CU 600V XLPE Insulation. RHH/RHW-2 PV
- Southwire #
- SPEC45413
Single Conductor Photovoltaic (Type PV) Power Cable 600 Volt Copper Conductor XLPE Insulation. Sizes 14 AWG through 1000 kcmil. Heat, Moisture, Sunlight Resistant RoHS. 90°C
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (7) ↓Available sizes & constructions
| Cond. Size | Conductor Number | Cond. Strands | Diameter Over Conductor (in)(cm) | Insulation Thickness (mils)(mm) | Approx. OD (inches)(cm) | Copper Weight (lbs/1000')(kgs/km) | Approx. Weight (lbs/1000')(kgs/km) | |
|---|---|---|---|---|---|---|---|---|
| 12 AWG12 AWG | 11 | 1919 | 0.0900.23 | 601.52 | 0.2130.54 | 2030 | 3654 | 56794601 |
| 10 AWG10 AWG | 11 | 1919 | 0.1170.30 | 601.52 | 0.2310.59 | 3248 | 4770 | 56794701 |
| 12 AWG12 AWG | 11 | 0.92.29 | 1.6622.47 | 2.0022.98 | 0.0540.08 | 2525 | 3030 | 56794601 |
| 10 AWG10 AWG | 11 | 0.92.29 | 1.0401.55 | 1.2531.86 | 0.0500.07 | 3535 | 4040 | 56794701 |
| AWG/kcmilAWG/kcmil | ||||||||
| 1212 | ||||||||
| 1010 |
Part numbers in this family (7)
By size:
| Southwire # | Description | Construction | Packaging | |
|---|---|---|---|---|
| 12 AWG (1) | ||||
| 56794601 | 12-19 CU PV SINGLE LAYER XLP 600V BLACK VW-1 1000 FT | 12 AWG 1C 19S | 1000 FT SPOOL | |
| 10 AWG (6) | ||||
| 56794701 | 10-19 CU PV SINGLE LAYER XLP 600V BLACK 1000 FT | 10 AWG 1C 19S | 1000 FT SPOOL | |
| 56794702 | 10-19 CU PV SINGLE LAYER XLP 600V BLACK 2500 FT | 10 AWG 1C 19S | 2500 FT REEL | |
| 56794705 | 10-19 CU PV SINGLE LAYER XLP 600V BLACK 500 FT | 10 AWG 1C 19S | 500 FT SPOOL | |
| 56794706 | 10-19 CU PV SINGLE LAYER XLP 600V BLACK 600 FTMATERIAL BLOCKED OBSOLETE.NO REPLACEMENT MATERIAL # | 10 AWG 1C 19S | 600 FT COILPAK | |
| 56794901 | 10-19 CU PV SINGLE LAYER XLP 600V WHITE 2500 FT | 10 AWG 1C 19S | 2500 FT REEL | |
| 56794802 | 10-19 CU PV XLP 600V RED 500 FT | 10 AWG 1C 19S | 500 FT SPOOL | |
Application & features
Southwire’s 600 Volt power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.
Standards & references
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- ASTM B787 19 Wire Combination Unilay-Stranded Copper Conductors
- UL 44 Thermoset-Insulated Wires and Cables
- UL 4703 Standard for Photovoltaic Wire
- Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661
- VW-1 Vertical-Wire Flame Test (Optional)