DistributorSouthwire

Southwire

CU Compressed 15kV NLEPR Insulation 133% IL GSIA Red PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46462

Type MV-105 Three Conductor Copper, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Galvanized Steel Interlocked Armor (GSIA), Polyvinyl Chloride (PVC) Jacket. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (6) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Ground SizeDiameter Over Armor (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
2 AWG2 AWG770.2820.720.7551.922205.590.8152.071x61x62.1225.39651.652.2545.73295143921592722.1215.739.88 61010599
2/0 AWG2/0 AWG19190.4051.030.8842.252205.590.9442.401x11x12.4006.10802.032.5666.524213627031941448.7717.945.47 58197299
250 KCMIL250 KCMIL37370.5581.421.0282.612205.591.0882.761x21x22.9317.44802.033.0977.876317940160002721.5521.654.86 56080199
350 KCMIL350 KCMIL37370.6611.681.1272.862205.591.1873.011x21x22.9257.43802.033.0917.8570561050084003810.1721.654.86 61103899
500 KCMIL500 KCMIL37370.7892.001.2523.182205.591.3123.331x11x13.1958.12902.293.3838.59905913481120005443.1023.659.94 58197399
2 AWG2 AWG0.1620.240.2040.300.0510.080.0470.070.427 + j0.4210.427 + j0.4210.056 + j0.0340.056 + j0.03425712571150150160160165165185185 61010599
2/0 AWG2/0 AWG0.0810.120.1020.150.0400.060.0420.060.527 + j0.5120.527 + j0.5120.162 + j0.0410.162 + j0.04129522952220220235235245245275275 58197299
250 KCMIL250 KCMIL0.0430.060.0560.080.0320.050.0380.060.427 + j0.4210.427 + j0.4210.056 + j0.0340.056 + j0.03434513451310310335335360360400400 56080199
350 KCMIL350 KCMIL0.0310.050.0410.060.0280.040.0360.050.427 + j0.4210.427 + j0.4210.056 + j0.0340.056 + j0.03437703770375375400400435435490490 61103899
500 KCMIL500 KCMIL0.0220.030.0300.040.0250.040.0340.050.427 + j0.4210.427 + j0.4210.056 + j0.0340.056 + j0.03441674167450450485485535535600600 58197399

Part numbers in this family (6)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
2 AWG (1)
610105992-7 3/C CU 220 NL-EPR T/S 1X6 CU GW GSIA RED PVC JACKET 15KV 133% UL2 AWG 3C 7 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
2/0 AWG (1)
581972992/0-19 3/C CU 220 NL-EPR T/S 1X1 CU GW GSIA RED PVC JACKET 15KV 133% UL2/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
250 kcmil (1)
56080199250-37 3/C CU 220 NL-EPR T/S 1X2 CU GW PVC INNER JKT GSIA RED PVC JACKET 15KV 133% UL250 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
350 kcmil (1)
61103899350-37 3/C CU 220 NL-EPR T/S 1X2 CU GW GSIA RED PVC JACKET 15KV 133% UL350 KCMIL 3C 37 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
500 kcmil (2)
58197399500-37 3/C CU 220 NL-EPR T/S 1X1 CU GW GSIA RED PVC JACKET 15KV 133% UL500 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
67099299500-37 3/C CU 220 NL-EPR 1X1/0CU GW GSIA RED PVC JACKET 15KV 133%500 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL

Application & features

Southwire’s 15KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -40°C for cold bend and cold impact and marked with "LTGG" when CSA listed or dual UL/CSA listed. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661