DistributorSouthwire

Southwire

CU Compressed 25kV NLEPR Insulation 133% IL ARMOR-X® Orange PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46654

Type MV-105 Three Conductor Copper, 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Continuous Corrugated Welded Armor - ARMOR-X®, Polyvinyl Chloride (PVC) Jacket. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (2) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Ground SizeDiameter Over Armor (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
2/0 AWG2/0 AWG19190.4051.031.0842.753208.131.1442.911x41x43.0007.62751.913.1588.024619687431941448.7722.055.88 64993899
500 KCMIL500 KCMIL37370.7661.951.4523.693208.131.5123.841x11x13.8509.78902.294.02810.23943514041120005443.1028.271.63 66498599
2/0 AWG2/0 AWG0.0810.120.1020.150.0510.080.0460.070.417 + j0.3160.417 + j0.3160.066 + j0.0410.066 + j0.04135723572220220235235245245275275 64993899
500 KCMIL500 KCMIL0.0220.030.0300.040.0320.050.0370.060.417 + j0.3540.417 + j0.3540.057 + j0.0410.057 + j0.04147864786450450485485535535600600 66498599

Part numbers in this family (2)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
649938992/0-19 3/C CPRESS CU NL-EPR 25% T/S 1X#4 CU GW ARMOR-X MC-HL OR MV-105 25KV 133% ORANGE PVC JACKET2/0 AWG 3C 19 STR1-BLACK/BLACK-/BLACK-/4 AWG BARE GRNDCUT TO LENGTH REEL
66498599500-37 3/C CPRESS CU NL-EPR 25% T/S 1X#1 CU GW ARMOR-X MC-HL OR MV-105 25KV 133% ORANGE PVC JACKET500 KCMIL 3C 37S1-BLACK/BLACK-/BLACK-/1 AWG BARE GRNDCUT TO LENGTH REEL

Application & features

Southwire’s 25KV ARMOR-X® are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • ASTM B496 Compact Round Concentric-lay-standard copper
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661
  • ABS Listed as CWCMC