DistributorSouthwire

Southwire

CU 600V XLPE Insulation Thermoplastic CPE-TP Jacket XHHW-2. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free

Southwire #
SPEC45053

Type TC-ER Control Cable 600Volt Copper Cross Linked Polyethylene (XLPE) Insulation XHHW-2 Thermoplastic Chlorinated Polyethylene (CPE-TP) Jacket, Control Cable Conductor Identification Method 1 Table 2. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (20) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsInsulation Thickness (mils)(mm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Copper Weight (lbs/1000')(kgs/km)Approx. Weight (lbs/1000')(kgs/km)DC Resistance at 25C (ohms/1000')(ohms/km)AC Resistance at 75C (ohms/1000')(ohms/km)Min. Bend Radius (in)(cm)Allowable Ampacity Raceway 75CAllowable Ampacity Raceway 90C
14 AWG14 AWG2277300.76451.140.3550.902537671002.6313.923.1704.721.43.5620202525 89067499
14 AWG14 AWG3377300.76451.140.3760.963857911352.6313.923.1704.721.53.8120202525 89067599
14 AWG14 AWG4477300.76451.140.4091.0451761111652.6313.923.1704.721.64.0616162020 89067699
14 AWG14 AWG5577300.76451.140.4471.1464951291922.6313.923.1704.721.84.5716162020 89067701
14 AWG14 AWG7777300.76451.140.4861.23891321722562.6313.923.1704.721.94.8314141717 89067899
14 AWG14 AWG121277300.76601.520.6701.701532282994452.6313.923.1704.722.76.8610101212 55040701
12 AWG12 AWG2277300.76451.140.3880.994060891321.6622.472.0022.981.64.0625253030 55041199
12 AWG12 AWG3377300.76451.140.4121.0561911201791.6622.472.0022.981.64.0625253030 89068199
12 AWG12 AWG4477300.76451.140.4491.14811211542291.6622.472.0022.981.84.5720202424 89068299
12 AWG12 AWG5577300.76451.140.4911.251011501782651.6622.472.0022.982.05.0820202424 89068301
12 AWG12 AWG121277300.76601.520.7381.872443634086071.6622.472.0022.983.07.6212121515 89068401
10 AWG10 AWG3377300.76451.140.4761.21971441692511.0401.551.2531.861.94.8335354040 89068599
10 AWG10 AWG4477300.76451.140.5471.391291922283391.0401.551.2531.862.25.5928283232 89068603
10 AWG10 AWG5577300.76601.520.6031.531612402754091.0401.551.2531.862.46.1028283232 55042099
10 AWG10 AWG7777300.76601.520.6571.672263363645421.0401.551.2531.862.66.6024242828 55042199

