CU 600V PVC-Nylon Insulation PVC Jacket THHN/THWN With Green Ground. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free
- Southwire #
- SPEC45102
Type TC-ER Control Cable 600Volt Copper Conductors, Polyvinyl Chloride (PVC) with nylon layer Insulation THHN/THWN Polyvinyl Chloride (PVC) Jacket with 1 Insulated Green CU Ground, Control Cable Conductor Identification Method 1 Table 2
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (11) ↓Available sizes & constructions
| Cond. Size | Conductor Number | Cond. Strands | Insulation Thickness (mils)(mm) | Jacket Thickness (mils)(mm) | Approx. OD (inches)(cm) | Copper Weight (lbs/1000')(kgs/km) | Approx. Weight (lbs/1000')(kgs/km) | DC Resistance at 25C (ohms/1000')(ohms/km) | AC Resistance at 75C (ohms/1000')(ohms/km) | Min. Bend Radius (in)(cm) | Allowable Ampacity Raceway 75C | Allowable Ampacity Raceway 90C | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 14 AWG14 AWG | 33 | 77 | 150.38 | 451.14 | 0.3490.89 | 5176 | 90134 | 2.6313.92 | 3.1704.72 | 1.43.56 | 2020 | 2525 | 60680699 |
| 14 AWG14 AWG | 44 | 77 | 150.38 | 451.14 | 0.3840.98 | 6495 | 111165 | 2.6313.92 | 3.1704.72 | 1.53.81 | 1616 | 2020 | 60681499 |
| 12 AWG12 AWG | 33 | 77 | 150.38 | 451.14 | 0.3640.92 | 81121 | 131195 | 1.6622.47 | 2.0022.98 | 1.53.81 | 2525 | 3030 | 60672301 |
| 12 AWG12 AWG | 44 | 77 | 150.38 | 451.14 | 0.4061.03 | 101150 | 157234 | 1.6622.47 | 2.0022.98 | 1.64.06 | 2020 | 2424 | 60679899 |
| 10 AWG10 AWG | 22 | 77 | 200.51 | 451.14 | 0.4501.14 | 97144 | 161240 | 1.0401.55 | 1.2531.86 | 1.84.57 | 3535 | 4040 | 66439999 |
| 10 AWG10 AWG | 33 | 77 | 200.51 | 451.14 | 0.4881.24 | 129192 | 204304 | 1.0401.55 | 1.2531.86 | 2.05.08 | 3535 | 4040 | 60554301 |
| 10 AWG10 AWG | 44 | 77 | 200.51 | 451.14 | 0.5651.44 | 161240 | 259385 | 1.0401.55 | 1.2531.86 | 2.35.84 | 2828 | 3232 | 60686399 |
| 8 AWG8 AWG | 33 | 77 | 300.76 | 601.52 | 0.6471.64 | 186277 | 310461 | 0.6530.97 | 0.7861.17 | 2.66.60 | 5050 | 5555 | 64449799 |
Part numbers in this family (11)
| Southwire # | Description | Construction | Conductor Color | Packaging | |
|---|---|---|---|---|---|
| 14 AWG · 3 conductors (1) | |||||
| 60680699 | 14-7 3/C CU THHN/PVC BLACK/RED/BLUE 1x14 GG TYPE TC-ER 600V BLACK | 14 AWG 3C 7 STR | BLACK/RED/BLUE | CUT TO LENGTH REEL | |
| 14 AWG · 4 conductors (1) | |||||
| 60681499 | 14-7 4/C CU THHN/PVC BLACK/RED/BLUE/ORANGE 1x14 GG TYPE TC-ER 600V BLACK | 14 AWG 4C 7 STR | BLACK/RED/BLUE/ORANGE | CUT TO LENGTH REEL | |
| 12 AWG · 3 conductors (3) | |||||
| 60672399 | 12-7 3/C CU THHN/PVC PHASE ID 1X12 GG TYPE TC-ER 600V BLACK | 12 AWG 3C 7S | BLACK/RED/BLUE | CUT TO LENGTH REEL | |
| 60672301 | 12-7 3/C CU THHN/PVC PHASE ID 1X12 GG TYPE TC-ER 600V BLACK 500 FT | 12 AWG 3C 7S | BLACK/RED/BLUE | 500 FT REEL | |
| 60672302 | 12-7 3/C CU THHN/PVC PHASE ID 1X12 GG TYPE TC-ER 600V BLACK 1000 FT | 12 AWG 3C 7S | BLACK/RED/BLUE | 1000 FT REEL | |
| 12 AWG · 4 conductors (1) | |||||
| 60679899 | 12-7 4/C CU THHN/PVC PHASE ID 1x12 GGTYPE TC-ER 600V BLACK | 12 AWG 4C 7 STR | BLACK/RED/BLUE/ORANGE | CUT TO LENGTH REEL | |
| 10 AWG · 2 conductors (1) | |||||
| 66439999 | 10-7 2/C CU THHN/PVC BLACK/RED 1x10 GG TYPE TC-ER 600V BLACK | 10 AWG 2C 7 STR | BLACK/RED | CUT TO LENGTH REEL | |
| 10 AWG · 3 conductors (2) | |||||
| 60554399 | 10-7 3/C CU THHN/PVC PHASE ID 1x10 GG TYPE TC-ER 600V BLACK | 10 AWG 3C 7 STR | BLACK/RED/BLUE | CUT TO LENGTH REEL | |
| 60554301 | 10-7 3/C CU THHN/PVC PHASE ID 1x10 GG TYPE TC-ER 600V BLACK 500 FT | 10 AWG 3C 7 STR | BLACK/RED/BLUE | 500 FT REEL | |
| 10 AWG · 4 conductors (1) | |||||
| 60686399 | 10-7 4/C CU THHN/PVC PHASE ID 1x10 GG TYPE TC-ER 600V BLACK | 10 AWG 4C 7 STR | BLACK/RED/BLUE/ORANGE | CUT TO LENGTH REEL | |
| 8 AWG · 3 conductors (1) | |||||
| 64449799 | 8-7 3/C CU THHN/PVC BLACK/BLUE/RED 1x10 GG TYPE TC-ER 600V BLACK | 8 AWG 3C 7 STR | BLACK/BLUE/RED | CUT TO LENGTH REEL | |
Application & features
Southwire’s 600 Volt Type TC-ER control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 75°C in wet locations and 90°C in dry locations, 105°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.
Standards & references
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- UL 83 Thermoplastic Insulated Wires and Cables
- UL 1277 Electrical Power and Control Tray Cables
- UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
- ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2
- ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
- ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy