductor and serves as a redundant equipment grounding path component

  • Southwire Armorlite® Type MC Cable - meets or exceeds the following requirements:
  • UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )
  • Federal Specification A-A59544 (formerly J-C-30B)
  • NFPA 70 (National Electrical Code), Article 330
  • Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems
  • Standards & references

    • ASTM B3 Soft or Annealed Copper Wire
    • ASTM B8 Concentric-Lay-Stranded Copper Conductors
    • UL 83 Thermoplastic Insulated Wires and Cables
    • UL 1569 Metal-Clad Cables
    • UL 1479 Standard for Safety Fire Tests of Penetration Firestops
    • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
    • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
    • RoHS-2 (European Directive 2011/65/EU)
    • Buy American: Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j); specify “Made in the USA Only!” when ordering to ensure your project receives American made products.