DistributorSouthwire

Southwire

CU 600/1000V XLPE Insulation PVC Jacket XHHW-2 With Green Ground. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free

Southwire #
SPEC45104

Type TC-ER Control Cable 600 or 1000 Volt Copper Conductors, Cross Linked Polyethylene (XLPE) Insulation XHHW-2 Polyvinyl Chlo- ride (PVC) Jacket with 1 Insulated Green CU Ground

Priced by quote — copper moves daily (COMEX), so we quote at the current price.

Part numbers in this family (6) ↓

Available sizes & constructions

Cond. SizeConductor NumberCond. StrandsDiameter Over Conductor (in)(cm)Insulation Thickness (mils)(mm)Jacket Thickness (mils)(mm)Approx. OD (inches)(cm)Copper Weight (lbs/1000')(kgs/km)Approx. Weight (lbs/1000')(kgs/km)DC Resistance at 25C (ohms/1000')(ohms/km)AC Resistance at 75C (ohms/1000')(ohms/km)Min. Bend Radius (in)(cm)Allowable Ampacity Raceway 75CAllowable Ampacity Raceway 90C
14 AWG14 AWG2277300.76451.140.3530.903857881312.6313.923.1704.721.43.5620202525 67169999
12 AWG12 AWG2277300.76451.140.4121.0561911191771.6622.472.0022.981.64.0625253030 59639799
10 AWG10 AWG2277300.76451.140.4761.21971441682501.0401.551.2531.861.94.8335354040 59283199
8 AWG8 AWG2277451.14601.520.6361.621341992463660.6530.970.7861.172.56.3550505555 45909899
6 AWG6 AWG22770.1780.45451.14601.520.7141.811341993465150.4110.610.4950.742.97.3765657575 45824399
4 AWG4 AWG2277451.14601.520.8152.073124644666930.2580.380.3200.483.38.3885859595 45815199

Part numbers in this family (6)

By size:
Southwire #DescriptionConstructionConductor ColorPackaging
6716999914-7 2/C CU XHHW/PVC PHASE ID 1x14 GG TYPE TC-ER 1000V BLACK14 AWG 2C 7 STRBLACK/WHITECUT TO LENGTH REEL
5963979912-7 2/C CU XHHW/PVC BLACK/WHITE 1x12 GG TYPE TC-ER 1000V BLACK12 AWG 2C 7 STRBLACK/WHITECUT TO LENGTH REEL
5928319910-7 2/C CU XHHW/PVC BLACK/WHITE 1x10 GG TYPE TC-ER 1000V BLACK10 AWG 2C 7 STRBLACK/WHITECUT TO LENGTH REEL
459098998-7 2/C CU XHHW/PVC BLACK/WHITE 1X#10 GG TYPE TC-ER 1000V BLACK8 AWG 2C 7 STRBLACK/WHITECUT TO LENGTH REEL
458243996-7 2/C CU XHHW/PVC BLACK/WHITE 1X#8 GG TYPE TC-ER 1000V BLACK6 AWG 2C 7 STRBLACK/WHITECUT TO LENGTH REEL
458151994-7 2/C CU XHHW/PVC BLACK/WHITE 1X#8 GG TYPE TC-ER 1000V BLACK4 AWG 2C 7 STRBLACK/WHITECUT TO LENGTH REEL

Application & features

Southwire’s 600 or 1000 Volt Type TC-ER control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of op- erating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 conductors are listed for exposed runs (TC-ER) per NEC 336.10.

Standards & references

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1277 Electrical Power and Control Tray Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test