DistributorSouthwire

Southwire

CU 600V XLPE Insulation ARMOR-X® PVC Jacket XHHW-2 VFD Cable. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free

Southwire #
SPEC45226

Type MC-HL Control Cable 600 Volt Copper Conductors, Cross Linked Polyethylene (XLPE) Insulation XHHW-2 Continuous Corrugated Welded Armor ARMOR-X®, Polyvinyl Chloride (PVC) Jacket with 3 Bare CU Ground

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (12) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsInsulation Thickness (mils)(mm)Diameter Over Armor (in)(cm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Copper Weight (lbs/1000')(kgs/km)Approx. Weight (lbs/1000')(kgs/km)DC Resistance at 25C (ohms/1000')(ohms/km)AC Resistance at 75C (ohms/1000')(ohms/km)Min. Bend Radius (in)(cm)Allowable Ampacity Raceway 75CAllowable Ampacity Raceway 90C
14 AWG14 AWG3377300.760.5301.35501.270.6361.6253791912842.6313.923.1704.724.511.4320202525 55058689
14 AWG14 AWG4477300.760.6101.55501.270.7161.8266982233322.6313.923.1704.725.012.7016162020 55058789
12 AWG12 AWG3377300.760.4801.22501.270.6361.62851262243331.6622.472.0022.984.511.4325253030 55058889
12 AWG12 AWG4477300.760.6501.65501.270.7561.921051562764111.6622.472.0022.985.313.4620202424 55058989
10 AWG10 AWG3377300.760.6101.55501.270.7161.821352012924351.0401.551.2531.865.012.7035354040 55059189
10 AWG10 AWG4477300.760.7001.78501.270.8062.051672493545271.0401.551.2531.865.614.2228283232 55059289

Part numbers in this family (12)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
14 AWG · 3 conductors (2)
5505869914-7 3/C CPRESS CU XHHW-2 3X#18 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET14 AWG 3C 7 STRBLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/18 AWG BARE GRND/18 AWG BARE GRND/18 AWG BARE GRNDCUT TO LENGTH REEL
5505868914-7 3/C CPRESS CU XHHW-2 3X#18 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET 5000 FT14 AWG 3C 7 STRBLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/18 AWG BARE GRND/18 AWG BARE GRND/18 AWG BARE GRND5000 FT REEL
14 AWG · 4 conductors (2)
5505879914-7 4/C CPRESS CU XHHW-2 3X#18 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET14 AWG 4C 7 STRBLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/ORANGE-4-FOUR/18 AWG BARE GRND/18 AWG BARE GRND/18 AWGBARE GRNDCUT TO LENGTH REEL
5505878914-7 4/C CPRESS CU XHHW-2 3X#18 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET 5000 FT14 AWG 4C 7 STRBLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/ORANGE-4-FOUR/18 AWG BARE GRND/18 AWG BARE GRND/18 AWGBARE GRND5000 FT REEL
12 AWG · 3 conductors (2)
5505889912-7 3/C CPRESS CU XHHW-2 3X#16 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET12 AWG 3C 7SBLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/16 AWG BARE GRND/16 AWG BARE GRND/16 AWG BARE GRNDCUT TO LENGTH REEL
5505888912-7 3/C CPRESS CU XHHW-2 3X#16 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET 5000 FT12 AWG 3C 7SBLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/16 AWG BARE GRND/16 AWG BARE GRND/16 AWG BARE GRND5000 FT REEL
12 AWG · 4 conductors (2)
5505899912-7 4/C CPRESS CU XHHW-2 3X#16 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET12 AWG 4C 7 STRBLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/ORANGE-4-FOUR/16 AWG BARE GRND/16 AWG BARE GRND/16 AWGBARE GRNDCUT TO LENGTH REEL
5505898912-7 4/C CPRESS CU XHHW-2 3X#16 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET 5000 FT12 AWG 4C 7 STRBLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/ORANGE-4-FOUR/16 AWG BARE GRND/16 AWG BARE GRND/16 AWGBARE GRND5000 FT REEL
10 AWG · 3 conductors (2)
5505919910-7 3/C CPRESS CU XHHW-2 3X#14 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET10 AWG 3C 7 STRBLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/14 AWG BARE GRND/14 AWG BARE GRND/14 AWG BARE GRNDCUT TO LENGTH REEL
5505918910-7 3/C CPRESS CU XHHW-2 3X#14 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET 5000 FT10 AWG 3C 7 STRBLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/14 AWG BARE GRND/14 AWG BARE GRND/14 AWG BARE GRND5000 FT REEL
10 AWG · 4 conductors (2)
5505929910-7 4/C CPRESS CU XHHW-2 3X#14 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET10 AWG 4C 7 STRBLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/ORANGE-4-FOUR/14 AWG BARE GRND/14 AWG BARE GRND/14 AWGBARE GRNDCUT TO LENGTH REEL
5505928910-7 4/C CPRESS CU XHHW-2 3X#14 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET 5000 FT10 AWG 4C 7 STRBLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/ORANGE-4-FOUR/14 AWG BARE GRND/14 AWG BARE GRND/14 AWGBARE GRND5000 FT REEL

Application & features

Southwire's 600 Volt Type MC-HL ARMOR-X® control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1569 Metal-Clad Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations
  • CSA C22.2 No. 123 Metal Sheathed Cables
  • CSA C22.2 No. 174 Cables in Hazardous Locations
  • ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2
  • ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • ICEA S-138-738 Power Cables Rated 2000 Volts or Less for use Between Variable Frequency Drives and Motors (3 conductor constructions only)
  • IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu/hr) and ICEA T-29-520 - (210,000 Btu/hr)