Copper THHN Insulated Conductors. Full-Sized Aluminum Equipment Grounding/Bonding Conductor. UL Listed 600 Volt. Rated VW1. Duraclad™ Green Galvanized Steel Interlocked Armor is Part of Equipment Bonding/Grounding Path.
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (15) ↓Available sizes & constructions
| Cond. Size | Conductor Number | Color | Diameter Over Conductor (in)(cm) | Cond. Strands | Insulation Thickness (mils)(mm) | Ground Size | Diameter Over Armor (in)(cm) | Approx. Weight (lbs/1000')(kgs/km) | |
|---|---|---|---|---|---|---|---|---|---|
| 12 AWG12 AWG | 22 | BK,WEBK,WE | 0.0800.20 | SolidSolid | 200.51 | 1x121x12 | 0.5121.30 | 188280 | 58232501 |
| 12 AWG12 AWG | 22 | BK,WEBK,WE | 0.0900.23 | 1919 | 200.51 | 1x121x12 | 0.5181.32 | 191284 | 58232701 |
| 12 AWG12 AWG | 33 | BK,RD,WEBK,RD,WE | 0.0800.20 | SolidSolid | 200.51 | 1x121x12 | 0.5441.38 | 222330 | 58232601 |
| 12 AWG12 AWG | 33 | BK,RD,WEBK,RD,WE | 0.0900.23 | 1919 | 200.51 | 1x121x12 | 0.5501.40 | 225335 | 58233501 |
| 10 AWG10 AWG | 22 | BK,WEBK,WE | 0.1010.26 | SolidSolid | 250.64 | 1x101x10 | 0.5711.45 | 245365 | 58233102 |
| 10 AWG10 AWG | 33 | BK,RD,WEBK,RD,WE | 0.1010.26 | SolidSolid | 250.64 | 1x101x10 | 0.6251.59 | 293436 | 58233401 |
| 12 AWG12 AWG | 22 | 3.69.14 | 1.6622.47 | 2.0022.98 | 0.0540.08 | 2525 | 3030 | 58232501 | |
| 12 AWG12 AWG | 22 | 3.69.14 | 1.6622.47 | 2.0022.98 | 0.0540.08 | 2525 | 3030 | 58232701 | |
| 12 AWG12 AWG | 33 | 3.89.65 | 1.6622.47 | 2.0022.98 | 0.0540.08 | 2525 | 3030 | 58232601 | |
| 12 AWG12 AWG | 33 | 3.99.91 | 1.6622.47 | 2.0022.98 | 0.0540.08 | 2525 | 3030 | 58233501 | |
| 10 AWG10 AWG | 22 | 4.010.16 | 1.0401.55 | 1.2531.86 | 0.0500.07 | 3535 | 4040 | 58233102 | |
| 10 AWG10 AWG | 33 | 4.411.18 | 1.0401.55 | 1.2531.86 | 0.0500.07 | 3535 | 4040 | 58233401 |
Part numbers in this family (15)
| Southwire # | Description | Construction | Conductor Color | Packaging | |
|---|---|---|---|---|---|
| 12 AWG · 2 conductors (9) | |||||
| 58232501 | 12-2 SOL CU THHN BLACK/WHITE/GREEN GRND/AL GRND MCAP HCF HCF GREEN GSIA250 FT | 12 AWG 2C SOL | BLK/WHT/GRN | 250 FT COIL | |
| 58232701 | 12-2 STR CU THHN BLACK/WHITE/GREEN GRND/AL GRND MCAP HCF GREEN GSIA 250FT | 12 AWG 2C 19 STR | BLK/WHT/GRN | 250 FT COIL | |
| 58232502 | 12-2 SOL CU THHN BLACK/WHITE/GREEN GRND/AL GRND MCAP HCF HCF GREEN GSIA1000 FT | 12 AWG 2C SOL | BLK/WHT/GRN | 1000 FT REEL | |
| 58232702 | 12-2 STR CU THHN BLACK/WHITE/GREEN GRND/AL GRND MCAP HCF GREEN GSIA 1000 FT | 12 AWG 2C 19 STR | BLK/WHT/GRN | 1000 FT REEL | |
| 58634101 | 12-2 SOL CU THHN BLUE/WHITE/GREEN GRND/AL GRND MCAP HCF GREEN GSIA 250 FT | 12 AWG 2C SOL | BLU/WHT/GRN | 250 FT COIL | |
| 58634102 | 12-2 SOL CU THHN BLUE/WHITE/GREEN GRND/AL GRND MCAP HCF GREEN GSIA 1000FT | 12 AWG 2C SOL | BLU/WHT/GRN | 1000 FT REEL | |
| 58232801 | 12-2 SOL CU THHN BROWN/GRAY/GREEN GRND/AL GRND MC HCF GREEN GSIA 250 FT | 12 AWG 2C SOL | BRN/GRY/GRN | 250 FT COIL | |
| 58232802 | 12-2 SOL CU THHN BROWN/GRAY/GREEN GRND/AL GRND MC HCF GREEN GSIA 1000 FT | 12 AWG 2C SOL | BRN/GRY/GRN | 1000 FT REEL | |
