DistributorSouthwire

Southwire

CU Compressed 15kV NLEPR Insulation 133% IL AIA Red PVC Jacket. MV 105 - 50% Ground - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46455

Type MV-105 Three Conductor Copper, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, 50% Ground Aluminum Interlocked Armor (AIA), Polyvinyl Chloride (PVC) Jacket. Silicone Free. Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (5) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Ground SizeDiameter Over Armor (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)
1/0 AWG1/0 AWG19190.3610.920.8402.132205.590.9002.293x63x62.3195.89802.032.4856.313289489525341149.4017.343.94 67941999
250 KCMIL250 KCMIL37370.5581.421.0282.612205.591.0882.763x43x42.7236.921353.432.9937.605578830160002721.5520.953.09 57871299
350 KCMIL350 KCMIL37370.6611.681.1272.862205.591.1873.013x23x22.9357.45802.033.1017.886673993184003810.1721.755.12 56029399
500 KCMIL500 KCMIL37370.7892.001.2523.182205.591.3123.333x13x13.2058.14902.293.3938.62861112815120005443.1023.760.20 60521299
750 KCMIL750 KCMIL61610.9682.461.4643.722205.591.5243.873x2/03x2/03.6639.30902.293.8519.781209317996180008164.6626.968.33 57620299
1/0 AWG1/0 AWG0.1020.150.1280.190.0430.060.0430.060.395 + j0.3230.395 + j0.3230.042 + j0.0400.042 + j0.04028162816195195210210215215240240 67941999
250 KCMIL250 KCMIL0.0430.060.0560.080.0320.050.0380.060.396 + j0.3230.396 + j0.3230.042 + j0.0390.042 + j0.03934513451310310335335360360400400 57871299
350 KCMIL350 KCMIL0.0310.050.0410.060.0280.040.0360.050.396 + j0.3230.396 + j0.3230.042 + j0.0390.042 + j0.03937703770375375400400435435490490 56029399
500 KCMIL500 KCMIL0.0220.030.0300.040.0250.040.0340.050.397 + j0.3300.397 + j0.3300.040 + j0.0340.040 + j0.03441674167450450485485535535600600 60521299
750 KCMIL750 KCMIL0.0140.020.0230.030.0210.030.0320.050.398 + j0.3020.398 + j0.3020.046 + j0.0350.046 + j0.03547524752545545585585670670745745 57620299

Part numbers in this family (5)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
679419991/0-19 3/C CU 220 NL-EPR T/S 3X6 CU GW AIA RED PVC JACKET 15KV 133% UL1/0 AWG 3C 19 STRBLACK-/BLACK-/BLACK-/-/-/-CUT TO LENGTH REEL
57871299250-37 3/C CU 220 MILS NL-EPR 15KV 133% T/S 3X4 CU GW RED PVC UL250 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-/-/-CUT TO LENGTH REEL
56029399350-37 3/C CU 220 NL-EPR T/S 3X2 CU GW AIA RED PVC JACKET 15KV 133% UL350 KCMIL 3C 37 STRBLACK-/BLACK-/BLACK-/-/-/-CUT TO LENGTH REEL
60521299500-37 3/C CU 220 NL-EPR T/S 3X1 CU GW AIA RED PVC JACKET 15KV 133% UL500 KCMIL 3C 37SBLACK-/BLACK-/BLACK-/-/-/-CUT TO LENGTH REEL
57620299750-61 3/C CU 220 NL-EPR T/S 3X2/0 CU GW AIA RED PVC JACKET 15KV 133% UL750 KCMIL 3C 61SBLACK-/BLACK-/BLACK-/-/-/-CUT TO LENGTH REEL

Application & features

Southwire’s 15KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -40°C for cold bend and cold impact and marked with "LTGG" when CSA listed or dual UL/CSA listed. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs./ FT maximum sidewall pressure. The ground is sized to equal 50% of the phase conductor. Silicone free cable.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679 Cable Conductor Identification Method 3 (1-BLACK, 2-RED, 3-BLUE)
  • ICEA S-58-679 Control Cable Conductor Identification Method 4
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661
  • GM 5E