DistributorSouthwire

Southwire

CU Compressed 35kV NLEPR Insulation 133% IL Black PVC Jacket. MV 105 - UL Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46802

Type MV-105 Three Conductor Copper, 420 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Jacket, Dual Rated UL/CSA. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (5) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Ground SizeJacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
1/0 AWG1/0 AWG19190.3610.921.2403.1542010.671.3003.301x1/01x1/01353.433.1257.944808715525341149.4021.855.37 58214799
2/0 AWG2/0 AWG19190.4051.031.2843.2642010.671.3443.411x41x41353.433.2208.185032748831941448.7722.557.15 45910799
4/0 AWG4/0 AWG19190.5121.301.3903.5342010.671.4503.683x33x31353.433.4608.796527971350782303.3424.261.47 59785399
750 KCMIL750 KCMIL61610.9682.461.8644.7342010.671.9244.891x1/01x1/01353.434.48411.391252218635100004535.9231.479.76 45837099
1/0 AWG1/0 AWG0.1020.150.1280.190.0640.100.0510.080.436 + j0.4250.436 + j0.4250.065 + j0.0350.065 + j0.03540554055195195210210215215240240 58214799
2/0 AWG2/0 AWG0.0810.120.1020.150.0600.090.0500.070.436 + j0.4250.436 + j0.4250.065 + j0.0350.065 + j0.03541924192220220235235245245275275 45910799
4/0 AWG4/0 AWG0.0510.080.0650.100.0520.080.0460.070.435 + j0.4000.435 + j0.4000.065 + j0.0370.065 + j0.03745234523285285305305325325360360 59785399
750 KCMIL750 KCMIL0.0140.020.0220.030.0290.040.0370.060.321 + j0.1910.321 + j0.1910.024 + j0.0380.024 + j0.03859925992545545585585670670745745 45837099

Part numbers in this family (5)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
1/0 AWG (1)
582147991/0-19 3/C CU 420 MILS NL-EPR 35KV 133% T/S 1X1/0 CU GW RED PVC UL/CSA1/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
2/0 AWG (2)
459107992/0-19 3/C CU 420 MILS NL-EPR 35KV 133% T/S 1X4 CU GW BLACK PVC UL/CSA2/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
578337992/0-19 3/C CU 420 MILS NL-EPR T/S GW 35KV 133% RED PVC JACKET2/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
4/0 AWG (1)
597853994/0-19 3/C CU 420 MILS NL-EPR 35KV 133% T/S 3X3 CU GW BLACK PVC UL/CSA4/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-/-/-CUT TO LENGTH REEL
750 kcmil (1)
45837099750-61 3/C CU 420 MILS NL-EPR 35KV 133% T/S 1X1/0 CU GW BLACK PVC UL/CSA750 KCMIL 3C 61SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL

Application & features

Southwire’s 35KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -40°C for cold bend and cold impact and marked with "LTGG" when CSA listed or dual UL/CSA listed. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • CSA C22.2 No. 2556 / UL 2556 Cable Test Methods
  • CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
  • ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661