CU Compressed 5/8kV NLEPR Insulation 133/100% IL AIA LSZH-TP Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
- Southwire #
- SPEC46258
Type MV-105 Three Conductor Copper, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Aluminum Interlocked Armor (AIA), Thermoplastic SOLONON® Low Smoke Zero Halogen (LSZH-TP) Jacket. Silicone Free
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (5) ↓Available sizes & constructions
| Cond. Size | Cond. Strands | Diameter Over Conductor (in)(cm) | Diameter Over Insulation (in)(cm) | Insulation Thickness (mils)(mm) | Diameter Over Shield (in)(cm) | Ground Size | Diameter Over Armor (in)(cm) | Jacket Thickness (mils)(mm) | Approx. OD (inches)(cm) | Approx. Weight (lbs/1000')(kgs/km) | Max Pull Tension (lbs)(kg) | Min. Bend Radius (in)(cm) | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1/0 AWG1/0 AWG | 1919 | 0.3620.92 | 0.6301.60 | 1152.92 | 0.6901.75 | 1x41x4 | 1.8624.73 | 601.52 | 1.9885.05 | 26513945 | 25341149.40 | 13.935.31 | 13778699 |
| 4/0 AWG4/0 AWG | 1919 | 0.5121.30 | 0.7661.95 | 1152.92 | 0.8262.10 | 1x31x3 | 2.1605.49 | 601.52 | 2.2865.81 | 37365560 | 50782303.34 | 16.040.64 | 59265799 |
| 250 KCMIL250 KCMIL | 3737 | 0.5581.42 | 0.8182.08 | 1152.92 | 0.8782.23 | 1x21x2 | 2.2685.76 | 802.03 | 2.4326.18 | 43456466 | 60002721.55 | 17.043.18 | 56493699 |
| 350 KCMIL350 KCMIL | 3737 | 0.6611.68 | 0.9172.33 | 1152.92 | 0.9772.48 | 1x21x2 | 2.4816.30 | 802.03 | 2.6476.72 | 55168209 | 84003810.17 | 18.546.99 | 56493599 |
| 500 KCMIL500 KCMIL | 3737 | 0.7892.00 | 1.0422.65 | 1152.92 | 1.1022.80 | 1x11x1 | 2.7516.99 | 802.03 | 2.9157.40 | 729110850 | 120005443.10 | 20.451.82 | 56493499 |
| 1/0 AWG1/0 AWG | 0.1020.15 | 0.1280.19 | 0.0280.04 | 0.0370.06 | 0.410 + j0.3820.410 + j0.382 | 0.041 + j0.0320.041 + j0.032 | 21652165 | 175175 | 190190 | 185185 | 205205 | 13778699 | |
| 4/0 AWG4/0 AWG | 0.0510.08 | 0.0650.10 | 0.0210.03 | 0.0340.05 | 0.411 + j0.3570.411 + j0.357 | 0.046 + j0.0310.046 + j0.031 | 26332633 | 265265 | 280280 | 285285 | 320320 | 59265799 | |
| 250 KCMIL250 KCMIL | 0.0430.06 | 0.0560.08 | 0.0200.03 | 0.0330.05 | 0.412 + j0.3320.412 + j0.332 | 0.057 + j0.0430.057 + j0.043 | 28002800 | 290290 | 315315 | 320320 | 355355 | 56493699 | |
| 350 KCMIL350 KCMIL | 0.0310.05 | 0.0410.06 | 0.0180.03 | 0.0320.05 | 0.412 + j0.3320.412 + j0.332 | 0.057 + j0.0430.057 + j0.043 | 31203120 | 355355 | 380380 | 395395 | 440440 | 56493599 | |
| 500 KCMIL500 KCMIL | 0.0220.03 | 0.0300.04 | 0.0150.02 | 0.0300.04 | 0.413 + j0.3060.413 + j0.306 | 0.066 + j0.0470.066 + j0.047 | 35163516 | 430430 | 460460 | 485485 | 545545 | 56493499 |
Part numbers in this family (5)
| Southwire # | Description | Construction | Conductor Color | Packaging | |
|---|---|---|---|---|---|
| 13778699 | 1/0-19 3/C CU 115 NL-EPR T/S 1X4 CU GW AIA YELLOW SOLONON-TP JACKET 5KV133%/8KV 100% UL | 1/0 AWG 3C 19 STR | BLACK-/BLACK-/BLACK-/- | CUT TO LENGTH REEL | |
| 59265799 | 4/0-19 3/C CU 115 NL-EPR T/S 1X3 CU GW AIA YELLOW SOLONON-TP JACKET 5KV133%/8KV 100% UL | 4/0 AWG 3C 19 STR | BLACK-/BLACK-/BLACK-/- | CUT TO LENGTH REEL | |
| 56493699 | 250-37 3/C CU 115 NL-EPR T/S 1X2 CU GW AIA YELLOW SOLONON-TP JACKET 5KV133%/8KV 100% UL | 250 KCMIL 3C 37S | BLACK-/BLACK-/BLACK-/- | CUT TO LENGTH REEL | |
| 56493599 | 350-37 3/C CU 115 NL-EPR T/S 1X2 CU GW AIA YELLOW SOLONON-TP JACKET 5KV133%/8KV 100% UL | 350 KCMIL 3C 37 STR | BLACK-/BLACK-/BLACK-/- | CUT TO LENGTH REEL | |
| 56493499 | 500-37 3/C CU 115 NL-EPR T/S 1X1 CU GW AIA YELLOW SOLONON-TP JACKET 5KV133%/8KV 100% UL | 500 KCMIL 3C 37S | BLACK-/BLACK-/BLACK-/- | CUT TO LENGTH REEL |
Application & features
Southwire’s 5KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -25°C for cold bend. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs./FT maximum sidewall pressure.
Standards & references
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
- UL 1072 Medium-Voltage Power Cables
- UL 1685 FT4-ST1 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
- ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
- ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
- ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
- AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
- Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661