DistributorSouthwire

Southwire

Fire Alarm Shielded Cable, Riser

Southwire #
GEN16

Genesis® Fire Alarm Cables ensure uninterrupted fire protection. Built to exceed the demands of rigorous fire safety codes and regulations, UL listed, and Made in the USA.

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (14) ↓

Available sizes & constructions

Size (AWG or kcmil)(mm2)No. of ConductorsStrandingShieldingNominal Total Weight (lbs/1000')(kgs/km)
18 AWG18 AWG22SolidSolidShieldedShielded1725 44021004
18 AWG18 AWG44SolidSolidShieldedShielded2841 44031104
16 AWG16 AWG22SolidSolidShieldedShielded2537 44061004
16 AWG16 AWG44SolidSolidShieldedShielded4364 44071004
14 AWG14 AWG22SolidSolidShieldedShielded3653 44081004
14 AWG14 AWG44SolidSolidShieldedShielded6596 44091004
12 AWG12 AWG22SolidSolidShieldedShielded5785 44101004

Part numbers in this family (14)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
18 AWG · 2 conductors (3)
4402550418 SOL CU 2/C OAS CMR/CL3R/FPLR PVC RED GEN 500 FT18 AWG 2C SOLRED/BLACK500 FT PULL OUT BOX
4402100418 SOL CU 2/C OAS CMR/CL3R/FPLR PVC RED GEN 1000 FT18 AWG 2C SOLRED/BLACK1000 FT REEL
4402110418 SOL CU 2/C OAS CMR/CL3R/FPLR PVC RED GEN 1000 FT18 AWG 2C SOLRED/BLACK1000 FT PULL OUT BOX
18 AWG · 4 conductors (2)
4403550418 SOL CU 4/C OAS CMR/CL3R/FPLR PVC RED GEN 500 FT18 AWG 4C SOLYELLOW/RED/GREEN/BLACK500 FT PULL OUT BOX
4403110418 SOL CU 4/C OAS CMR/CL3R/FPLR PVC RED GEN 1000 FT18 AWG 4C SOLYELLOW/RED/GREEN/BLACK1000 FT PULL OUT BOX
16 AWG · 2 conductors (4)
4406550416 SOL CU 2/C OAS CMR/CL3R/FPLR PVC RED GEN 500 FT16 AWG 2C SOLRED/BLACK500 FT PULL OUT BOX
4406100416 SOL CU 2/C OAS CMR/CL3R/FPLR PVC RED GEN 1000 FT16 AWG 2C SOLRED/BLACK1000 FT REEL
4406100616 SOL CU 2/C OAS CMR/CL3R/FPLR PVC BLUE GEN 1000 FT16 AWG 2C SOLRED/BLACK1000 FT REEL
4406110416 SOL CU 2/C OAS CMR/CL3R/FPLR PVC RED GEN 1000 FT16 AWG 2C SOLRED/BLACK1000 FT PULL OUT BOX
16 AWG · 4 conductors (1)
4407100416 SOL CU 4/C OAS CMR/CL3R/FPLR PVC RED GEN 1000 FT16 AWG 4C SOLYELLOW/RED/GREEN/BLACK1000 FT REEL
14 AWG · 2 conductors (2)
4408500414 SOL CU 2/C OAS CL3R/FPLR PVC RED GEN 500 FT14 AWG 2C SOLRED/BLACK500 FT REEL
4408100414 SOL CU 2/C OAS CL3R/FPLR PVC RED GEN 1000 FT14 AWG 2C SOLRED/BLACK1000 FT REEL
14 AWG · 4 conductors (1)
4409100414 SOL CU 4/C OAS CL3R/FPLR PVC RED GEN 1000 FT14 AWG 4C SOLYELLOW/RED/GREEN/BLACK1000 FT REEL
12 AWG · 2 conductors (1)
4410100412 SOL CU 2/C OAS CL3R/FPLR PVC RED GEN 1000 FT12 AWG 2C SOLRED/BLACK1000 FT REEL

Application & features

Genesis® Riser Rated Shielded Fire Alarm Cable is suitable for installation as follows:

  • Installed in a metal raceway that complies with 300.22(B).
  • Supported by solid bottom metal cable trays with solid metal covers.
  • In risers.
  • Within buildings in other than air-handling spaces and risers.
  • Exposed to sunlight.

Standards & references

  • UL 1666 - Riser Rated
  • CSA C22.2 No. 2556 - FT4 Rated
  • UL 1424 - Cables for Power-Limited Fire-Alarm Circuits, Type FPLR
  • UL 13 - Power-Limited Circuit Cables, Type CL3R
  • Sunlight Resistant Rated
  • REACH/RoHS Compliant