DistributorSouthwire

Southwire

CU Compressed 15kV NLEPR Insulation 133% IL Black LSZH-TP Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46305

Type MV-105 Single Conductor Copper, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Thermoplastic SOLONON® Low Smoke Zero Halogen (LSZH-TP) Jacket, Rated UL. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (12) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)Conduit Size (in)(cm)
1 AWG1 AWG19190.3220.820.8002.032205.590.8602.18802.031.0402.647391100669303.4512.431.503.07.62 58553505
1/0 AWG1/0 AWG19190.3610.920.8402.132205.590.9002.29802.031.0802.748311237844382.8312.932.773.07.62 55078499
3/0 AWG3/0 AWG19190.4561.160.9342.372205.590.9942.52802.031.1742.98108616161342608.7214.035.563.58.89 67127099
4/0 AWG4/0 AWG19190.5121.300.9902.512205.591.0502.67802.031.2303.12126018751692767.4814.737.343.58.89 55078699
250 KCMIL250 KCMIL37370.5581.421.0442.652205.591.1042.80802.031.2843.26141721092000907.1815.439.124.010.16 45772899
350 KCMIL350 KCMIL37370.6611.681.1472.912205.591.2073.07802.031.3873.521795267128001270.0616.642.164.010.16 55078899
500 KCMIL500 KCMIL37370.7892.001.2523.182205.591.3123.33802.031.4923.792329346640001814.3717.945.474.511.43 55078999
750 KCMIL750 KCMIL61610.9682.461.4643.722205.591.5243.871102.791.7644.483358499760002721.5521.153.595.012.70 55079099
1500 KCMIL1500 KCMIL91911.3703.481.9004.832205.591.9604.981102.792.2005.5960318975120005443.1026.467.06 55064399
1 AWG1 AWG0.1280.190.1620.240.0470.070.0490.070.387 + j0.2640.387 + j0.2640.057 + j0.0480.057 + j0.04826952695175175185185225225250250 58553505
1/0 AWG1/0 AWG0.1020.150.1280.190.0430.060.0470.070.387 + j0.2640.387 + j0.2640.057 + j0.0480.057 + j0.04828162816200200215215260260290290 55078499
3/0 AWG3/0 AWG0.0640.100.0810.120.0370.060.0430.060.387 + j0.2640.387 + j0.2640.057 + j0.0480.057 + j0.04831103110260260275275345345385385 67127099
4/0 AWG4/0 AWG0.0510.080.0650.100.0340.050.0420.060.387 + j0.2640.387 + j0.2640.057 + j0.0480.057 + j0.04832843284295295315315400400445445 55078699
250 KCMIL250 KCMIL0.0430.060.0560.080.0250.040.0410.060.417 + j0.3540.417 + j0.3540.057 + j0.0410.057 + j0.04134513451325325345345445445495495 45772899
350 KCMIL350 KCMIL0.0310.050.0410.060.0280.040.0390.060.387 + j0.3040.387 + j0.3040.033 + j0.0300.033 + j0.03037703770390390415415550550610610 55078899
500 KCMIL500 KCMIL0.0220.030.0300.040.0250.040.0370.060.387 + j0.3040.387 + j0.3040.033 + j0.0300.033 + j0.03041674167465465500500685685765765 55078999
750 KCMIL750 KCMIL0.0140.020.0230.030.0210.030.0350.050.387 + j0.3270.387 + j0.3270.031 + j0.0340.031 + j0.03447524752565565610610885885990990 55079099
1500 KCMIL1500 KCMIL0.0070.010.0170.030.0160.020.0320.050.472 + j0.4120.472 + j0.4120.102 + j0.0420.102 + j0.042601060108158158808801345134515001500 55064399

Part numbers in this family (12)

By size:
Southwire #DescriptionConstructionPackaging
1 AWG (2)
585535991-19 CU 220 MILS NL-EPR 15KV 133% T/S BLACK SOLONON-TP UL1 AWG 1C 19SCUT TO LENGTH REEL
585535051-19 CU 220 MILS NL-EPR 15KV 133% T/S BLACK SOLONON-TP UL 5000 FT1 AWG 1C 19S5000 FT REEL
1/0 AWG (1)
550784991/0-19 CU 220 MILS NL-EPR 15KV 133% T/S BLACK SOLONON-TP UL1/0 AWG 1C 19SCUT TO LENGTH REEL
3/0 AWG (1)
671270993/0-19 CU 220 MILS NL-EPR 15KV 133% T/S BLACK SOLONON-TP UL3/0 AWG 1C 19SCUT TO LENGTH REEL
4/0 AWG (2)
550786994/0-19 CU 220 MILS NL-EPR 15KV 133% T/S BLACK SOLONON-TP UL4/0 AWG 1C 19SCUT TO LENGTH REEL
644152994/0-19 TINNED CU 220 MILS NL-EPR 15KV 133% T/S BLACK SOLONON-TP UL4/0 AWG 1C 19SCUT TO LENGTH REEL
250 kcmil (1)
45772899250-37 CU 220 MILS NL-EPR 15KV 133% T/S BLACK SOLONON-TP UL250 KCMIL 1C 37SCUT TO LENGTH REEL
350 kcmil (2)
55078899350-37 CU 220 MILS NL-EPR 15KV 133% T/S BLACK SOLONON-TP UL350 KCMIL 1C 37SCUT TO LENGTH REEL
64414999350-37 TINNED CU 220 MILS NL-EPR 15KV 133% T/S BLACK SOLONON-TP UL350 KCMIL 1C 37SCUT TO LENGTH REEL
500 kcmil (1)
55078999500-37 CU 220 MILS NL-EPR 15KV 133% T/S BLACK SOLONON-TP UL500 KCMIL 1C 37SCUT TO LENGTH REEL
750 kcmil (1)
55079099750-61 CU 220 MILS NL-EPR 15KV 133% T/S BLACK SOLONON-TP UL750 KCMIL 1C 61SCUT TO LENGTH REEL
1500 kcmil (1)
550643991500-91 CU 220 MILS NL-EPR 15KV 133% T/S BLACK SOLONON-TP UL1500 KCMIL 1C 91SCUT TO LENGTH REEL

Application & features

Southwire’s 15KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial when installed with a grounding conductor in close proximity that conforms to NEC section 311.36 and 250.4(A)(5), and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -25°C for cold bend. ST1 (low smoke) Rated for sizes 1/0 and larger. Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • ASTM B496 Compact Round Concentric-lay-standard copper
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 FT4-ST1 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (500kcmil & Larger)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661
  • NFPA 502 Standard for Road Tunnels, Bridges, and Other Limited Access Highways (non-emergency circuits only)