FLEXTOR™ CU 600V PVC-Nylon Insulation PVC Jacket THHN/THWN-2. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free
- Southwire #
- SPEC45260
Type TC-ER Power Cable Flexible 600Volt Four Conductor Copper, Polyvinyl Chloride (PVC) with nylon layer insulation THHN Polyvinyl Chloride (PVC) Jacket with 1 Green Insulated CU Ground. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (2) ↓Available sizes & constructions
| Cond. Size | Conductor Number | Cond. Strands | Diameter Over Conductor (in)(cm) | Insulation Thickness (mils)(mm) | Jacket Thickness (mils)(mm) | Approx. OD (inches)(cm) | Copper Weight (lbs/1000')(kgs/km) | Approx. Weight (lbs/1000')(kgs/km) | |
|---|---|---|---|---|---|---|---|---|---|
| 4 AWG4 AWG | 44 | 1919 | 0.2260.57 | 501.27 | 802.03 | 1.0192.59 | 572851 | 8641286 | 66936799 |
| 2 AWG2 AWG | 44 | 1919 | 0.2860.73 | 401.02 | 802.03 | 1.1582.94 | 9091353 | 12431850 | 64369799 |
| 4 AWG4 AWG | 44 | 5.112.95 | 1068484.44 | 0.2580.38 | 0.3100.46 | 0.0480.07 | 6868 | 7676 | 66936799 |
| 2 AWG2 AWG | 44 | 5.814.73 | 1698770.20 | 0.1620.24 | 0.1950.29 | 0.0450.07 | 9292 | 104104 | 64369799 |
Part numbers in this family (2)
| Southwire # | Description | Construction | Conductor Color | Packaging | |
|---|---|---|---|---|---|
| 66936799 | 4-19 4/C CU THHN/PVC BROWN/ORANGE/YELLOW/GRAY 1x8 GG TYPE TC-ER 600V BLACK | 4 AWG 4C 19S | BROWN/ORANGE/YELLOW/GRAY | CUT TO LENGTH REEL | |
| 64369799 | 2-19 4/C CU THHN/PVC BROWN/ORANGE/YELLOW/GRAY 1X#6 GG TYPE TC-ER 600V BLACK | 2 AWG 4C 19S | BROWN/ORANGE/YELLOW/GRAY | CUT TO LENGTH REEL |
Application & features
Southwire’s 600 Volt Type TC-ER flexible power cables are made with class C copper stranding for extra flexibilty suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 75°C in wet locations and 90°C in dry locations, 105°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. Sunlight Resistant - For Direct Burial - Silicone Free
Standards & references
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- UL 83 Thermoplastic Insulated Wires and Cables
- UL 1277 Electrical Power and Control Tray Cables
- UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
- ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
- ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
- IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu/hr) and ICEA T-29-520 - (210,000 Btu/hr)