DistributorSouthwire

Southwire

CU Compressed 15kV NLEPR Insulation 133% IL Black PVC Jacket. MV 105 - UL Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46402

Type MV-105 Three Conductor Copper, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Jacket, Dual Rated UL/CSA. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (14) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Ground SizeJacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
2 AWG2 AWG770.2820.720.7551.922205.590.8152.071x61x61102.792.0325.16223633281592722.1214.236.07 95649099
1/0 AWG1/0 AWG19190.3610.920.8402.132205.590.9002.291x41x41102.792.2155.632758410425341149.4015.539.37 95830699
2/0 AWG2/0 AWG19190.4051.030.8842.252205.590.9442.401x41x41102.792.3105.873237481731941448.7716.140.89 55825499
4/0 AWG4/0 AWG19190.5121.300.9762.482205.591.0362.631x31x31102.792.5166.394288638150782303.3417.644.70 95628477
250 KCMIL250 KCMIL37370.5581.421.0282.612205.591.0882.761x21x21102.792.6286.684815716660002721.5518.346.48 55828899
350 KCMIL350 KCMIL37370.6611.681.1472.912205.591.2073.071x1/01x1/01353.432.9357.456288935884003810.1720.552.07 67198999
500 KCMIL500 KCMIL37370.7892.001.2753.242205.591.3353.391x4/01x4/01353.433.2038.14837412462120005443.1022.456.90 57861499
750 KCMIL750 KCMIL61610.9682.461.4643.722205.591.5243.871x1/01x1/01353.433.6209.191104016429180008164.6625.364.26 55831299
2 AWG2 AWG0.1620.240.2040.300.0510.080.0470.070.355 + j0.2470.355 + j0.2470.023 + j0.0330.023 + j0.03325712571150150160160165165185185 95649099
1/0 AWG1/0 AWG0.1020.150.1280.190.0430.060.0430.060.355 + j0.2470.355 + j0.2470.023 + j0.0330.023 + j0.03328162816195195210210215215240240 95830699
2/0 AWG2/0 AWG0.0810.120.1020.150.0400.060.0420.060.324 + j0.1990.324 + j0.1990.019 + j0.0340.019 + j0.03429522952220220235235245245275275 55825499
4/0 AWG4/0 AWG0.0510.080.0650.100.0340.050.0390.060.355 + j0.2470.355 + j0.2470.023 + j0.0330.023 + j0.03332843284285285305305325325360360 95628477
250 KCMIL250 KCMIL0.0430.060.0560.080.0320.050.0380.060.326 + j0.2020.326 + j0.2020.018 + j0.0320.018 + j0.03234513451310310335335360360400400 55828899
350 KCMIL350 KCMIL0.0310.050.0410.060.0280.040.0360.050.529 + j0.4450.529 + j0.4450.162 + j0.0490.162 + j0.04937703770375375400400435435490490 67198999
500 KCMIL500 KCMIL0.0220.030.0300.040.0250.040.0340.050.529 + j0.4450.529 + j0.4450.162 + j0.0490.162 + j0.04941674167450450485485535535600600 57861499
750 KCMIL750 KCMIL0.0140.020.0230.030.0210.030.0320.050.327 + j0.1960.327 + j0.1960.027 + j0.0380.027 + j0.03847524752545545585585670670745745 55831299

Part numbers in this family (14)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
2 AWG (1)
956490992-7 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X6 CU GW BLACK PVC UL/CSA2 AWG 3C 7 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
1/0 AWG (1)
958306991/0-19 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X4 CU GW BLACK PVC UL/CSA1/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
2/0 AWG (1)
558254992/0-19 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X4 CU GW BLACK PVC UL/CSA2/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
4/0 AWG (2)
956284774/0-19 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X3 CU GW BLACK PVC UL/CSA 0 FT4/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
956284994/0-19 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X3 CU GW BLACK PVC UL/CSA4/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
250 kcmil (1)
55828899250-37 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X2 CU GW BLACK PVC UL/CSA250 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
350 kcmil (2)
67198999350-37 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X1/0 CU GW BLACK PVC UL350 KCMIL 3C 37 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
95832299350-37 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X2 CU GW BLACK PVC UL/CSA350 KCMIL 3C 37 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
500 kcmil (4)
57861499500-37 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X4/0 CU GW BLACK PVC UL500 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
95833077500-37 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X1 CU GW BLACK PVC UL/CSA 0 FT500 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
95833099500-37 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X1 CU GW BLACK PVC UL/CSA500 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
65358399500-37 3/C CU 220 MILS NL-EPR 15KV 133% T/S 3X1 CU GW BLACK PVC UL500 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-/-/-CUT TO LENGTH REEL
750 kcmil (2)
55831299750-61 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X1/0 CU GW BLACK PVC UL/CSA750 KCMIL 3C 61SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
65356299750-61 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X1/0 CU GW RED PVC UL750 KCMIL 3C 61SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL

Application & features

Southwire’s 15KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerially supported by a messenger and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -40°C for cold bend and cold impact and marked with "LTGG" when CSA listed or dual UL/CSA listed. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • CSA C22.2 No. 2556 / UL 2556 Cable Test Methods
  • CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
  • ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661