DistributorSouthwire

Southwire

DURATRAY™ CU 1000V XLPE Insulation. RHH/RHW-2/RW90 UL & CSA

Southwire #
SPEC25075

Single Copper Conductors, XLPE Insulation, Sunlight Resistant, 1000V, 90ºC MAX, -40ºC MIN, Gasoline & Oil Resistant

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (9) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Approx. OD (inches)(cm)Copper Weight (lbs/1000')(kgs/km)Approx. Weight (lbs/1000')(kgs/km)
1/0 AWG1/0 AWG1119190.3610.92802.030.5281.34326485394586 69414099
2/0 AWG2/0 AWG1119190.4051.03802.030.5721.45410610486723 64908999
3/0 AWG3/0 AWG1119190.4561.16802.030.6221.58518771601894 64914999
4/0 AWG4/0 AWG1119190.5121.30802.030.6661.696539727431106 64909899
350 KCMIL350 KCMIL1137370.6611.68952.410.8412.141080160712161810 64910801
500 KCMIL500 KCMIL1137370.7892.00952.410.9662.451543229617022533 64904799
750 KCMIL750 KCMIL1161610.9682.461102.791.2003.052315344525443786 64904999
1000 KCMIL1000 KCMIL1161611.1172.841102.791.3493.433087459433494984 64913199
1/0 AWG1/0 AWG112.15.33844382.830.1020.150.1220.180.0440.07150150170170 69414099
2/0 AWG2/0 AWG112.25.591064482.620.0810.120.0970.140.0430.06175175195195 64908999
3/0 AWG3/0 AWG112.46.101342608.720.0640.100.0780.120.0420.06200200225225 64914999
4/0 AWG4/0 AWG112.66.601692767.480.0510.080.0620.090.0410.06230230260260 64909899
350 KCMIL350 KCMIL113.38.3828001270.060.0310.050.0390.060.0400.06310310350350 64910801
500 KCMIL500 KCMIL113.89.6540001814.370.0220.030.0290.040.0390.06380380430430 64904799
750 KCMIL750 KCMIL116.015.2460002721.550.0140.020.0220.030.0380.06475475535535 64904999
1000 KCMIL1000 KCMIL116.717.0280003628.740.0110.020.0180.030.0370.06545545615615 64913199
1/01/0649133649133649135649135649138649138TBATBATBATBATBATBATBATBA
2/02/0649082649082649084649084649086649086TBATBATBATBATBATBATBATBA
3/03/0649142649142649144649144649147649147TBATBATBATBATBATBATBATBA
4/04/0649091649091649093649093649096649096TBATBATBATBATBATBATBATBA
250Kcmil250KcmilTBATBATBATBATBATBATBATBATBATBATBATBATBATBATBATBA
350Kcmil350Kcmil649101649101649104649104649106649106TBATBATBATBATBATBATBATBA
500Kcmil500Kcmil649112649112649114649114649116649116TBATBATBATBATBATBATBATBA
750Kcmil750Kcmil649118649118649120649120649122649122TBATBATBATBATBATBATBATBA
1000Kcmil1000Kcmil649124649124649126649126649128649128TBATBATBATBATBATBATBATBA

Part numbers in this family (9)

By size:
Southwire #DescriptionConstructionPackaging
1/0 AWG (1)
694140991/0-19 CU RHH-RHW-2 RW90 1KV DURATRAY BLACK UL/CSA1/0 AWG 1C 19SCUT TO LENGTH REEL
2/0 AWG (1)
649089992/0-19 CU RHH-RHW-2 RW90 1KV DURATRAY BLACK UL/CSA2/0 AWG 1C 19SCUT TO LENGTH REEL
3/0 AWG (1)
649149993/0-19 CU RHH-RHW-2 RW90 1KV DURATRAY BLACK UL/CSA3/0 AWG 1C 19SCUT TO LENGTH REEL
4/0 AWG (1)
649098994/0-19 CU RHH-RHW-2 RW90 1KV DURATRAY BLACK UL/CSA4/0 AWG 1C 19SCUT TO LENGTH REEL
350 kcmil (2)
64910899350-37 CU RHH-RHW-2 RW90 1KV DURATRAY BLACK UL/CSA 0 FT350 KCMIL 1C 37SCUT TO LENGTH REEL
64910801350-37 CU RHH-RHW-2 RW90 1KV DURATRAY BLACK UL/CSA 4921 FT350 KCMIL 1C 37S4921 FT REEL
500 kcmil (1)
64904799500-37 CU RHH-RHW-2 RW90 1KV DURATRAY BLACK UL/CSA500 KCMIL 1C 37SCUT TO LENGTH REEL
750 kcmil (1)
64904999750-61 CU RHH-RHW-2 RW90 1KV DURATRAY BLACK UL/CSA750 KCMIL 1C 61SCUT TO LENGTH REEL
1000 kcmil (1)
649131991000-61 CU RHH-RHW-2 RW90 1KV DURATRAY BLACK UL/CSA1000 KCMIL 1C 61SCUT TO LENGTH REEL

Application & features

Suitable for installation in Cable Trays, Underground Duct Banks - As per CE Code limitations. Standard colour is black. Some sizes may be availabe in white, red, blue, yellow, brown, orange or grey. Green Duraground™ also available.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • CSA C22.2 No. 38 Thermoset-insulated wires and cables
  • CSA C22.2 No.230 Tray Cables - Rated TC-ER (1/0 AWG and Larger)
  • CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
  • CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
  • CSA SUN RES - for Sunlight Resistant rating
  • CSA ST1 Smoke Test - marked FT4-ST1 (1/0 and Larger)
  • Oil Res I & Sun Res - AWG 8 & Larger