DistributorSouthwire

Southwire

CU Compact 15kV NLEPR Insulation 133% IL Black SIM-PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial

Southwire #
SPEC46319

Type MV-105 Single Conductor Compact Copper, 220 Mil No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, SIMpull® Polyvinyl Chloride (PVC) Jacket, Dual Rated UL/CSA

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (7) ↓

Available sizes & constructions

Cond. SizeCond. StrandsDiameter Over Conductor (in)(cm)Diameter Over Insulation (in)(cm)Insulation Thickness (mils)(mm)Diameter Over Shield (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)Max Pull Tension (lbs)(kg)Min. Bend Radius (in)(cm)Conduit Size (in)(cm)
2 AWG2 AWG770.2680.680.7461.892205.590.8062.05802.030.9862.50635945530240.4011.829.973.07.62 66914299
1/0 AWG1/0 AWG19190.3360.850.8142.072205.590.8742.22802.031.0542.688001191844382.8312.632.003.07.62 64720399
4/0 AWG4/0 AWG19190.4741.200.9532.422205.591.0132.57802.031.1933.03101215061692767.4814.336.323.58.89 64092199
350 KCMIL350 KCMIL35350.6151.561.1022.802205.591.1622.95802.031.3423.411747260028001270.0616.140.894.010.16 64720799
500 KCMIL500 KCMIL35350.7351.871.2303.122205.591.2903.28802.031.4703.732301342440001814.3717.644.704.511.43 55399899
750 KCMIL750 KCMIL61610.9082.311.4043.572205.591.4953.80802.031.7354.413331495760002721.5520.852.835.012.70 56160301
2 AWG2 AWG0.1620.240.2040.300.0530.080.0520.080.446 + j0.3910.446 + j0.3910.081 + j0.0440.081 + j0.04425282528155155165165195195215215 66914299
1/0 AWG1/0 AWG0.1020.150.1280.190.0460.070.0480.070.446 + j0.3910.446 + j0.3910.081 + j0.0440.081 + j0.04427382738200200215215260260290290 64720399
4/0 AWG4/0 AWG0.0510.080.0650.100.0360.050.0430.060.446 + j0.3910.446 + j0.3910.081 + j0.0440.081 + j0.04431663166295295315315400400445445 64092199
350 KCMIL350 KCMIL0.0310.050.0410.060.0300.040.0400.060.446 + j0.2840.446 + j0.2840.105 + j0.0480.105 + j0.04836283628390390415415550550610610 64720799
500 KCMIL500 KCMIL0.0220.030.0300.040.0260.040.0370.060.444 + j0.4870.444 + j0.4870.081 + j0.0370.081 + j0.03739993999465465500500685685765765 55399899
750 KCMIL750 KCMIL0.0140.020.0230.030.0220.030.0350.050.444 + j0.2840.444 + j0.2840.106 + j0.050.106 + j0.0545664566565565610610885885990990 56160301

Part numbers in this family (7)

By size:
Southwire #DescriptionConstructionPackaging
2 AWG (1)
669142992-7 MB CPT CU 220 MILS NL-EPR 15KV 133% T/S BLACK SIMpull PVC JACKET UL/CSA2 AWG 1C 7SCUT TO LENGTH REEL
1/0 AWG (1)
647203991/0-19 CPT CU 220 MILS NL-EPR 15KV 133% T/S BLACK SIMpull PVC JACKET UL/CSA1/0 AWG 1C 19SCUT TO LENGTH REEL
4/0 AWG (1)
640921994/0-19 CPT CU 220 MILS NL-EPR 15KV 133% T/S BLACK SIMpull PVC JACKET UL4/0 AWG 1C 19SCUT TO LENGTH REEL
350 kcmil (1)
64720799350-35 CPT CU 220 MILS NL-EPR 15KV 133% T/S BLACK SIMpull PVC JACKET UL/CSA350 KCMIL 1C 35SCUT TO LENGTH REEL
500 kcmil (1)
55399899500-35 CPT CU 220 MILS NL-EPR 15KV 133% T/S BLACK SIMpull PVC JACKET UL500 KCMIL 1C 35SCUT TO LENGTH REEL
750 kcmil (2)
56160399750-61 CPT CU 220 MILS NL-EPR 15KV 133% T/S BLACK SIMpull PVC JACKET UL750 KCMIL 1C 61SCUT TO LENGTH REEL
56160301750-61 CPT CU 220 MILS NL-EPR 15KV 133% T/S BLACK SIMpull PVC JACKET UL2500 FT750 KCMIL 1C 61S2500 FT REEL

Application & features

Southwire’s 15kV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial when installed with a grounding conductor in close proximity that conforms to NEC section 311.36 and 250.4(A)(5), and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -25°C for cold bend and cold impact and marked with "LTDD" when CSA listed or dual UL/CSA listed. PVC jacket is made with SIM technology and has a coefficient of friction COF of 0.2. Cable can be installed in conduit without the aid of lubrication. Rated for 1000 lb/ft maximum sidewall pressure.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • ASTM B496 Compact Round Concentric-lay-standard copper
  • UL 1072 Medium-Voltage Power Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • CSA C22.2 No.230 Tray Cables - Rated TC-ER (1/0 AWG and Larger)
  • CSA C22.2 No. 2556 / UL 2556 Cable Test Methods
  • CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications - 5 to 46 KV
  • ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
  • ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 - 46kV
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)
  • AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661