DistributorSouthwire

Southwire

CU 600V EPR Insulation Thermoset LSZH-TS Jacket RHH/RHW-2. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free

Southwire #
SPEC45006

Power Cable 600Volt Single Conductor Copper, Ethylene Propylene Rubber (EPR) insulation RHH/RHW-2 USE-2 Thermoset SOLONON® Low Smoke Zero Halogen (LSZH-TS) Jacket. CT Rated 1/0 and Larger - Silicone Free

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (28) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Copper Weight (lbs/1000')(kgs/km)Approx. Weight (lbs/1000')(kgs/km)
8 AWG8 AWG11770.1410.36451.14150.380.2680.68507474110 89066001
6 AWG6 AWG11770.1770.45451.14300.760.3380.8681121119177 89065999
2 AWG2 AWG11770.2820.72451.14300.760.4381.11204304258384 55108801
1/0 AWG1/0 AWG1119190.3610.92551.40451.140.5751.46326485418622 56156101
2/0 AWG2/0 AWG1119190.4051.03551.40451.140.6171.57410610511760 56156099
3/0 AWG3/0 AWG1119190.4561.16551.40451.140.6691.70518771628935 58179999
4/0 AWG4/0 AWG1119190.5121.30551.40451.140.7111.816539727701146 56155601
250 KCMIL250 KCMIL1137370.5581.42651.65651.650.8172.0877111479441405 56155499
350 KCMIL350 KCMIL1137370.6611.68651.65651.650.9162.331080160712801905 56155301
500 KCMIL500 KCMIL1137370.7892.00651.65651.651.0412.641543229617752641 89065801
750 KCMIL750 KCMIL1161610.9682.46802.03651.651.2463.162315344526253906 55109199
8 AWG8 AWG111.02.5413259.870.6530.970.7861.170.0520.0850505555 89066001
6 AWG6 AWG111.33.3020994.800.4110.610.4950.740.0510.0865657575 89065999
2 AWG2 AWG111.74.32530240.400.1620.240.1950.290.0450.07115115130130 55108801
1/0 AWG1/0 AWG112.35.84844382.830.1020.150.1220.180.0440.07150150170170 56156101
2/0 AWG2/0 AWG112.46.101064482.620.0810.120.0970.140.0430.06175175195195 56156099
3/0 AWG3/0 AWG112.66.601342608.720.0640.100.0780.120.0420.06200200225225 58179999
4/0 AWG4/0 AWG112.87.111692767.480.0510.080.0620.090.0410.06230230260260 56155601
250 KCMIL250 KCMIL113.28.132000907.180.0430.060.0530.080.0410.06255255290290 56155499
350 KCMIL350 KCMIL113.69.1428001270.060.0310.050.0390.060.0400.06310310350350 56155301
500 KCMIL500 KCMIL115.213.2140001814.370.0220.030.0290.040.0390.06380380430430 89065801
750 KCMIL750 KCMIL116.215.7560002721.550.0140.020.0220.030.0380.06475475535535 55109199

Part numbers in this family (28)

