DistributorSouthwire

Southwire

CU 600V or 1000V LSZH XHHW-2 SOLONONplus™ Living Building Challenge™ (LBC) Red List Free

Southwire #
SPEC48003

SOLONONplus™ 600Volt or 1000V Single Conductor Copper Cross Linked Polyolefin Low Smoke Zero Halogen (XLPO LSZH) Insulation Type XHHW-2

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (15) ↓

Available sizes & constructions

Cond. SizeCond. StrandsStrand ClassConductor NumberInsulation Thickness (mils)(mm)Approx. OD (inches)(cm)Approx. Weight (lbs/1000')(kgs/km)DC Resistance at 25C (ohms/1000')(ohms/km)Max Pull Tension (lbs)(kg)
10 AWG10 AWG77BB11300.760.1770.4542631.0401.55 67361499
8 AWG8 AWG77BB11451.140.2360.60711060.6530.9713259.87 67356099
6 AWG6 AWG77BB11451.140.2720.691051560.4110.6120994.80 67362999
4 AWG4 AWG77BB11451.140.3190.811582350.2580.38333151.05 67364599
3 AWG3 AWG77BB11451.140.3460.881952900.2050.31420190.51 67388199
2 AWG2 AWG77BB11451.140.3710.942403570.1620.24530240.40 67365299
1/0 AWG1/0 AWG1919BB11551.400.4781.213825680.1020.15844382.83 67366499
2/0 AWG2/0 AWG1919BB11551.400.5221.334737040.0810.121064482.62 67390499
3/0 AWG3/0 AWG1919BB11551.400.5721.455888750.0640.101342608.72 67391799
4/0 AWG4/0 AWG1919BB11551.400.6141.5672910850.0510.081692767.48 67392999
250 KCMIL250 KCMIL3737BB11651.650.6781.7286712900.0430.062000907.18 67394199
350 KCMIL350 KCMIL3737BB11651.650.7771.97119217740.0310.0528001270.06 67395599
500 KCMIL500 KCMIL3737BB11651.650.9022.29167624940.0220.0340001814.37 67397899
600 KCMIL600 KCMIL6161BB11802.031.0342.63203630300.0180.0348002177.24 67399099
2/02/0GreenGreen673896673896

Part numbers in this family (15)

