DistributorSouthwire

Southwire

CU Compressed 15kV NLEPR Insulation 133% IL AIA Red PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46453

Type MV-105 Three Conductor Copper, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Aluminum Interlocked Armor (AIA), Polyvinyl Chloride (PVC) Jacket. Type MC For Cable Tray Use - Sunlight Resistant. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (13) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Ground SizeDiameter Over Armor (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
2 AWG2 AWG770.2820.720.7551.922205.590.8152.071x61x62.1325.42651.652.2645.75243936301592722.1215.840.13 55167189
1/0 AWG1/0 AWG19190.3610.920.8402.132205.590.9002.291x41x42.3195.89802.032.4856.313173472225341149.4017.343.94 55695199
2/0 AWG2/0 AWG19190.4051.030.8842.252205.590.9442.401x41x42.4106.12802.032.5766.543546527731941448.7718.045.72 95788689
4/0 AWG4/0 AWG19190.5121.300.9762.482205.591.0362.631x31x32.6096.63802.032.7757.054593683550782303.3419.449.28 55164889
250 KCMIL250 KCMIL37370.5581.421.0282.612205.591.0882.761x21x22.7216.91802.032.8877.335540824460002721.5520.251.31 44727699
350 KCMIL350 KCMIL37370.6611.681.1472.912205.591.2073.071x21x22.9787.56802.033.1447.996505968184003810.1722.055.88 55161489
500 KCMIL500 KCMIL37370.7892.001.2753.242205.591.3353.391x11x13.2488.25902.293.4288.71818512181120005443.1023.960.71 40916989
750 KCMIL750 KCMIL61610.9682.461.4643.722205.591.5243.871x1/01x1/03.6639.30902.293.8519.781146417060180008164.6626.968.33 55697799
2 AWG2 AWG0.1620.240.2040.300.0510.080.0470.070.296 + j0.1590.296 + j0.1590.018 + j0.0320.018 + j0.03225712571150150160160165165185185 55167189
1/0 AWG1/0 AWG0.1020.150.1280.190.0430.060.0430.060.319 + j0.1940.319 + j0.1940.020 + j0.0370.020 + j0.03728162816195195210210215215240240 55695199
2/0 AWG2/0 AWG0.0810.120.1020.150.0400.060.0420.060.355 + j0.2470.355 + j0.2470.023 + j0.0330.023 + j0.03329522952220220235235245245275275 95788689
4/0 AWG4/0 AWG0.0510.080.0650.100.0340.050.0390.060.296 + j0.1590.296 + j0.1590.018 + j0.0320.018 + j0.03232843284285285305305325325360360 55164889
250 KCMIL250 KCMIL0.0430.060.0560.080.0320.050.0380.060.292 + j0.1580.292 + j0.1580.019 + j0.0380.019 + j0.03834513451310310335335360360400400 44727699
350 KCMIL350 KCMIL0.0310.050.0410.060.0280.040.0360.050.295 + j0.1830.295 + j0.1830.021 + j0.0320.021 + j0.03237703770375375400400435435490490 55161489
500 KCMIL500 KCMIL0.0220.030.0300.040.0250.040.0340.050.271 + j0.1830.271 + j0.1830.023 + j0.0350.023 + j0.03541674167450450485485535535600600 40916989
750 KCMIL750 KCMIL0.0140.020.0230.030.0210.030.0320.050.324 + j0.1990.324 + j0.1990.019 + j0.0340.019 + j0.03447524752545545585585670670745745 55697799

Part numbers in this family (13)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
2 AWG (2)
551671992-7 3/C CU 220 NL-EPR T/S 1X6 CU GW AIA RED PVC JACKET 15KV 133% UL2 AWG 3C 7 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
551671892-7 3/C CU 220 NL-EPR T/S 1X6 CU GW AIA RED PVC JACKET 15KV 133% UL 3500 FT2 AWG 3C 7 STRBLACK-/BLACK-/BLACK-/-3500 FT REEL
1/0 AWG (1)
556951991/0-19 3/C CU 220 NL-EPR T/S 1X4 CU GW AIA RED PVC JACKET 15KV 133% UL1/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
2/0 AWG (2)
957886992/0-19 3/C CU 220 NL-EPR T/S 1X4 CU GW AIA RED PVC JACKET 15KV 133% UL2/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
957886892/0-19 3/C CU 220 NL-EPR T/S 1X4 CU GW AIA RED PVC JACKET 15KV 133% UL2500 FT2/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-2500 FT REEL
4/0 AWG (2)
551648994/0-19 3/C CU 220 NL-EPR T/S 1X3 CU GW AIA RED PVC JACKET 15KV 133% UL4/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
551648894/0-19 3/C CU 220 NL-EPR T/S 1X3 CU GW AIA RED PVC JACKET 15KV 133% UL2500 FT4/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-2500 FT REEL
250 kcmil (1)
44727699250-37 3/C CU 220 NL-EPR T/S 1X2 CU GW AIA RED PVC JACKET 15KV 133% UL250 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
350 kcmil (2)
55161499350-37 3/C CU 220 NL-EPR T/S 1X2 CU GW AIA RED PVC JACKET 15KV 133% UL350 KCMIL 3C 37 STRBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
55161489350-37 3/C CU 220 NL-EPR T/S 1X2 CU GW AIA RED PVC JACKET 15KV 133% UL1600 FT350 KCMIL 3C 37 STRBLACK-/BLACK-/BLACK-/-1600 FT REEL
500 kcmil (2)
40916999500-37 3/C CU 220 NL-EPR T/S 1X1 CU GW AIA RED PVC JACKET 15KV 133% UL500 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL
40916989500-37 3/C CU 220 NL-EPR T/S 1X1 CU GW AIA RED PVC JACKET 15KV 133% UL1600 FT500 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-1600 FT REEL
750 kcmil (1)
55697799750-61 3/C CU 220 NL-EPR T/S 1X1/0 CU GW AIA RED PVC JACKET 15KV 133% UL750 KCMIL 3C 61SBLACK-/BLACK-/BLACK-/-CUT TO LENGTH REEL

Application & features

Southwire’s 15KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -40°C for cold bend and cold impact and marked with "LTGG" when CSA listed or dual UL/CSA listed. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs./FT maximum sidewall pressure.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661