DistributorSouthwire

Southwire

CU Compressed 35kV NLEPR Insulation 100% IL ARMOR-X® Orange PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46852

Type MV-105 Three Conductor Copper, 345 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 100% Insulation Level, Tape Shield, Continuous Corrugated Welded Armor - ARMOR-X®, Polyvinyl Chloride (PVC) Jacket. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (2) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Ground SizeDiameter Over Armor (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
1/0 AWG1/0 AWG19190.3610.921.0902.773458.761.1502.921x41x43.0007.62852.163.1708.054703699925341149.4022.156.13 58201199
350 KCMIL350 KCMIL37370.6611.681.3973.553458.761.4573.701x21x24.20110.67952.414.39111.1586291284184003810.1730.777.98 67310299
1/0 AWG1/0 AWG0.1020.150.1280.190.0570.080.0490.070.366 + j0.2420.366 + j0.2420.042 + j0.0430.042 + j0.04335903590195195210210215215240240 58201199
350 KCMIL350 KCMIL0.0310.050.0410.060.0390.060.0400.060.366 + j0.2770.366 + j0.2770.024 + j0.0350.024 + j0.03545454545375375400400435435490490 67310299

Part numbers in this family (2)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
582011991/0-19 3/C CPRESS CU NL-EPR 25% T/S 1X#4 CU GW ARMOR-X MC-HL OR MV-105 35KV 100% RED PVC JACKET1/0 AWG 3C 19 STR1-BLACK/BLACK-/BLACK-/4 AWG BARE GRNDCUT TO LENGTH REEL
67310299350-37 3/C CPRESS CU NL-EPR 25% T/S 1X#2 CU GW ARMOR-X MC-HL OR MV-105 35KV 100% ORANGE PVC JACKET350 KCMIL 3C 37 STR1-BLACK/BLACK-/BLACK-/2 AWG BARE GRNDCUT TO LENGTH REEL

Application & features

Southwire’s 35KV ARMOR-X® are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661