DistributorSouthwire

Southwire

CU Compressed 2.4kV NLEPR Insulation 100% IL PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46006

Type MV-105 Three Conductor Copper, 90 Mils No Lead Ethylene Propylene Rubber (NL-EPR) Polyvinyl Chloride (PVC) Jacket. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (6) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Ground SizeJacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
2 AWG2 AWG770.2820.720.4951.26902.291 x 61 x 6802.031.2393.15114317011592722.128.621.84 60042999
1/0 AWG1/0 AWG19190.3610.920.5801.47902.291 x 41 x 4802.031.4223.611688251225341149.409.925.15 60041199
4/0 AWG4/0 AWG19190.5121.300.7151.82902.291 x 31 x 31102.791.7744.512997446050782303.3412.431.50 60039599
350 KCMIL350 KCMIL37370.6611.680.8852.25902.291 x 21 x 21102.792.1565.484629688984003810.1715.138.35 60044599
500 KCMIL500 KCMIL37370.7892.001.0152.58902.291 x 11 x 11102.792.4376.1963109390120005443.1017.143.43 60038799
2 AWG2 AWG0.1620.240.2040.300.0350.050.186 + j0.020.186 + j0.020.196 + j0.0290.196 + j0.029135135145145140140154154 60042999
1/0 AWG1/0 AWG0.1020.150.1280.190.0320.050.11 + j0.0170.11 + j0.0170.12 + j0.0260.12 + j0.026175175190190185185205205 60041199
4/0 AWG4/0 AWG0.0510.080.0650.100.0300.040.047 + j0.0150.047 + j0.0150.057 + j0.0230.057 + j0.023265265280280285285320320 60039599
350 KCMIL350 KCMIL0.0310.050.0410.060.0280.040.023 + j0.0130.023 + j0.0130.033 + j0.0220.033 + j0.022355355380380395395440440 60044599
500 KCMIL500 KCMIL0.0220.030.0300.040.0270.040.012 + j0.0120.012 + j0.0120.022 + j0.0210.022 + j0.021430430460460485485545545 60038799

Part numbers in this family (6)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
2 AWG (1)
600429992-7 CU 3C 90 MILS NL-EPR 2400V N/S WET/DRY 1X6 CU GW PVC JACKET2 AWG 3C 7 STRBLACK/NATURAL-/BLACK/NATURAL-/BLACK/NATURAL-/-CUT TO LENGTH REEL
1/0 AWG (1)
600411991/0-19 CU 3C 90 MILS NL-EPR 2400V N/S WET/DRY 1X4 CU GW PVC JACKET1/0 AWG 3C 19 STRBLACK/NATURAL-/BLACK/NATURAL-/BLACK/NATURAL-/-CUT TO LENGTH REEL
4/0 AWG (1)
600395994/0-19 CU 3C 90 MILS NL-EPR 2400V N/S WET/DRY 1X3 CU GW PVC JACKET4/0 AWG 3C 19 STRBLACK/NATURAL-/BLACK/NATURAL-/BLACK/NATURAL-/-CUT TO LENGTH REEL
350 kcmil (2)
60044599350-37 CU 3C 90 MILS NL-EPR 2400V N/S WET/DRY 1X2 CU GW PVC JACKET350 KCMIL 3C 37 STRBLACK/NATURAL-/BLACK/NATURAL-/BLACK/NATURAL-/-CUT TO LENGTH REEL
67927199350-37 CU 3C 90 MILS NL-EPR 2400V N/S WET/DRY 1X1 CU GW PVC JACKET350 KCMIL 3C 37 STRBLACK/NATURAL-/BLACK/NATURAL-/BLACK/NATURAL-/-CUT TO LENGTH REEL
500 kcmil (1)
60038799500-37 CU 3C 90 MILS NL-EPR 2400V N/S WET/DRY 1X1 CU GW PVC JACKET500 KCMIL 3C 37SBLACK/NATURAL-/BLACK/NATURAL-/BLACK/NATURAL-/-CUT TO LENGTH REEL

Application & features

Southwire’s 2.4KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -40°C for cold bend and cold impact and marked with "LTGG" when CSA listed or dual UL/CSA listed. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-96-659 (NEMA WC 71) 2001-5000 V Nonshielded Cables
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661