DistributorSouthwire

Southwire

CU Compressed 5/8kV NLEPR Insulation 133/100% IL PVC Jacket. MV 105 - UL Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46202

Type MV-105 Three Conductor Copper, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 5kV 133% / 8kV 100% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Jacket, Dual Rated UL/CSA. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (13) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Ground SizeJacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
2 AWG2 AWG770.2820.720.5451.381152.920.6051.541x61x6802.031.5183.86156123231592722.1210.626.92 95629277
1/0 AWG1/0 AWG19190.3610.920.6301.601152.920.6901.751x41x41102.791.7624.482220330425341149.4012.331.24 95630099
2/0 AWG2/0 AWG19190.4051.030.6741.711152.920.7341.861x41x41102.791.8574.722570382531941448.7712.932.77 95837199
3/0 AWG3/0 AWG19190.4561.160.7241.841152.920.7841.991x31x31102.791.9654.992953439540271826.6113.734.80 55817199
4/0 AWG4/0 AWG19190.5121.300.7661.951152.920.8262.101x31x31102.792.0565.223527524950782303.3414.336.32 95745677
250 KCMIL250 KCMIL37370.5581.420.8342.121152.920.8942.271x21x21102.792.2095.614060604260002721.5515.439.12 95838699
350 KCMIL350 KCMIL37370.6611.680.9172.331152.920.9772.481x21x21102.792.3886.075197773484003810.1716.742.42 95517977
500 KCMIL500 KCMIL37370.7892.001.0422.651152.921.1022.801x11x11102.792.6586.75694810340120005443.1018.647.24 95839777
750 KCMIL750 KCMIL61610.9682.461.2543.191152.921.3143.341x1/01x1/01353.433.1668.04997214840180008164.6622.156.13 55749699
2 AWG2 AWG0.1620.240.2040.300.0340.050.0400.060.355 + j0.2470.355 + j0.2470.023 + j0.0330.023 + j0.03319201920135135145145140140154154 95629277
1/0 AWG1/0 AWG0.1020.150.1280.190.0280.040.0370.060.355 + j0.2470.355 + j0.2470.023 + j0.0330.023 + j0.03321652165175175190190185185205205 95630099
2/0 AWG2/0 AWG0.0810.120.1020.150.0260.040.0360.050.355 + j0.2470.355 + j0.2470.023 + j0.0330.023 + j0.03323022302200200220220215215240240 95837199
3/0 AWG3/0 AWG0.0640.100.0810.120.0240.040.0350.050.324 + j0.1990.324 + j0.1990.019 + j0.0340.019 + j0.03424592459230230250250250250280280 55817199
4/0 AWG4/0 AWG0.0510.080.0650.100.0210.030.0340.050.355 + j0.2470.355 + j0.2470.023 + j0.0330.023 + j0.03326332633265265280280285285320320 95745677
250 KCMIL250 KCMIL0.0430.060.0560.080.0200.030.0330.050.355 + j0.2470.355 + j0.2470.023 + j0.0330.023 + j0.03328002800290290315315320320355355 95838699
350 KCMIL350 KCMIL0.0310.050.0410.060.0180.030.0320.050.353 + j0.2480.353 + j0.2480.024 + j0.0360.024 + j0.03631203120355355380380395395440440 95517977
500 KCMIL500 KCMIL0.0220.030.0300.040.0150.020.0300.040.356 + j0.2420.356 + j0.2420.031 + j0.0390.031 + j0.03935163516430430460460485485545545 95839777
750 KCMIL750 KCMIL0.0140.020.0230.030.0130.020.0290.040.324 + j0.1990.324 + j0.1990.019 + j0.0340.019 + j0.03441024102530530570570615615685685 55749699

Part numbers in this family (13)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
2 AWG (2)
956292772-7 3/C CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S 1X6 CU GW BLACK PVC UL/CSA 0 FT2 AWG 3C 7 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
956292992-7 3/C CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S 1X6 CU GW BLACK PVC UL/CSA 0 FT2 AWG 3C 7 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
1/0 AWG (1)
956300991/0-19 3/C CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S 1X4 CU GW BLACK PVCUL/CSA 0 FT1/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
2/0 AWG (1)
958371992/0-19 3/C CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S 1X4 CU GW BLACK PVCUL/CSA 0 FT2/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
3/0 AWG (1)
558171993/0-19 3/C CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S 1X3 CU GW BLACK PVCUL/CSA3/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
4/0 AWG (2)
957456774/0-19 3/C CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S 1X3 CU GW BLACK PVCUL/CSA E5G04/0C03G 0 FT4/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
957456994/0-19 3/C CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S 1X3 CU GW BLACK PVCUL/CSA E5G04/0C03G4/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
250 kcmil (1)
95838699250-37 3/C CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S 1X2 CU GW BLACK PVCUL/CSA250 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
350 kcmil (2)
95517977350-37 3/C CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S 1X2 CU GW BLACK PVCUL/CSA 0 FT350 KCMIL 3C 37 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
95517999350-37 3/C CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S 1X2 CU GW BLACK PVCUL/CSA350 KCMIL 3C 37 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
500 kcmil (2)
95839777500-37 3/C CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S 1X1 CU GW BLACK PVCUL/CSA 0 FT500 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
95839799500-37 3/C CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S 1X1 CU GW BLACK PVCUL/CSA500 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
750 kcmil (1)
55749699750-61 3/C CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S 1X1/0 CU GW BLACK PVC UL/CSA750 KCMIL 3C 61SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL

Application & features

Southwire’s 5kV / 8kV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -40°C for cold bend and cold impact and marked with "LTGG" when CSA listed. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502. Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • ASTM B496 Compact Round Concentric-lay-standard copper
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations
  • CSA C22.2 No. 2556 / UL 2556 Cable Test Methods
  • CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
  • ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661