By size:
Southwire #DescriptionConstructionPackaging
10 AWG (1)
6736149910-7 CU 30 MILS XLPO XHHW-2 SOLONONplus VW-1 1000V BLACKMATERIAL BLOCKED OBSOLETE. NO REPLACEMENT MATERIAL #.10 AWG 1C 7SCUT TO LENGTH REEL
8 AWG (1)
673560998-7 CU 45 MILS XLPO XHHW-2 SOLONONplus VW-1 1000V BLACKMATERIAL BLOCKED OBSOLETE. NO REPLACEMENT MATERIAL #.8 AWG 1C 7SCUT TO LENGTH REEL
6 AWG (1)
673629996-7 CU 45 MILS XLPO XHHW-2 SOLONONplus VW-1 1000V BLACKMATERIAL BLOCKED OBSOLETE. NO REPLACEMENT MATERIAL #.6 AWG 1C 7SCUT TO LENGTH REEL
4 AWG (1)
673645994-7 CU 45 MILS XLPO XHHW-2 SOLONONplus VW-1 1000V BLACKMATERIAL BLOCKED OBSOLETE. NO REPLACEMENT MATERIAL #.4 AWG 1C 7SCUT TO LENGTH REEL
3 AWG (1)
673881993-7 CU 45 MILS XLPO XHHW-2 SOLONONplus VW-1 1000V BLACKMATERIAL BLOCKED OBSOLETE. NO REPLACEMENT MATERIAL #.3 AWG 1C 7SCUT TO LENGTH REEL
2 AWG (1)
673652992-7 CU 45 MILS XLPO XHHW-2 SOLONONplus VW-1 1000V BLACKMATERIAL BLOCKED OBSOLETE. NO REPLACEMENT MATERIAL #.2 AWG 1C 7SCUT TO LENGTH REEL
1/0 AWG (1)
673664991/0-19 CU 55 MILS XLPO XHHW-2 SOLONONplus VW-1 1000V BLACKMATERIAL BLOCKED OBSOLETE. NO REPLACEMENT MATERIAL #.1/0 AWG 1C 19SCUT TO LENGTH REEL
2/0 AWG (1)
673904992/0-19 CU 55 MILS XLPO XHHW-2 SOLONONplus VW-1 FT4 1000V BLACKMATERIAL BLOCKED OBSOLETE. NO REPLACEMENT MATERIAL #.2/0 AWG 1C 19SCUT TO LENGTH REEL
3/0 AWG (2)
673917993/0-19 CU 55 MILS XLPO XHHW-2 SOLONONplus VW-1 1000V BLACK3/0 AWG 1C 19SCUT TO LENGTH REEL
679557993/0-19 TINNED CU 55 MILS XLPO XHHW-2 SOLONONplus FT4 600V BLACK3/0 AWG 1C 19SCUT TO LENGTH REEL
4/0 AWG (1)
673929994/0-19 CU 55 MILS XLPO XHHW-2 SOLONONplus VW-1 FT4 1000V BLACKMATERIAL BLOCKED OBSOLETE. NO REPLACEMENT MATERIAL #.4/0 AWG 1C 19SCUT TO LENGTH REEL
250 kcmil (1)
67394199250-37 CU 65 MILS XLPO XHHW-2 SOLONONplus VW-1 1000V BLACKMATERIAL BLOCKED OBSOLETE. NO REPLACEMENT MATERIAL #.250 KCMIL 1C 37SCUT TO LENGTH REEL
350 kcmil (1)
67395599350-37 CU 65 MILS XLPO XHHW-2 SOLONONplus VW-1 1000V BLACKMATERIAL BLOCKED OBSOLETE. NO REPLACEMENT MATERIAL #.350 KCMIL 1C 37SCUT TO LENGTH REEL
500 kcmil (1)
67397899500-37 CU 65 MILS XLPO XHHW-2 SOLONONplus VW-1 FT4 1000V BLACKMATERIAL BLOCKED OBSOLETE. NO REPLACEMENT MATERIAL #.500 KCMIL 1C 37SCUT TO LENGTH REEL
600 kcmil (1)
67399099600-61 CU 80 MILS XLPO XHHW-2 SOLONONplus VW-1 1000V BLACKMATERIAL BLOCKED OBSOLETE. NO REPLACEMENT MATERIAL #.600 KCMIL 1C 61SCUT TO LENGTH REEL

Application & features

Southwire’s 600 Volt or 1000 Volt SOLONONplus™ Type XHHW-2 cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, and aerially when supported by a messenger. These cables are ideal for use in establishments where low smoke and low acid emissions are desired for public safety and health and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.

a. The conductors are available in tinned and flexible copper stranding upon request.
b. NEC compliant
c. The halogen content is less than 0.2% and Acid gas less than 2.0%
d. Passes UL VW-1
e. 70,000 BTU/Hr. Vertical Flame Test
f. UL listed for CT use on 1/0 and Larger
g. UL listed FT4/IEEE 1202 and ST-1 (#2 and larger)
h. -40°C Cold impact and cold bend
i. Oil Resistant I and II
j. UV/Sunlight resistant
k. Color Available upon request
l.PRI oil resistance at 60°C
m.PRII oil resistance at 75°C
n.GRI gasoline and oil resistance
o.GRII gasoline and oil resistance
p. REACH & RoHS compliant
q. Listed and marked HAL-FREE (Halogen Free) per CSA 2556-15
r. Living Building Challenge™ (LBC) Red List Free

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B170 Oxygen Free Electrolytic Copper (available upon request)
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • UL 2885 Acid Gas, Acidity and conductivity of combusted materials and assessment of halogens
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • ICEA T-33-655/MIL-C-24643 Low Smoke Halogen Free (LSHF) Polymeric Jackets
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • RoHS-2 (European Directive 2011/65/EU)
  • ISO 9001 Quality management
  • ISO 14001 Environmental management systems standard
  • NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (2 AWG and larger)
  • NFPA 502 Standard for Road Tunnels, Bridges, and Other Limited Access Highways (non-emergency circuits only)