DistributorSouthwire

Southwire

CU Compressed 5/8kV NLEPR Insulation 133/100% IL AIA CPE-TP Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46259

Type MV-105 Three Conductor Copper, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Aluminum Interlocked Armor (AIA), Thermoplastic Chlorinated Polyethylene (CPE-TP) Jacket. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (5) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Ground SizeDiameter Over Armor (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
2 AWG2 AWG770.2820.720.5451.381152.920.6051.541x61x61.6804.27651.651.8124.60182227111592722.1212.632.00 58324699
2/0 AWG2/0 AWG19190.4051.030.6731.711152.920.7331.861x41x41.9484.95601.522.0685.252645393631941448.7714.436.58 45701099
4/0 AWG4/0 AWG19190.5121.300.7661.951152.920.8262.101x31x32.1555.47651.652.2875.813726554550782303.3416.040.64 57665199
250 KCMIL250 KCMIL37370.5581.420.8182.081152.920.8782.231x21x22.2785.79802.032.4426.204330644460002721.5517.043.18 57753199
500 KCMIL500 KCMIL37370.7892.001.0422.651152.921.1022.801x11x12.7516.99802.032.9157.40767111416120005443.1020.451.82 67757799
2 AWG2 AWG0.1620.240.2040.300.0340.050.0400.060.487 + j0.5110.487 + j0.5110.128 + j0.0420.128 + j0.04219201920135135145145140140154154 58324699
2/0 AWG2/0 AWG0.0810.120.1020.150.0260.040.0360.050.489 + j0.3510.489 + j0.3510.128 + j0.0490.128 + j0.04923022302200200220220215215240240 45701099
4/0 AWG4/0 AWG0.0510.080.0650.100.0210.030.0340.050.489 + j0.3650.489 + j0.3650.129 + j0.0510.129 + j0.05126332633265265280280285285320320 57665199
250 KCMIL250 KCMIL0.0430.060.0560.080.0200.030.0330.050.489 + j0.3650.489 + j0.3650.129 + j0.0510.129 + j0.05128002800290290315315320320355355 57753199
500 KCMIL500 KCMIL0.0220.030.0300.040.0150.020.0300.040.491 + j0.3450.491 + j0.3450.134 + j0.0490.134 + j0.04935163516430430460460485485545545 67757799

Part numbers in this family (5)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
583246992-7 3/C CU 115 NL-EPR T/S 1X6 CU GW AIA YELLOW CPE-TP JACKET 5KV 133%/8KV 100% UL2 AWG 3C 7 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
457010992/0-19 3/C CU 115 NL-EPR T/S 1X4 CU GW AIA BLACK CPE-TP JACKET 5KV 133%/8KV 100% UL2/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
576651994/0-19 3/C CU 115 NL-EPR T/S 1X3 CU GW AIA BLACK CPE-TP JACKET 5KV 133%/8KV 100% UL4/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
57753199250-37 3/C CU 115 NL-EPR T/S 1X2 CU GW AIA BLACK CPE-TP JACKET 5KV 133%/8KV 100% UL250 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
67757799500-37 3/C CU 115 NL-EPR T/S 1X1 CU GW AIA YELLOW CPE-TP JACKET 5KV 133%/8KV 100% UL500 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL

Application & features

Southwire’s 5KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -25°C for cold bend. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661