CU Compressed 5/8kV TRXLPE Insulation 133/100% IL PVC Jacket. MV 105 - Sunlight Resistant - For Direct Burial
- Southwire #
- SPEC46206
Type MV-105 Three Conductor Copper, 115 Mils Tree Retardant Cross Linked Polyethylene (TRXLPE) 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Jacket.. Silicone Free
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (9) ↓Available sizes & constructions
| Cond. Size | Cond. Strands | Diameter Over Conductor (in)(cm) | Diameter Over Insulation (in)(cm) | Insulation Thickness (mils)(mm) | Diameter Over Shield (in)(cm) | Ground Size | Jacket Thickness (mils)(mm) | Approx. OD (inches)(cm) | Approx. Weight (lbs/1000')(kgs/km) | Max Pull Tension (lbs)(kg) | Min. Bend Radius (in)(cm) | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 AWG2 AWG | 77 | 0.2820.72 | 0.5451.38 | 1152.92 | 0.6051.54 | 1x61x6 | 802.03 | 1.5383.91 | 15452299 | 1592722.12 | 10.727.18 | 67341499 |
| 1 AWG1 AWG | 1919 | 0.3220.82 | 0.5901.50 | 1152.92 | 0.6501.65 | 1x41x4 | 802.03 | 1.6224.12 | 18222711 | 2008910.81 | 11.328.70 | 67341399 |
| 1/0 AWG1/0 AWG | 1919 | 0.3610.92 | 0.6301.60 | 1152.92 | 0.6901.75 | 1x41x4 | 1102.79 | 1.7684.49 | 22053281 | 25341149.40 | 12.331.24 | 67341299 |
| 2/0 AWG2/0 AWG | 1919 | 0.4051.03 | 0.6741.71 | 1152.92 | 0.7341.86 | 1x41x4 | 1102.79 | 1.8634.73 | 25423783 | 31941448.77 | 13.033.02 | 67341199 |
| 3/0 AWG3/0 AWG | 1919 | 0.4561.16 | 0.7241.84 | 1152.92 | 0.7841.99 | 1x31x3 | 1102.79 | 1.9715.01 | 29984462 | 40271826.61 | 13.734.80 | 67341099 |
| 4/0 AWG4/0 AWG | 1919 | 0.5121.30 | 0.7661.95 | 1152.92 | 0.8262.10 | 1x31x3 | 1102.79 | 2.0625.24 | 34945200 | 50782303.34 | 14.436.58 | 67340999 |
| 250 KCMIL250 KCMIL | 3737 | 0.5581.42 | 0.8182.08 | 1152.92 | 0.8782.23 | 1x31x3 | 1102.79 | 2.1745.52 | 39785920 | 60002721.55 | 15.238.61 | 67340899 |
| 350 KCMIL350 KCMIL | 3737 | 0.6611.68 | 0.9172.33 | 1152.92 | 0.9772.48 | 1x21x2 | 1102.79 | 2.3886.07 | 51157612 | 84003810.17 | 16.742.42 | 67340799 |
| 500 KCMIL500 KCMIL | 3737 | 0.7892.00 | 1.0422.65 | 1152.92 | 1.1022.80 | 1x11x1 | 1102.79 | 2.6586.75 | 684810191 | 120005443.10 | 18.647.24 | 67336499 |
| 2 AWG2 AWG | 0.1620.24 | 0.2040.30 | 0.0450.07 | 0.0400.06 | 0.499 + j0.4040.499 + j0.404 | 0.133 + j0.0450.133 + j0.045 | 19201920 | 135135 | 145145 | 140140 | 154154 | 67341499 |
| 1 AWG1 AWG | 0.1280.19 | 0.1620.24 | 0.0410.06 | 0.0390.06 | 0.499 + j0.4040.499 + j0.404 | 0.133 + j0.0450.133 + j0.045 | 20442044 | 155155 | 165165 | 160160 | 180180 | 67341399 |
| 1/0 AWG1/0 AWG | 0.1020.15 | 0.1280.19 | 0.0370.06 | 0.0370.06 | 0.499 + j0.4040.499 + j0.404 | 0.133 + j0.0450.133 + j0.045 | 21652165 | 175175 | 190190 | 185185 | 205205 | 67341299 |
| 2/0 AWG2/0 AWG | 0.0810.12 | 0.1020.15 | 0.0340.05 | 0.0360.05 | 0.499 + j0.4290.499 + j0.429 | 0.128 + j0.0440.128 + j0.044 | 23022302 | 200200 | 220220 | 215215 | 240240 | 67341199 |
| 3/0 AWG3/0 AWG | 0.0640.10 | 0.0810.12 | 0.0310.05 | 0.0350.05 | 0.499 + j0.4290.499 + j0.429 | 0.128 + j0.0440.128 + j0.044 | 24592459 | 230230 | 250250 | 250250 | 280280 | 67341099 |
