DistributorSouthwire

Southwire

CU Compressed 5/8kV NLEPR Insulation 133/100% IL CPE-TP Jacket. MV 105 - UL Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46203

Type MV-105 Three Conductor Copper, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Thermoplastic Chlorinated Polyethylene (CPE-TP) Jacket, Dual Rated UL/CSA. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (6) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Ground SizeJacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
2 AWG2 AWG770.2820.720.5451.381152.920.6051.541x61x6802.031.5183.86156723321592722.1210.626.92 55234599
2/0 AWG2/0 AWG19190.4051.030.6741.711152.920.7341.861x41x41102.791.8574.722583384431941448.7712.932.77 55184899
4/0 AWG4/0 AWG19190.5121.300.7661.951152.920.8262.101x31x31102.792.0365.173496520350782303.3414.236.07 56103899
350 KCMIL350 KCMIL37370.6611.680.9172.331152.920.9772.481x21x21102.792.3886.075208775084003810.1716.742.42 56045099
500 KCMIL500 KCMIL37370.7892.001.0422.651152.921.1022.801x11x11102.792.6886.83702410453120005443.1018.847.75 56123099
750 KCMIL750 KCMIL61610.9682.461.2543.191152.921.3143.341x1/01x1/01353.433.1608.03997314841180008164.6622.156.13 56044999
2 AWG2 AWG0.1620.240.2040.300.0340.050.0400.060.390 + j0.3400.390 + j0.3400.030 + j0.0330.030 + j0.03319201920135135145145140140154154 55234599
2/0 AWG2/0 AWG0.0810.120.1020.150.0260.040.0360.050.392 + j0.2510.392 + j0.2510.066 + j0.0470.066 + j0.04723022302200200220220215215240240 55184899
4/0 AWG4/0 AWG0.0510.080.0650.100.0210.030.0340.050.392 + j0.3400.392 + j0.3400.030 + j0.0310.030 + j0.03126332633265265280280285285320320 56103899
350 KCMIL350 KCMIL0.0310.050.0410.060.0180.030.0320.050.392 + j0.3400.392 + j0.3400.030 + j0.0310.030 + j0.03131203120355355380380395395440440 56045099
500 KCMIL500 KCMIL0.0220.030.0300.040.0150.020.0300.040.392 + j0.3400.392 + j0.3400.030 + j0.0310.030 + j0.03135163516430430460460485485545545 56123099
750 KCMIL750 KCMIL0.0140.020.0230.030.0130.020.0290.040.392 + j0.3400.392 + j0.3400.030 + j0.0310.030 + j0.03141024102530530570570615615685685 56044999

Part numbers in this family (6)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
552345992-7 3/C CU 115 MILS NL-EPR T/S GW 5KV 133%/8KV 100% BLACK CPE JACKET2 AWG 3C 7 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
551848992/0-19 3/C CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S 1X4 CU GW BLACK CPE-TP UL2/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
561038994/0-19 3/C CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S 1X3 CU GW BLACK CPE-TP UL4/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
56045099350-37 3/C CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S 1X2 CU GW BLACK CPE-TP UL E5G350C03G-093350 KCMIL 3C 37 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
56123099500-37 3/C CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S 1X1 CU GW BLACK CPE-TP UL500 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
56044999750-61 3/C CU 115 MILS NL-EPR 5KV 133%/8KV 100% T/S 1X1/0 CU GW BLACK CPE-TP UL750 KCMIL 3C 61SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL

Application & features

Southwire’s 5KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -40°C for cold bend 1/0 and larger. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502. Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • CSA C22.2 No. 2556 / UL 2556 Cable Test Methods
  • CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
  • ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661