By size:
Southwire #DescriptionConstructionPackaging
8 AWG (2)
890660998-7 CU 45 EPR/15 LSZH 600V RHH/RHW-2 BLACK8 AWG 1C 7SCUT TO LENGTH REEL
890660018-7 CU 45 EPR/15 LSZH 600V RHH/RHW-2 BLACK 500 FT8 AWG 1C 7S500 FT REEL
6 AWG (1)
890659996-7 CU 45 EPR/30 LSZH 600V RHH/RHW-2 BLACK6 AWG 1C 7SCUT TO LENGTH REEL
2 AWG (4)
551088992-7 CU 45 EPR/30 LSZH 600V RHH/RHW-2/USE-2 BLACK2 AWG 1C 7SCUT TO LENGTH REEL
551088022-7 CU 45 EPR/30 LSZH 600V RHH/RHW-2/USE-2 BLACK 1000 FT2 AWG 1C 7S1000 FT REEL
551088032-7 CU 45 EPR/30 LSZH 600V RHH/RHW-2/USE-2 BLACK 2000 FT2 AWG 1C 7S2000 FT REEL
551088012-7 CU 45 EPR/30 LSZH 600V RHH/RHW-2/USE-2 BLACK 2500 FT2 AWG 1C 7S2500 FT REEL
1/0 AWG (3)
561561991/0-19 CU 55 EPR/45 LSZH 600V RHH/RHW-2/USE-2 BLACK1/0 AWG 1C 19SCUT TO LENGTH REEL
561561011/0-19 CU 55 EPR/45 LSZH 600V RHH/RHW-2/USE-2 BLACK 1000 FT1/0 AWG 1C 19S1000 FT REEL
561561021/0-19 CU 55 EPR/45 LSZH 600V RHH/RHW-2/USE-2 BLACK 500 FT1/0 AWG 1C 19S500 FT REEL
2/0 AWG (1)
561560992/0-19 CU 55 EPR/45 SOLONON 600V RHW-2 USE-22/0 AWG 1C 19SCUT TO LENGTH REEL
3/0 AWG (1)
581799993/0-19 CU 55 EPR/45 LSZH 600V RHH/RHW-2/USE-2 BLACK3/0 AWG 1C 19SCUT TO LENGTH REEL
4/0 AWG (6)
561556994/0-19 CU 55 EPR/45 LSZH 600V RHH/RHW-2/USE-2 BLACK4/0 AWG 1C 19SCUT TO LENGTH REEL
561556024/0-19 CU 55 EPR/45 LSZH 600V RHH/RHW-2/USE-2 BLACK 1000 FT4/0 AWG 1C 19S1000 FT REEL
561556014/0-19 CU 55 EPR/45 LSZH 600V RHH/RHW-2/USE-2 BLACK 2000 FT4/0 AWG 1C 19S2000 FT REEL
599582994/0-19 TINNED CU 55 EPR/45 LSZH 600V RHH/RHW-2/USE-2 BLACK4/0 AWG 1C 19SCUT TO LENGTH REEL
599582014/0-19 TINNED CU 55 EPR/45 LSZH 600V RHH/RHW-2/USE-2 BLACK 2000 FT4/0 AWG 1C 19S2000 FT REEL
599582024/0-19 TINNED CU 55 EPR/45 LSZH 600V RHH/RHW-2/USE-2 BLACK 500 FT4/0 AWG 1C 19S500 FT REEL
250 kcmil (1)
56155499250-37 CU 65 EPR/65 LSZH 600V RHH/RHW-2/USE-2 BLACK250 KCMIL 1C 37SCUT TO LENGTH REEL
350 kcmil (2)
56155399350-37 CU 65 EPR/65 LSZH 600V RHH/RHW-2/USE-2 BLACK350 KCMIL 1C 37SCUT TO LENGTH REEL
56155301350-37 CU 65 EPR/65 LSZH 600V RHH/RHW-2/USE-2 BLACK 1000 FT350 KCMIL 1C 37S1000 FT REEL
500 kcmil (6)
89065899500-37 CU 65 EPR/65 LSZH 600V RHH/RHW-2/USE-2 BLACK500 KCMIL 1C 37SCUT TO LENGTH REEL
89065804500-37 CU 65 EPR/65 LSZH 600V RHH/RHW-2/USE-2 BLACK 1000 FT500 KCMIL 1C 37S1000 FT REEL
89065805500-37 CU 65 EPR/65 LSZH 600V RHH/RHW-2/USE-2 BLACK 1000 FT500 KCMIL 1C 37S1000 FT REEL
89065801500-37 CU 65 EPR/65 LSZH 600V RHH/RHW-2/USE-2 BLACK 1800 FT500 KCMIL 1C 37S1800 FT REEL
89065803500-37 CU 65 EPR/65 LSZH 600V RHH/RHW-2/USE-2 BLACK 1800 FT500 KCMIL 1C 37S1800 FT REEL
89065825500-37 CU 65 EPR/65 LSZH 600V RHH/RHW-2/USE-2 BLACK 2000 FT500 KCMIL 1C 37S2000 FT REEL
750 kcmil (1)
55109199750-61 CU 80 EPR/65 LSZH 600V RHH/RHW-2/USE-2 BLACK750 KCMIL 1C 61SCUT TO LENGTH REEL

Application & features

Southwire’s 600 Volt power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. CT Rated 1/0 and Larger - Silicone Free

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • CT USE Sizes 1/0 AWG and Larger