FLEXTOR™ CU 600V PVC-Nylon Insulation PVC Jacket THHN/THWN-2. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free

Southwire #
SPEC45260

Type TC-ER Power Cable Flexible 600Volt Four Conductor Copper, Polyvinyl Chloride (PVC) with nylon layer insulation THHN Polyvinyl Chloride (PVC) Jacket with 1 Green Insulated CU Ground. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (2) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Copper Weight (lbs/1000')(kgs/km)Approx. Weight (lbs/1000')(kgs/km)
4 AWG4 AWG4419190.2260.57501.27802.031.0192.595728518641286 66936799
2 AWG2 AWG4419190.2860.73401.02802.031.1582.94909135312431850 64369799
4 AWG4 AWG445.112.951068484.440.2580.380.3100.460.0480.0768687676 66936799
2 AWG2 AWG445.814.731698770.200.1620.240.1950.290.0450.079292104104 64369799

Part numbers in this family (2)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
669367994-19 4/C CU THHN/PVC BROWN/ORANGE/YELLOW/GRAY 1x8 GG TYPE TC-ER 600V BLACK4 AWG 4C 19SBROWN/ORANGE/YELLOW/GRAYCUT TO LENGTH REEL
643697992-19 4/C CU THHN/PVC BROWN/ORANGE/YELLOW/GRAY 1X#6 GG TYPE TC-ER 600V BLACK2 AWG 4C 19SBROWN/ORANGE/YELLOW/GRAYCUT TO LENGTH REEL

Application & features

Southwire’s 600 Volt Type TC-ER flexible power cables are made with class C copper stranding for extra flexibilty suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 75°C in wet locations and 90°C in dry locations, 105°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. Sunlight Resistant - For Direct Burial - Silicone Free

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 83 Thermoplastic Insulated Wires and Cables
  • UL 1277 Electrical Power and Control Tray Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu/hr) and ICEA T-29-520 - (210,000 Btu/hr)