EZ-IN™ Mini-Split Cable
- Southwire #
- SPEC60421
Copper Insulated Singles. Green Insulated Copper Grounding Conductor. UL Listed. 600 Volts. Lightweight Aluminum Interlocked Armor. PVC Jacketed, Sunlight Resistant.
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (8) ↓Available sizes & constructions
| Cond. Size | Conductor Number | Color | Diameter Over Conductor (in)(cm) | Cond. Strands | Insulation Thickness (mils)(mm) | Diameter Over Armor (in)(cm) | Jacket Thickness (mils)(mm) | Approx. OD (inches)(cm) | Approx. Weight (lbs/1000')(kgs/km) | |
|---|---|---|---|---|---|---|---|---|---|---|
| 16 AWG16 AWG | 44 | BK,RD,WE,GNBK,RD,WE,GN | 0.0560.14 | 77 | 200.51 | 0.4451.13 | 401.02 | 0.5251.33 | 124185 | 58628801 |
| 14 AWG14 AWG | 44 | BK,RD,WE,GNBK,RD,WE,GN | 0.0700.18 | 77 | 200.51 | 0.4791.22 | 501.27 | 0.5851.49 | 166247 | 58340801 |
| 14 AWG14 AWG | 77 | BK,RD,BE,BN,OE,YW,RD/BK,WE,GNBK,RD,BE,BN,OE,YW,RD/BK,WE,GN | 0.0700.18 | 77 | 200.51 | 0.5441.38 | 501.27 | 0.6501.65 | 231344 | 58341001 |
| 16 AWG16 AWG | 44 | 3.69.14 | 4.1816.22 | 5.0377.50 | -- | 1818 | 58628801 | |||
| 14 AWG14 AWG | 44 | 4.010.16 | 2.6313.92 | 3.1704.72 | 2020 | 2525 | 58340801 | |||
| 14 AWG14 AWG | 77 | 4.511.43 | 2.6313.92 | 3.1704.72 | 1414 | 1717 | 58341001 |
Part numbers in this family (8)
| Southwire # | Description | Construction | Conductor Color | Packaging | |
|---|---|---|---|---|---|
| 16 AWG · 4 conductors (3) | |||||
| 58628801 | 16/4 TFN AIA PVC EZ-IN Mini-Split 600V 50 FT | 16 AWG 4C 7 STR | RED, BLK, WHT, GRN | 50 FT COIL | |
| 58628802 | 16/4 TFN AIA PVC EZ-IN Mini-Split 600V 250 FT | 16 AWG 4C 7 STR | RED/BLK/WHT/GRN | 250 FT REEL | |
| 58628803 | 16/4 TFN AIA PVC EZ-IN Mini-Split 600V 1000 FT | 16 AWG 4C 7 STR | RED/BLK/WHT/GRN | 1000 FT REEL | |
| 14 AWG · 4 conductors (3) | |||||
| 58340803 | 14/4 THHN AIA PVC EZ-IN Mini-Split 600V 50 FT | 14 AWG 4C 7 STR | BLK, RED, GRN, WHT | 50 FT COIL | |
| 58340802 | 14/4 THHN AIA PVC EZ-IN Mini-Split 600V 250 FT | 14 AWG 4C 7 STR | BLK/RED/GRN/WHT | 250 FT REEL | |
| 58340801 | 14/4 THHN AIA PVC EZ-IN Mini-Split 600V 1000 FT | 14 AWG 4C 7 STR | BLK/RED/GRN/WHT | 1000 FT REEL | |
| 14 AWG · 7 conductors (2) | |||||
| 58341099 | 14-7 STR CU THHN AIA MC MINI-SPLIT BLACK JKT 600V | 14 AWG 7C 7S | BLK/RED/BLU/ORG/YLW/BRN/RED-BLK/GRN | CUT TO LENGTH REEL | |
| 58341001 | 14-7 STR CU THHN AIA MC MINI-SPLIT BLACK JKT 600V 1000 FT | 14 AWG 7C 7S | BLK/RED/BLU/ORG/YLW/BRN/RED-BLK/GRN | 1000 FT REEL | |
Application & features
Southwire EZ-IN™ Mini-Split Jacketed Type MC Cable is suitable for use as follows:
- Where exposed to cinder fills, strong chlorides, caustic alkalis, or vapors of chlorine or of hydrochloric acids.
- Fished or embedded in plaster.
- Installed without the use of conduit.
- Concealed or exposed installations.
- Suitable for Wet Location per NEC 330.10(A)(11)
- Installation in cable tray and approved raceways, or as aerial cable on a messenger.
- Type THHN/THWN/TFN rated 90ºC Dry/ 75ºC Wet
- Anti-Short bushing not required
Southwire EZ-IN™ Mini-Split Cable - meets or exceeds the following requirements:
- UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )
- Federal Specification A-A59544 (formerly J-C-30B)
- NFPA 70 (National Electrical Code), Article 330
Standards & references
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- UL 83 Thermoplastic Insulated Wires and Cables
- UL 1569 Metal-Clad Cables
- UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
- IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
- RoHS-3 Complies with European Directive 2015/863
- Buy American: Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j); specify “Made in the USA Only!” when ordering to ensure your project receives American made products.