Part numbers in this family (20)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
14 AWG · 2 conductors (1)
8906749914-7 2/C CU XHHW/CPE PHASE ID TYPE TC 600V BLACK14 AWG 2C 7 STRBLACK/REDCUT TO LENGTH REEL
14 AWG · 3 conductors (1)
8906759914-7 3/C CU XHHW/CPE PHASE ID TYPE TC-ER 600V BLACK14 AWG 3C 7 STRBLACK/RED/BLUECUT TO LENGTH REEL
14 AWG · 4 conductors (1)
8906769914-7 CU 4/C XHHW/CPE-TP TYPE TC 600V BLACK-14 AWG 4C 7 STRBLACK/RED/BLUE/ORANGECUT TO LENGTH REEL
14 AWG · 5 conductors (2)
8906779914-7 5/C CU XHHW/CPE PHASE ID TYPE TC-ER 600V BLACK14 AWG 5C 7SBLACK/RED/BLUE/ORANGE/YELLOWCUT TO LENGTH REEL
8906770114-7 5/C CU XHHW/CPE PHASE ID TYPE TC-ER 600V BLACK 1000 FT14 AWG 5C 7SBLACK/RED/BLUE/ORANGE/YELLOW1000 FT REEL
14 AWG · 7 conductors (1)
8906789914-7 7/C CU XHHW/CPE PHASE ID TYPE TC-ER 600V BLACK14 AWG 7C 7SBLACK/RED/BLUE/ORANGE/YELLOW/BROWN/RED-BLACK STRIPECUT TO LENGTH REEL
14 AWG · 12 conductors (2)
5504079914-7 12/C CU XHHW/CPE PHASE ID TYPE TC-ER 600V BLACK14 AWG 12C 7SBLACK/RED/BLUE/ORANGE/YELLOW/BROWN/RED-BLACK STRIPE/BLUE-BLACK STRIPE/ORANGE-BLACK STRIPE/YELLOW-BLACK STRIPE/BROWN-BLACK STRIPE/BLACK-RED STRIPECUT TO LENGTH REEL
5504070114-7 12/C CU XHHW/CPE PHASE ID TYPE TC-ER 600V BLACK 1000 FT14 AWG 12C 7SBLACK/RED/BLUE/ORANGE/YELLOW/BROWN/RED-BLACK STRIPE/BLUE-BLACK STRIPE/ORANGE-BLACK STRIPE/YELLOW-BLACK STRIPE/BROWN-BLACK STRIPE/BLACK-RED STRIPE1000 FT REEL
12 AWG · 2 conductors (1)
5504119912-7 2/C CU XHHW/CPE PHASE ID TYPE TC 600V BLACK12 AWG 2C 7 STRBLACK/REDCUT TO LENGTH REEL
12 AWG · 3 conductors (1)
8906819912-7 3/C CU XHHW/CPE PHASE ID TYPE TC-ER 600V BLACK12 AWG 3C 7SBLACK/RED/BLUECUT TO LENGTH REEL
12 AWG · 4 conductors (1)
8906829912-7 4/C CU XHHW/CPE PHASE ID TYPE TC-ER 600V BLACK12 AWG 4C 7 STRBLACK/RED/BLUE/ORANGECUT TO LENGTH REEL
12 AWG · 5 conductors (2)
8906839912-7 5/C CU XHHW/CPE PHASE ID TYPE TC-ER 600V BLACK12 AWG 5C 7SBLACK/RED/BLUE/ORANGE/YELLOWCUT TO LENGTH REEL
8906830112-7 5/C CU XHHW/CPE PHASE ID TYPE TC-ER 600V BLACK 2000 FT12 AWG 5C 7SBLACK/RED/BLUE/ORANGE/YELLOW2000 FT REEL
12 AWG · 12 conductors (2)
8906849912-7 12/C CU XHHW/CPE PHASE ID TYPE TC-ER 600V BLACK12 AWG 12C 7SBLACK/RED/BLUE/ORANGE/YELLOW/BROWN/RED-BLACK STRIPE/BLUE-BLACK STRIPE/ORANGE-BLACK STRIPE/YELLOW-BLACK STRIPE/BROWN-BLACK STRIPE/BLACK-RED STRIPECUT TO LENGTH REEL
8906840112-7 12/C CU XHHW/CPE PHASE ID TYPE TC-ER 600V BLACK 2000 FT12 AWG 12C 7SBLACK/RED/BLUE/ORANGE/YELLOW/BROWN/RED-BLACK STRIPE/BLUE-BLACK STRIPE/ORANGE-BLACK STRIPE/YELLOW-BLACK STRIPE/BROWN-BLACK STRIPE/BLACK-RED STRIPE2000 FT REEL
10 AWG · 3 conductors (1)
8906859910-7 3/C CU XHHW/CPE PHASE ID TYPE TC-ER 600V BLACK10 AWG 3C 7 STRBLACK/RED/BLUECUT TO LENGTH REEL
10 AWG · 4 conductors (2)
8906869910-7 4/C CU XHHW/CPE PHASE ID TYPE TC-ER 600V BLACKMATERIAL BLOCKED OBSOLETE. NO REPLACEMENT MATERIAL #10 AWG 4C 7 STRBLACK/RED/BLUE/ORANGECUT TO LENGTH REEL
8906860310-7 4/C CU XHHW/CPE PHASE ID TYPE TC-ER 600V BLACK10 AWG 4C 7 STRBLACK/RED/BLUE/ORANGE3000 FT REEL
10 AWG · 5 conductors (1)
5504209910-7 5/C CU XHHW/CPE PHASE ID TYPE TC-ER 600V BLACK10 AWG 5C 7SBLACK/RED/BLUE/ORANGE/YELLOWCUT TO LENGTH REEL
10 AWG · 7 conductors (1)
5504219910-7 7/C CU XHHW/CPE PHASE ID TYPE TC-ER 600V BLACK10 AWG 7C 7SBLACK/RED/BLUE/ORANGE/YELLOW/BROWN/RED-BLACK STRIPECUT TO LENGTH REEL

Application & features

Southwire’s 600 Volt Type TC-ER control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. Sunlight Resistant - For Direct Burial - Silicone Free

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1277 Electrical Power and Control Tray Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2
  • ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test