CU 600V XLPE Insulation ARMOR-X® PVC Jacket XHHW-2 VFD Cable. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free
- Southwire #
- SPEC45226
Type MC-HL Control Cable 600 Volt Copper Conductors, Cross Linked Polyethylene (XLPE) Insulation XHHW-2 Continuous Corrugated Welded Armor ARMOR-X®, Polyvinyl Chloride (PVC) Jacket with 3 Bare CU Ground
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (12) ↓Available sizes & constructions
| Cond. Size | Conductor Number | Cond. Strands | Insulation Thickness (mils)(mm) | Diameter Over Armor (in)(cm) | Jacket Thickness (mils)(mm) | Approx. OD (inches)(cm) | Copper Weight (lbs/1000')(kgs/km) | Approx. Weight (lbs/1000')(kgs/km) | DC Resistance at 25C (ohms/1000')(ohms/km) | AC Resistance at 75C (ohms/1000')(ohms/km) | Min. Bend Radius (in)(cm) | Allowable Ampacity Raceway 75C | Allowable Ampacity Raceway 90C | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 14 AWG14 AWG | 33 | 77 | 300.76 | 0.5301.35 | 501.27 | 0.6361.62 | 5379 | 191284 | 2.6313.92 | 3.1704.72 | 4.511.43 | 2020 | 2525 | 55058689 |
| 14 AWG14 AWG | 44 | 77 | 300.76 | 0.6101.55 | 501.27 | 0.7161.82 | 6698 | 223332 | 2.6313.92 | 3.1704.72 | 5.012.70 | 1616 | 2020 | 55058789 |
| 12 AWG12 AWG | 33 | 77 | 300.76 | 0.4801.22 | 501.27 | 0.6361.62 | 85126 | 224333 | 1.6622.47 | 2.0022.98 | 4.511.43 | 2525 | 3030 | 55058889 |
| 12 AWG12 AWG | 44 | 77 | 300.76 | 0.6501.65 | 501.27 | 0.7561.92 | 105156 | 276411 | 1.6622.47 | 2.0022.98 | 5.313.46 | 2020 | 2424 | 55058989 |
| 10 AWG10 AWG | 33 | 77 | 300.76 | 0.6101.55 | 501.27 | 0.7161.82 | 135201 | 292435 | 1.0401.55 | 1.2531.86 | 5.012.70 | 3535 | 4040 | 55059189 |
| 10 AWG10 AWG | 44 | 77 | 300.76 | 0.7001.78 | 501.27 | 0.8062.05 | 167249 | 354527 | 1.0401.55 | 1.2531.86 | 5.614.22 | 2828 | 3232 | 55059289 |
Part numbers in this family (12)
| Southwire # | Description | Construction | Conductor Color | Packaging | |
|---|---|---|---|---|---|
| 14 AWG · 3 conductors (2) | |||||
| 55058699 | 14-7 3/C CPRESS CU XHHW-2 3X#18 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET | 14 AWG 3C 7 STR | BLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/18 AWG BARE GRND/18 AWG BARE GRND/18 AWG BARE GRND | CUT TO LENGTH REEL | |
| 55058689 | 14-7 3/C CPRESS CU XHHW-2 3X#18 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET 5000 FT | 14 AWG 3C 7 STR | BLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/18 AWG BARE GRND/18 AWG BARE GRND/18 AWG BARE GRND | 5000 FT REEL | |
| 14 AWG · 4 conductors (2) | |||||
| 55058799 | 14-7 4/C CPRESS CU XHHW-2 3X#18 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET | 14 AWG 4C 7 STR | BLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/ORANGE-4-FOUR/18 AWG BARE GRND/18 AWG BARE GRND/18 AWGBARE GRND | CUT TO LENGTH REEL | |
| 55058789 | 14-7 4/C CPRESS CU XHHW-2 3X#18 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET 5000 FT | 14 AWG 4C 7 STR | BLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/ORANGE-4-FOUR/18 AWG BARE GRND/18 AWG BARE GRND/18 AWGBARE GRND | 5000 FT REEL | |
| 12 AWG · 3 conductors (2) | |||||
| 55058899 | 12-7 3/C CPRESS CU XHHW-2 3X#16 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET | 12 AWG 3C 7S | BLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/16 AWG BARE GRND/16 AWG BARE GRND/16 AWG BARE GRND | CUT TO LENGTH REEL | |
| 55058889 | 12-7 3/C CPRESS CU XHHW-2 3X#16 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET 5000 FT | 12 AWG 3C 7S | BLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/16 AWG BARE GRND/16 AWG BARE GRND/16 AWG BARE GRND | 5000 FT REEL | |
| 12 AWG · 4 conductors (2) | |||||
| 55058999 | 12-7 4/C CPRESS CU XHHW-2 3X#16 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET | 12 AWG 4C 7 STR | BLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/ORANGE-4-FOUR/16 AWG BARE GRND/16 AWG BARE GRND/16 AWGBARE GRND | CUT TO LENGTH REEL | |
| 55058989 | 12-7 4/C CPRESS CU XHHW-2 3X#16 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET 5000 FT | 12 AWG 4C 7 STR | BLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/ORANGE-4-FOUR/16 AWG BARE GRND/16 AWG BARE GRND/16 AWGBARE GRND | 5000 FT REEL | |
| 10 AWG · 3 conductors (2) | |||||
| 55059199 | 10-7 3/C CPRESS CU XHHW-2 3X#14 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET | 10 AWG 3C 7 STR | BLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/14 AWG BARE GRND/14 AWG BARE GRND/14 AWG BARE GRND | CUT TO LENGTH REEL | |
| 55059189 | 10-7 3/C CPRESS CU XHHW-2 3X#14 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET 5000 FT | 10 AWG 3C 7 STR | BLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/14 AWG BARE GRND/14 AWG BARE GRND/14 AWG BARE GRND | 5000 FT REEL | |
| 10 AWG · 4 conductors (2) | |||||
| 55059299 | 10-7 4/C CPRESS CU XHHW-2 3X#14 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET | 10 AWG 4C 7 STR | BLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/ORANGE-4-FOUR/14 AWG BARE GRND/14 AWG BARE GRND/14 AWGBARE GRND | CUT TO LENGTH REEL | |
| 55059289 | 10-7 4/C CPRESS CU XHHW-2 3X#14 CU GW ARMOR-XTRA MC-HL CSA RA90-HL 600VBLACK PVC JACKET 5000 FT | 10 AWG 4C 7 STR | BLACK-1-ONE/RED-2-TWO/BLUE-3-THREE/ORANGE-4-FOUR/14 AWG BARE GRND/14 AWG BARE GRND/14 AWGBARE GRND | 5000 FT REEL | |
Application & features
Southwire's 600 Volt Type MC-HL ARMOR-X® control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, 250°C for short circuit conditions. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503.
Standards & references
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- UL 44 Thermoset-Insulated Wires and Cables
- UL 1569 Metal-Clad Cables
- UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
- UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classified) Locations
- CSA C22.2 No. 123 Metal Sheathed Cables
- CSA C22.2 No. 174 Cables in Hazardous Locations
- ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2
- ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
- ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
- ICEA S-138-738 Power Cables Rated 2000 Volts or Less for use Between Variable Frequency Drives and Motors (3 conductor constructions only)
- IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu/hr) and ICEA T-29-520 - (210,000 Btu/hr)