| 4/0 AWG4/0 AWG | 0.0510.08 | 0.0650.10 | 0.0280.04 | 0.0340.05 | 0.499 + j0.4290.499 + j0.429 | 0.128 + j0.0440.128 + j0.044 | 26332633 | 265265 | 280280 | 285285 | 320320 | 67340999 |
| 250 KCMIL250 KCMIL | 0.0430.06 | 0.0560.08 | 0.0270.04 | 0.0330.05 | 0.499 + j0.4290.499 + j0.429 | 0.128 + j0.0440.128 + j0.044 | 28002800 | 290290 | 315315 | 320320 | 355355 | 67340899 |
| 350 KCMIL350 KCMIL | 0.0310.05 | 0.0410.06 | 0.0230.03 | 0.0320.05 | 0.499 + j0.4290.499 + j0.429 | 0.128 + j0.0440.128 + j0.044 | 31203120 | 355355 | 380380 | 395395 | 440440 | 67340799 |
| 500 KCMIL500 KCMIL | 0.0220.03 | 0.0300.04 | 0.0200.03 | 0.0300.04 | 0.499 + j0.4290.499 + j0.429 | 0.128 + j0.0440.128 + j0.044 | 35163516 | 430430 | 460460 | 485485 | 545545 | 67336499 |
Part numbers in this family (9)
| Southwire # | Description | Construction | Conductor Color | Packaging | |
|---|---|---|---|---|---|
| 67341499 | 2-7 3/C CU 115 MILS TR-XLP 5KV 133%/8KV 100% T/S 1X6 CU GW BLACK PVC UL | 2 AWG 3C 7 STR | BLACK-/BLACK-/BLACK-/- | CUT TO LENGTH REEL | |
| 67341399 | 1-19 3/C CU 115 MILS TR-XLP 5KV 133%/8KV 100% T/S 1X4 CU GW BLACK PVC UL | 1 AWG 3C 19 STR | BLACK-/BLACK-/BLACK-/- | CUT TO LENGTH REEL | |
| 67341299 | 1/0-19 3/C CU 115 MILS TR-XLP 5KV 133%/8KV 100% T/S 1X4 CU GW BLACK PVCUL 0 FT | 1/0 AWG 3C 19 STR | BLACK-/BLACK-/BLACK-/- | CUT TO LENGTH REEL | |
| 67341199 | 2/0-19 3/C CU 115 MILS TR-XLP 5KV 133%/8KV 100% T/S 1X4 CU GW BLACK PVCUL | 2/0 AWG 3C 19 STR | BLACK-/BLACK-/BLACK-/- | CUT TO LENGTH REEL | |
| 67341099 | 3/0-19 3/C CU 115 MILS TR-XLP 5KV 133%/8KV 100% T/S 1X3 CU GW BLACK PVCUL | 3/0 AWG 3C 19 STR | BLACK-/BLACK-/BLACK-/- | CUT TO LENGTH REEL | |
| 67340999 | 4/0-19 3/C CU 115 MILS TR-XLP 5KV 133%/8KV 100% T/S 1X3 CU GW BLACK PVCUL | 4/0 AWG 3C 19 STR | BLACK-/BLACK-/BLACK-/- | CUT TO LENGTH REEL | |
| 67340899 | 250-37 3/C CU 115 MILS TR-XLP 5KV 133%/8KV 100% T/S 1X3 CU GW BLACK PVCUL | 250 KCMIL 3C 37S | BLACK-/BLACK-/BLACK-/- | CUT TO LENGTH REEL | |
| 67340799 | 350-37 3/C CU 115 MILS TR-XLP 5KV 133%/8KV 100% T/S 1X2 CU GW BLACK PVCUL | 350 KCMIL 3C 37 STR | BLACK-/BLACK-/BLACK-/- | CUT TO LENGTH REEL | |
| 67336499 | 500-37 3/C CU 115 MILS TR-XLP 5KV 133%/8KV 100% T/S 1X1 CU GW BLACK PVCUL | 500 KCMIL 3C 37S | BLACK-/BLACK-/BLACK-/- | CUT TO LENGTH REEL |
Application & features
Southwire’s 5KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -40°C for cold bend and cold impact and marked with "LTGG" when CSA listed or dual UL/CSA listed. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs./FT maximum sidewall pressure.
Standards & references
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
- UL 1072 Medium-Voltage Power Cables
- ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
- ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
- AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
- Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661