DistributorSouthwire

Southwire

CU Compressed 5/8kV NLEPR Insulation 133/100% IL AIA LSZH-TP Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46258

Type MV-105 Three Conductor Copper, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Aluminum Interlocked Armor (AIA), Thermoplastic SOLONON® Low Smoke Zero Halogen (LSZH-TP) Jacket. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (5) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Ground SizeDiameter Over Armor (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
1/0 AWG1/0 AWG19190.3620.920.6301.601152.920.6901.751x41x41.8624.73601.521.9885.052651394525341149.4013.935.31 13778699
4/0 AWG4/0 AWG19190.5121.300.7661.951152.920.8262.101x31x32.1605.49601.522.2865.813736556050782303.3416.040.64 59265799
250 KCMIL250 KCMIL37370.5581.420.8182.081152.920.8782.231x21x22.2685.76802.032.4326.184345646660002721.5517.043.18 56493699
350 KCMIL350 KCMIL37370.6611.680.9172.331152.920.9772.481x21x22.4816.30802.032.6476.725516820984003810.1718.546.99 56493599
500 KCMIL500 KCMIL37370.7892.001.0422.651152.921.1022.801x11x12.7516.99802.032.9157.40729110850120005443.1020.451.82 56493499
1/0 AWG1/0 AWG0.1020.150.1280.190.0280.040.0370.060.410 + j0.3820.410 + j0.3820.041 + j0.0320.041 + j0.03221652165175175190190185185205205 13778699
4/0 AWG4/0 AWG0.0510.080.0650.100.0210.030.0340.050.411 + j0.3570.411 + j0.3570.046 + j0.0310.046 + j0.03126332633265265280280285285320320 59265799
250 KCMIL250 KCMIL0.0430.060.0560.080.0200.030.0330.050.412 + j0.3320.412 + j0.3320.057 + j0.0430.057 + j0.04328002800290290315315320320355355 56493699
350 KCMIL350 KCMIL0.0310.050.0410.060.0180.030.0320.050.412 + j0.3320.412 + j0.3320.057 + j0.0430.057 + j0.04331203120355355380380395395440440 56493599
500 KCMIL500 KCMIL0.0220.030.0300.040.0150.020.0300.040.413 + j0.3060.413 + j0.3060.066 + j0.0470.066 + j0.04735163516430430460460485485545545 56493499

Part numbers in this family (5)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
137786991/0-19 3/C CU 115 NL-EPR T/S 1X4 CU GW AIA YELLOW SOLONON-TP JACKET 5KV133%/8KV 100% UL1/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
592657994/0-19 3/C CU 115 NL-EPR T/S 1X3 CU GW AIA YELLOW SOLONON-TP JACKET 5KV133%/8KV 100% UL4/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
56493699250-37 3/C CU 115 NL-EPR T/S 1X2 CU GW AIA YELLOW SOLONON-TP JACKET 5KV133%/8KV 100% UL250 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
56493599350-37 3/C CU 115 NL-EPR T/S 1X2 CU GW AIA YELLOW SOLONON-TP JACKET 5KV133%/8KV 100% UL350 KCMIL 3C 37 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
56493499500-37 3/C CU 115 NL-EPR T/S 1X1 CU GW AIA YELLOW SOLONON-TP JACKET 5KV133%/8KV 100% UL500 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL

Application & features

Southwire’s 5KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -25°C for cold bend. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 FT4-ST1 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661