DistributorSouthwire

Southwire

CU Compressed 15kV NLEPR Insulation 133% IL Black CPE-TP Jacket. MV 105 - UL Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46403

Type MV-105 Three Conductor Copper, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Thermoplastic Chlorinated Polyethylene (CPE-TP) Jacket. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (7) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Ground SizeJacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
2 AWG2 AWG770.2820.720.7551.922205.590.8152.071x61x61102.792.0325.16216332191592722.1214.236.07 64338099
1/0 AWG1/0 AWG19190.3610.920.8402.132205.590.9002.291x41x41102.792.2225.642870427125341149.4015.539.37 58404199
2/0 AWG2/0 AWG19190.4051.030.8842.252205.590.9442.401x31x31102.792.3175.893297490631941448.7716.241.15 64690499
3/0 AWG3/0 AWG19190.4561.160.9342.372205.590.9942.521x31x31102.792.4186.143738556340271826.6116.942.93 58404299
4/0 AWG4/0 AWG19190.5121.300.9762.482205.591.0362.631x31x31102.792.5166.394300639950782303.3417.644.70 56025199
350 KCMIL350 KCMIL37370.6611.681.1472.912205.591.2073.071x21x21353.432.9297.446211924384003810.1720.552.07 56378599
500 KCMIL500 KCMIL37370.7892.001.2753.242205.591.3353.391x11x11353.433.2128.16805611989120005443.1022.456.90 56123299
2 AWG2 AWG0.1620.240.2040.300.0510.080.0470.070.356 + j0.2550.356 + j0.2550.019 + j0.0290.019 + j0.02925712571150150160160165165185185 64338099
1/0 AWG1/0 AWG0.1020.150.1280.190.0430.060.0430.060.357 + j0.2600.357 + j0.2600.024 + j0.0370.024 + j0.03728162816195195210210215215240240 58404199
2/0 AWG2/0 AWG0.0810.120.1020.150.0400.060.0420.060.473 + j0.3850.473 + j0.3850.105 + j0.0400.105 + j0.04029522952220220235235245245275275 64690499
3/0 AWG3/0 AWG0.0640.100.0810.120.0370.060.0400.060.358 + j0.2650.358 + j0.2650.020 + j0.0300.020 + j0.03031103110250250270270285285315315 58404299
4/0 AWG4/0 AWG0.0510.080.0650.100.0340.050.0390.060.359 + j0.2500.359 + j0.2500.031 + j0.0410.031 + j0.04132843284285285305305325325360360 56025199
350 KCMIL350 KCMIL0.0310.050.0410.060.0280.040.0360.050.359 + j0.2500.359 + j0.2500.031 + j0.0410.031 + j0.04137703770375375400400435435490490 56378599
500 KCMIL500 KCMIL0.0220.030.0300.040.0250.040.0340.050.359 + j0.2670.359 + j0.2670.020 + j0.0320.020 + j0.03241674167450450485485535535600600 56123299

Part numbers in this family (7)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
643380992-7 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X6 CU GW BLACK CPE-TP UL2 AWG 3C 7 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
584041991/0-19 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X4 CU GW BLACK CPE-TP UL1/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
646904992/0-19 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X3 CU GW BLACK CPE-TP UL2/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
584042993/0-19 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X3 CU GW BLACK CPE-TP UL3/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
560251994/0-19 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X3 CU GW BLACK CPE-TP UL4/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
56378599350-37 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X2 CU GW BLACK CPE-TP UL350 KCMIL 3C 37 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
56123299500-37 3/C CU 220 MILS NL-EPR 15KV 133% T/S 1X1 CU GW BLACK CPE-TP UL500 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL

Application & features

Southwire’s 15KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -40°C for cold bend and cold impact and marked with "LTGG" when CSA listed or dual UL/CSA listed. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661