| 58633802 | 12-2 SOL CU THHN RED/WHITE/GREEN GRND/AL GRND MCAP HCF GREEN GSIA 1000 FT | 12 AWG 2C SOL | RED/WHT/GRN | 1000 FT REEL | |
| 12 AWG · 3 conductors (3) | |||||
| 58232601 | 12-3 SOL CU THHN BLACK/RED/WHITE/GREEN GRND/AL GRND MCAP HCF GREEN GSIA250 FT | 12 AWG 3C SOL | BLK/RED/WHT/GRN | 250 FT COIL | |
| 58232602 | 12-3 SOL CU THHN BLACK/RED/WHITE/GREEN GRND/AL GRND MCAP HCF GREEN GSIA1000 FT | 12 AWG 3C SOL | BLK/RED/WHT/GRN | 1000 FT REEL | |
| 58233501 | 12-3 STR CU THHN BLACK/WHITE/RED/GREEN GRND/AL GRND MCAP HCF GREEN GSIA250 FT | 12 AWG 3C 19 STR | BLK/WHT/RED/GRN | 250 FT COIL | |
| 10 AWG · 2 conductors (1) | |||||
| 58233102 | 10-2 SOL CU THHN BLACK/WHITE/GREEN GRND/AL GRND MCAP HCF GREEN GSIA 1000 FT | 10 AWG 2C SOL | BLK/WHT/GRN | 1000 FT REEL | |
| 10 AWG · 3 conductors (2) | |||||
| 58233401 | 10-3 SOL CU THHN BLACK/RED/WHITE/GREEN GRND/AL GRND MCAP HCF HCF GREEN GSIA 250 FT | 10 AWG 3C SOL | BLK/RED/WHT/GRN | 250 FT COIL | |
| 58233402 | 10-3 SOL CU THHN BLACK/RED/WHITE/GREEN GRND/AL GRND MCAP HCF HCF GREEN GSIA 1000 FT | 10 AWG 3C SOL | BLK/RED/WHT/GRN | 1000 FT REEL | |
Application & features
Southwire MC-AP HCF Type MC All Purpose Health Care Facility Cable is suitable for use as follows:
- Branch-circuit wiring for patient care areas of hospitals, medical centers, and other health care
facilities (when installed in accordance with NEC® Articles 517 and 330, and mechanically protected per Article 300.4). Such areas include nursing homes, dental offices, clinics, and outpatient facilities. Use in hazardous anesthetizing areas is prohibited.
- Applications requiring redundant, dedicated or isolated grounding paths.
- Fished or embedded in plaster.
- Concealed or exposed installations.
- Environmental air-handling spaces per NEC 300.22 (C).
- Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
- Installation in cable tray and approved raceways.
- Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2)
- Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.
- Use with UL Listed MCI-A fittings.
- Binder tape with print legend wrapped around assembly.
- Type THHN/THWN rated 90ºC Dry.
- Green galvanized steel interlocked armor
- Armor is in contact with aluminum grounding/bonding conductor and serves as a redundant equipment grounding path component
Southwire Armorlite® Type MC Cable - meets or exceeds the following requirements:
- UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )
- Federal Specification A-A59544 (formerly J-C-30B)
- NFPA 70 (National Electrical Code), Article 330
- Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems
Standards & references
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- UL 83 Thermoplastic Insulated Wires and Cables
- UL 1569 Metal-Clad Cables
- UL 1479 Standard for Safety Fire Tests of Penetration Firestops
- UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
- IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
- RoHS-2 (European Directive 2011/65/EU)
- Buy American: Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j); specify “Made in the USA Only!” when ordering to ensure your project receives American made products.