CU 600/1000V XLPE Insulation PVC Jacket XHHW-2 With Green Ground. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free
- Southwire #
- SPEC45104
Type TC-ER Control Cable 600 or 1000 Volt Copper Conductors, Cross Linked Polyethylene (XLPE) Insulation XHHW-2 Polyvinyl Chlo- ride (PVC) Jacket with 1 Insulated Green CU Ground
Priced by quote — copper moves daily (COMEX), so we quote at the current price.
Part numbers in this family (6) ↓Available sizes & constructions
| Cond. Size | Conductor Number | Cond. Strands | Diameter Over Conductor (in)(cm) | Insulation Thickness (mils)(mm) | Jacket Thickness (mils)(mm) | Approx. OD (inches)(cm) | Copper Weight (lbs/1000')(kgs/km) | Approx. Weight (lbs/1000')(kgs/km) | DC Resistance at 25C (ohms/1000')(ohms/km) | AC Resistance at 75C (ohms/1000')(ohms/km) | Min. Bend Radius (in)(cm) | Allowable Ampacity Raceway 75C | Allowable Ampacity Raceway 90C | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 14 AWG14 AWG | 22 | 77 | 300.76 | 451.14 | 0.3530.90 | 3857 | 88131 | 2.6313.92 | 3.1704.72 | 1.43.56 | 2020 | 2525 | 67169999 | |
| 12 AWG12 AWG | 22 | 77 | 300.76 | 451.14 | 0.4121.05 | 6191 | 119177 | 1.6622.47 | 2.0022.98 | 1.64.06 | 2525 | 3030 | 59639799 | |
| 10 AWG10 AWG | 22 | 77 | 300.76 | 451.14 | 0.4761.21 | 97144 | 168250 | 1.0401.55 | 1.2531.86 | 1.94.83 | 3535 | 4040 | 59283199 | |
| 8 AWG8 AWG | 22 | 77 | 451.14 | 601.52 | 0.6361.62 | 134199 | 246366 | 0.6530.97 | 0.7861.17 | 2.56.35 | 5050 | 5555 | 45909899 | |
| 6 AWG6 AWG | 22 | 77 | 0.1780.45 | 451.14 | 601.52 | 0.7141.81 | 134199 | 346515 | 0.4110.61 | 0.4950.74 | 2.97.37 | 6565 | 7575 | 45824399 |
| 4 AWG4 AWG | 22 | 77 | 451.14 | 601.52 | 0.8152.07 | 312464 | 466693 | 0.2580.38 | 0.3200.48 | 3.38.38 | 8585 | 9595 | 45815199 |
Part numbers in this family (6)
| Southwire # | Description | Construction | Conductor Color | Packaging | |
|---|---|---|---|---|---|
| 67169999 | 14-7 2/C CU XHHW/PVC PHASE ID 1x14 GG TYPE TC-ER 1000V BLACK | 14 AWG 2C 7 STR | BLACK/WHITE | CUT TO LENGTH REEL | |
| 59639799 | 12-7 2/C CU XHHW/PVC BLACK/WHITE 1x12 GG TYPE TC-ER 1000V BLACK | 12 AWG 2C 7 STR | BLACK/WHITE | CUT TO LENGTH REEL | |
| 59283199 | 10-7 2/C CU XHHW/PVC BLACK/WHITE 1x10 GG TYPE TC-ER 1000V BLACK | 10 AWG 2C 7 STR | BLACK/WHITE | CUT TO LENGTH REEL | |
| 45909899 | 8-7 2/C CU XHHW/PVC BLACK/WHITE 1X#10 GG TYPE TC-ER 1000V BLACK | 8 AWG 2C 7 STR | BLACK/WHITE | CUT TO LENGTH REEL | |
| 45824399 | 6-7 2/C CU XHHW/PVC BLACK/WHITE 1X#8 GG TYPE TC-ER 1000V BLACK | 6 AWG 2C 7 STR | BLACK/WHITE | CUT TO LENGTH REEL | |
| 45815199 | 4-7 2/C CU XHHW/PVC BLACK/WHITE 1X#8 GG TYPE TC-ER 1000V BLACK | 4 AWG 2C 7 STR | BLACK/WHITE | CUT TO LENGTH REEL |
Application & features
Southwire’s 600 or 1000 Volt Type TC-ER control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of op- erating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 conductors are listed for exposed runs (TC-ER) per NEC 336.10.
Standards & references
- ASTM B3 Soft or Annealed Copper Wire
- ASTM B8 Concentric-Lay-Stranded Copper Conductors
- UL 44 Thermoset-Insulated Wires and Cables
- UL 1277 Electrical Power and Control Tray Cables
- UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
- ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
- ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
- IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test