CU Compressed 15kV NLEPR Insulation 133% IL Black LSZH-TS Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46318

Type MV-105 Single Conductor Copper, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Thermoset SOLONON® Low Smoke Zero Halogen (LSZH-TS) Jacket, Dual Rated UL/CSA. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (4) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)Conduit Size (in)(cm)
2/0 AWG2/0 AWG19190.4051.030.8842.252205.590.9442.40802.031.1402.9095614231064482.6213.634.543.58.89 66441999
4/0 AWG4/0 AWG19190.5121.300.9902.512205.591.0502.67802.031.2463.16127118911692767.4814.937.853.58.89 66442299
350 KCMIL350 KCMIL37370.6611.681.1472.912205.591.2073.07802.031.4033.561807268928001270.0616.842.674.010.16 66442599
500 KCMIL500 KCMIL37370.7892.001.2523.182205.591.3123.33802.031.5083.832342348540001814.3718.045.724.511.43 66442899
2/0 AWG2/0 AWG0.0810.120.1020.150.0400.060.0450.070.556 + j0.5530.556 + j0.5530.204 + j0.0440.204 + j0.04443794379230230245245300300335335 66441999
4/0 AWG4/0 AWG0.0510.080.0650.100.0340.050.0420.060.555 + j0.5520.555 + j0.5520.204 + j0.0450.204 + j0.04548714871295295315315400400445445 66442299
350 KCMIL350 KCMIL0.0310.050.0410.060.0280.040.0390.060.555 + j0.5520.555 + j0.5520.204 + j0.0450.204 + j0.04555935593390390415415550550610610 66442599
500 KCMIL500 KCMIL0.0220.030.0300.040.0250.040.0370.060.555 + j0.5520.555 + j0.5520.204 + j0.0450.204 + j0.04561816181465465500500685685765765 66442899

Part numbers in this family (4)

By size:
Southwire #DescriptionConstructionPackaging
664419992/0-19 CU 220 MILS NL-EPR 15KV 133% T/S BLACK SOLONON-TS JACKET CT RATED UL/CSA2/0 AWG 1C 19SCUT TO LENGTH REEL
664422994/0-19 CU 220 MILS NL-EPR 15KV 133% T/S BLACK SOLONON-TS JACKET CT RATED UL/CSA4/0 AWG 1C 19SCUT TO LENGTH REEL
66442599350-37 CU 220 MILS NL-EPR 15KV 133% T/S BLACK SOLONON-TS JACKET CT RATED UL/CSA350 KCMIL 1C 37SCUT TO LENGTH REEL
66442899500-37 CU 220 MILS NL-EPR 15KV 133% T/S BLACK SOLONON-TS JACKET CT RATED UL/CSA500 KCMIL 1C 37SCUT TO LENGTH REEL

Application & features

Southwire’s 15KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial when installed with a grounding conductor in close proximity that conforms to NEC section 311.36 and 250.4(A)(5), and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -40°C for cold bend. ST1 (low smoke) Rated for sizes 1/0 and larger. Rated for 1000 lbs./FT maximum sidewall pressure. Thermoset Solonon® jacket (LSZH-TS or XL LSZH).

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 FT4-ST1 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • CSA C22.2 No.230 Tray Cables - Rated TC-ER (1/0 AWG and Larger)
  • CSA C22.2 No. 2556 / UL 2556 Cable Test Methods
  • CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (1/0 AWG and larger)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661
  • NFPA 502 Standard for Road Tunnels, Bridges, and Other Limited Access Highways (non-emergency circuits only)