DistributorSouthwire

Southwire

CU Compressed 8kV NLEPR Insulation 133% IL CPE-TP Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46272

Type MV-105 Single Conductor Copper, 140 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Thermoplastic Chlorinated Polyethylene (CPE-TP) Jacket, Dual Rated UL/CSA. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (6) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)Conduit Size (in)(cm)
2/0 AWG2/0 AWG19190.4051.030.7241.841403.560.7841.99802.030.9642.4579411821064482.6211.529.213.07.62 64691799
4/0 AWG4/0 AWG19190.5121.300.8162.071403.560.8762.23802.031.0562.68108616161692767.4812.632.003.07.62 58428599
250 KCMIL250 KCMIL37370.5581.420.8842.251403.560.9442.40802.031.1242.85124318502000907.1813.434.043.58.89 66849799
350 KCMIL350 KCMIL37370.6611.680.9672.461403.561.0272.61802.031.2073.071597237728001270.0614.536.833.58.89 64691599
500 KCMIL500 KCMIL37370.7892.001.0922.771403.561.1522.93802.031.3323.382127316540001814.3715.940.394.010.16 55520499
750 KCMIL750 KCMIL61610.9682.461.3043.311403.561.3643.46802.031.5443.923019449360002721.5518.546.994.511.43 56821199
2/0 AWG2/0 AWG0.0810.120.1020.150.0300.040.0420.060.404 + j0.3660.404 + j0.3660.041 + j0.0360.041 + j0.03624562456230230245245300300335335 64691799
4/0 AWG4/0 AWG0.0510.080.0650.100.0250.040.0390.060.405 + j0.2790.405 + j0.2790.066 + j0.0440.066 + j0.04427882788295295315315400400445445 58428599
250 KCMIL250 KCMIL0.0430.060.0560.080.0240.040.0380.060.405 + j0.3670.405 + j0.3670.041 + j0.0360.041 + j0.03629552955325325345345445445495495 66849799
350 KCMIL350 KCMIL0.0310.050.0410.060.0200.030.0360.050.406 + j0.2780.406 + j0.2780.065 + j0.0420.065 + j0.04232743274390390415415550550610610 64691599
500 KCMIL500 KCMIL0.0220.030.0300.040.0180.030.0340.050.406 + j0.3030.406 + j0.3030.056 + j0.0420.056 + j0.04236713671465465500500685685765765 55520499
750 KCMIL750 KCMIL0.0140.020.0230.030.0150.020.0320.050.406 + j0.3030.406 + j0.3030.056 + j0.0420.056 + j0.04242574257565565610610885885990990 56821199

Part numbers in this family (6)

By size:
Southwire #DescriptionConstructionPackaging
646917992/0-19 CU 140 MILS NL-EPR 8KV 133% T/S BLACK CPE-TP UL2/0 AWG 1C 19SCUT TO LENGTH REEL
584285994/0-19 CU 140 MILS NL-EPR 8KV 133% T/S BLACK CPE-TP UL4/0 AWG 1C 19SCUT TO LENGTH REEL
66849799250-37 CU 140 MILS NL-EPR 8KV 133% T/S BLACK CPE-TP UL250 KCMIL 1C 37SCUT TO LENGTH REEL
64691599350-37 CU 140 MILS NL-EPR 8KV 133% T/S BLACK CPE-TP UL350 KCMIL 1C 37SCUT TO LENGTH REEL
55520499500-37 CU 140 MILS NL-EPR 8KV 133% T/S BLACK CPE-TP UL500 KCMIL 1C 37SCUT TO LENGTH REEL
56821199750-61 CU 140 MILS NL-EPR 8KV 133% T/S BLACK CPE-TP UL750 KCMIL 1C 61SCUT TO LENGTH REEL

Application & features

Southwire’s 8KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial when installed with a grounding conductor in close proximity that conforms to NEC section 311.36 and 250.4(A)(5), and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -25°C for cold bend and cold impact and marked with "LTDD" when CSA listed or dual UL/CSA listed. Rated for 1000 lbs./FT maximum sidewall pressure. CT rated 1/0 and larger.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • CSA C22.2 No.230 Tray Cables - Rated TC
  • CSA C22.2 No. 2556 / UL 2556 Cable Test Methods
  • CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661