DistributorSouthwire

Southwire

EZ-IN™ Mini-Split Shielded Cable

Southwire #
SPEC60422

Copper Insulated Singles. Green Insulated Copper Grounding Conductor. UL Listed. 600 Volts. Lightweight Aluminum Interlocked Armor. PVC Jacketed, Sunlight Resistant.

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (4) ↓

Available sizes & constructions

Cond. SizeConductor NumberColorDiameter Over Conductor (in)(cm)Cond. StrandsInsulation Thickness (mils)(mm)Diameter Over Armor (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)
14 AWG14 AWG44BK,RD,WE,GNBK,RD,WE,GN0.0700.1877200.510.4841.23501.270.5901.50175260 59351201
14 AWG14 AWG444.110.412.6313.923.2644.8620202525 59351201

Part numbers in this family (4)

Southwire #DescriptionConstructionConductor ColorPackaging
14 AWG (4)
5935120314-4 STR THHN DW AL SHLD AIA PVC EZ-IN 600V 50 FT14 AWG 4C 7 STRBLK/RED/GRN/WHT50 FT COIL
5935120414-4 STR THHN DW AL SHLD AIA PVC EZ-IN 600V 100 FT14 AWG 4C 7 STRBLK/RED/GRN/WHT100 FT REEL
5935120214-4 STR THHN DW AL SHLD AIA PVC EZ-IN 600V 250 FT14 AWG 4C 7 STRBLK/RED/GRN/WHT250 FT REEL
5935120114-4 STR THHN DW AL SHLD AIA PVC EZ-IN 600V 1000 FT14 AWG 4C 7 STRBLK/RED/GRN/WHT1000 FT REEL

Application & features

Southwire EZ-IN™ Mini-Split Jacketed Type MC Cable is suitable for use as follows:
- Where exposed to cinder fills, strong chlorides, caustic alkalis, or vapors of chlorine or of hydrochloric acids.
- Fished or embedded in plaster.
- Installed without the use of conduit.
- Concealed or exposed installations.
- Suitable for Wet Location per NEC 330.10(11)
- Installation in cable tray and approved raceways, or as aerial cable on a messenger.
- Type THHN/THWN/TFN rated 90ºC Dry/ 75ºC Wet
- Anti-Short bushing not required

Southwire EZ-IN™ Mini-Split Cable - meets or exceeds the following requirements:
- UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )
- Federal Specification A-A59544 (formerly J-C-30B)
- NFPA 70 (National Electrical Code), Article 330

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 83 Thermoplastic Insulated Wires and Cables
  • UL 1569 Metal-Clad Cables
  • Buy American: Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j); specify “Made in the USA Only!” when ordering to ensure your project receives American made products.