DistributorSouthwire

Southwire

CU 600V PVC-Nylon Insulation PVC Jacket THHN/THWN With Green Ground. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free

Southwire #
SPEC45102

Type TC-ER Control Cable 600Volt Copper Conductors, Polyvinyl Chloride (PVC) with nylon layer Insulation THHN/THWN Polyvinyl Chloride (PVC) Jacket with 1 Insulated Green CU Ground, Control Cable Conductor Identification Method 1 Table 2

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (11) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsInsulation Thickness (mils)(mm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Copper Weight (lbs/1000')(kgs/km)Approx. Weight (lbs/1000')(kgs/km)DC Resistance at 25C (ohms/1000')(ohms/km)AC Resistance at 75C (ohms/1000')(ohms/km)Min. Bend Radius (in)(cm)Allowable Ampacity Raceway 75CAllowable Ampacity Raceway 90C
14 AWG14 AWG3377150.38451.140.3490.895176901342.6313.923.1704.721.43.5620202525 60680699
14 AWG14 AWG4477150.38451.140.3840.9864951111652.6313.923.1704.721.53.8116162020 60681499
12 AWG12 AWG3377150.38451.140.3640.92811211311951.6622.472.0022.981.53.8125253030 60672301
12 AWG12 AWG4477150.38451.140.4061.031011501572341.6622.472.0022.981.64.0620202424 60679899
10 AWG10 AWG2277200.51451.140.4501.14971441612401.0401.551.2531.861.84.5735354040 66439999
10 AWG10 AWG3377200.51451.140.4881.241291922043041.0401.551.2531.862.05.0835354040 60554301
10 AWG10 AWG4477200.51451.140.5651.441612402593851.0401.551.2531.862.35.8428283232 60686399
8 AWG8 AWG3377300.76601.520.6471.641862773104610.6530.970.7861.172.66.6050505555 64449799

Part numbers in this family (11)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
14 AWG · 3 conductors (1)
6068069914-7 3/C CU THHN/PVC BLACK/RED/BLUE 1x14 GG TYPE TC-ER 600V BLACK14 AWG 3C 7 STRBLACK/RED/BLUECUT TO LENGTH REEL
14 AWG · 4 conductors (1)
6068149914-7 4/C CU THHN/PVC BLACK/RED/BLUE/ORANGE 1x14 GG TYPE TC-ER 600V BLACK14 AWG 4C 7 STRBLACK/RED/BLUE/ORANGECUT TO LENGTH REEL
12 AWG · 3 conductors (3)
6067239912-7 3/C CU THHN/PVC PHASE ID 1X12 GG TYPE TC-ER 600V BLACK12 AWG 3C 7SBLACK/RED/BLUECUT TO LENGTH REEL
6067230112-7 3/C CU THHN/PVC PHASE ID 1X12 GG TYPE TC-ER 600V BLACK 500 FT12 AWG 3C 7SBLACK/RED/BLUE500 FT REEL
6067230212-7 3/C CU THHN/PVC PHASE ID 1X12 GG TYPE TC-ER 600V BLACK 1000 FT12 AWG 3C 7SBLACK/RED/BLUE1000 FT REEL
12 AWG · 4 conductors (1)
6067989912-7 4/C CU THHN/PVC PHASE ID 1x12 GGTYPE TC-ER 600V BLACK12 AWG 4C 7 STRBLACK/RED/BLUE/ORANGECUT TO LENGTH REEL
10 AWG · 2 conductors (1)
6643999910-7 2/C CU THHN/PVC BLACK/RED 1x10 GG TYPE TC-ER 600V BLACK10 AWG 2C 7 STRBLACK/REDCUT TO LENGTH REEL
10 AWG · 3 conductors (2)
6055439910-7 3/C CU THHN/PVC PHASE ID 1x10 GG TYPE TC-ER 600V BLACK10 AWG 3C 7 STRBLACK/RED/BLUECUT TO LENGTH REEL
6055430110-7 3/C CU THHN/PVC PHASE ID 1x10 GG TYPE TC-ER 600V BLACK 500 FT10 AWG 3C 7 STRBLACK/RED/BLUE500 FT REEL
10 AWG · 4 conductors (1)
6068639910-7 4/C CU THHN/PVC PHASE ID 1x10 GG TYPE TC-ER 600V BLACK10 AWG 4C 7 STRBLACK/RED/BLUE/ORANGECUT TO LENGTH REEL
8 AWG · 3 conductors (1)
644497998-7 3/C CU THHN/PVC BLACK/BLUE/RED 1x10 GG TYPE TC-ER 600V BLACK8 AWG 3C 7 STRBLACK/BLUE/REDCUT TO LENGTH REEL

Application & features

Southwire’s 600 Volt Type TC-ER control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 75°C in wet locations and 90°C in dry locations, 105°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 83 Thermoplastic Insulated Wires and Cables
  • UL 1277 Electrical Power and Control Tray Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2
  • ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy